MDS SCIEX 4000 QTrap
Objektnummer | B00017665 |
---|---|
Seriennummer | 017665 |
Nome oggetto | MDS SCIEX 4000 QTrap |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : MDS Sciex
model : 4000 QTrap
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
The 4000 Q TRAP® LC/MS/MS System is a hybrid triple quadrupole/linear ion trap mass spectrometer. Ideal for drug discovery and development, metabolite identification and proteomic applications including post-translationally modified proteins discovery, protein identification, and biomarker validation.
- Enables high-sensitivity full-scan MS, MS/MS, and MS3 with high-selectivity from true triple quadrupole precursor ion (PI) and neutral loss (NL) scans.
- Perform multiple reaction monitoring (MRM) for quantitation using high-sensitivity triple quadrupole.
- Identify, characterize, and quantitate metabolites more quickly and easily.
- Identify and sequence post-translationally modified (PTM) peptides automatically in a single LC/MS/MS run.
- Facilitates hypothesis-driven biomarker discovery and validation.
Innovation in Linear Ion Trap Technology
Applied Biosystems/MDS SCIEX Linear Ion Trap (LIT) technology enables unmatched quantitative and qualitative performance within a single system. Use of a quadrupole as a linear ion trap significantly enhances ion trap performance by increasing ion capacity, improving injection and trapping efficiencies, and increasing duty cycle. With the unequalled sensitivity of the API 4000 system, the 4000 Q TRAP® system brings LIT technology together with the leading triple quadrupole for drug development.
A Complete, Flexible, Integrated System
The 4000 Q TRAP® system fits seamlessly into your lab's workflow and boosts your discovery productivity. Together with our powerful Analyst® software, this system offers a full complement of features to simplify every aspect of methods development, data acquisition and processing, including flexible control of popular LC platforms and
21 CFR Part 11 compliance
. The system design enables plug-and-play sources to accommodate a wide range of applications and flow rates. Finally, you can pull it all together with advanced application software, including Metabolite ID, BioAnalyst, Pro ID, Pro BLAST, Pro ICAT, Fragment Interpretation, Library Searching, and Automaton, so you can obtain more useful information per sample than any other single system.
More Metabolites in Less Time
The 4000 Q TRAP® system's high quantitative sensitivity and highly specific scan functions enable you to rapidly, identify and characterize even low-abundance metabolites in a single run. And because this system can trigger MS/MS and MS
3
from MRM transitions, you can confirm the presence and structure of metabolites at the same time. So what used to take you multiple analyses on multiple MS platforms, now only takes a single LC/MS/MS run on a single system.
Automated PTM Discovery in a Single Run
Automating PTM analysis is easy using this system's Information Dependent Acquisition (IDA) software, which links highly specific PI and NL scan functions to identify PTMs with high-sensitivity MS/MS scans to determine the modification sites. With the addition of our advanced application software, you have everything you need for automated PTM discovery from a single LC/MS/MS run.
Validate Discovered Protein Biomarkers
Unique MIDASTM workflow enables high throughput validation and quantitation of protein biomarkers discovered through genomic or proteomic experiements.
Performance/Throughput |
|
TurboIonSpray® probe flow rate range |
5 to 3000 μL/min |
APCI probe flow rate range |
200 to 3000 μL/min |
Performance |
|
Dynamic Range |
1 cps to 4 x 10 6 cps (pulse counting) |
Scan speed |
User-settable scan speeds of 250 amu/sec, 1000 amu/sec and 4,000 amu/sec in linear ion trap mode. Maximum of 2,400 amu/sec in RF/DC mode |
NanoSpray source with the MicroIonSpray® head flow rate range |
0.05 to 2.0 μL/min |
Mass Range |
m/z of 5 to 2800 in Q1/Q3 RF/DC mode, m/z of 50 to 2800 in linear ion trap mode |
NanoSpray source using the continuous NanoSpray head flow rate |
0.05 to 0.5 μL/min |
NanoSpray source with discrete NanoSpray head flow rate |
0.02 to 0.05 μl/min |
Mass Stability |
At vacuum and electronics equilibrium, 0.1 amu over 9 hrs at m/z 2010 with normal operating temperature |
Mass Resolution |
>3000 at m/z 609 at 250 amu/sec |
Physical Specifications |
|
Width |
130 cm (53 in) |
Depth |
50 cm (20 in) |
Weight |
136 kg (299 lb) |
Height |
52 cm (21.5 in) |
Computer Requirements (PC) |
|
Operating System |
Windows 2000 |
CD-ROM |
40x/10x/40x CDRW |
Floppy |
1.44 MB |
Memory |
256 MB |
CPU |
2.53 GHz |
Hard Disk |
40 GB |
Display |
18 inches Viewable Flat Panel Monitor recommended |
Power Requirements |
|
Power Consumption |
2500VA max |
Voltage |
2 separate 208V minimum to 242 V maximum |
Frequency Hz |
50/60 Hz |
Circuit Current |
15A grounded single-phase circuit |