Macherey-Nagel Nanocolor 500D
Objektnummer | B00018228 |
---|---|
Seriennummer | 018228 |
Nome oggetto | Macherey-Nagel Nanocolor 500D |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Machery + Nagel
model : Nanocolor 500 D
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Digitalphotometer NANOCOLOR® 500 D |
Mircoprocessor controled filter photometer |
The digital photometer NANOCOLOR® 500 D is the consequent development of our very successful photometer NANOCOLOR® 400 D. Adapted to our customers requirements, today and tomorrow, it is suitable for universal use in water and wastewater analysis. This includes municipal and industrial wastewater, drinking water, surface water, ground water as well as cooling and boiler water. |
Save time and make your lab time easier
Fast measurements by NANOCOLOR® barcode technology
- Fully automatic, instant cuvette detection by the built-in laser scanner allows simple and fast routine analysis
- Selection of the test method and suitable wavelength, the actual measurement and storage of the measurement results are carried out automatically without having to use any other key
Measurement without cuvette slot cover
- The modern designed optics is insensitive to external light and allows straightforward measurements
Everything at a glance
- The modern, illuminated graphic display with user guidance shows all the important data at a glance.
Pre-programmed tests and photometric basic functions
- More than 100 pre-programmed tests with over 200 analysis programmes
- Straightforward call-up of all photometric basic functions, such as absorbance, factor, standard, transmission and kinetics
Experience precision and increase accuracy
Self-explanatory user guidance
- All tests and menu items can be activated fast and easily. The photometer can be operated without any complex and time-consuming training
Manual with test instructions, presented as pictograms
- Safe test procedures without complex instructions
Highly accurate measurements by high-quality optical components
- The high-precision optic warrented accurate results
Assure results and meet specifications
IQC according to ISO 9001 with NANOCONTROL NANOCHECK
- Conformance to requirements of internal quality control (IQC) and protection towards supervisors and authorities
-
Fast and easy control of photometric accuracy of the NANOCOLOR® 500 D with NANOCONTROL NANOCHECK
(Cat. No. 925 701) by the user himself - Documentation of results in accordance to GLP
- Individual entries of sample number, sample location, user and dilution
- Clear memory management
- GLP-conform storage of the measured results with all supplementary information such as date, time, sample number, sample location, user and dilution
- Fast and easy access to stored results and data sets
- Convenient export of data
- Easy transfer of measured results and spectra to various common PC formats (e.g. MS Excel)
- Direct print-out of measured data with the NANOCOLOR® thermal printer (Cat. No. 919 16)
Enjoy flexibility and be prepared for the future
No cuvette adapter required
- Round tubes (16 mm OD) and rectangular cuvettes (10, 20, 50 mm) can be used in the universal cuvette slot without any adapter
- Small accessories are not required
Programmable for user defined applications
- Free programming of up to 100 user defined methods
Fast photometer update - free of charge
- At any time, stay up-to-date by easy programme updating via Internet/PC
In the field and in the lab
The
standard built-in, robust high-performance battery with charge regulator allows continuous operation at 220V (110V) and up to 3000 on-site mains-independent measurements.
The battery charge status is shown in the graphic display. In the power saving mode, the photometer switches off automatically after 10, 20
120 min.
Technical data |
|
Type: |
Filter photometer with microprocessor control, self-test and auto-calibration |
Light sources: |
Tungsten lamp |
Optical system: |
Automatic filter wheel with 10 interference filters |
Wavelength: |
345 / 365 / 436 / 470 / 520 / 540 / 585 / 620 / 690 / 800 nm |
Wavelength accuracy: |
± 2 nm |
Wavelength calibration: |
Automatic |
Wavelength selection: |
Automatic, barcode |
Spectral bandwidth: |
10 12 nm |
Photometric range: |
± 3.0 E |
Measuring modes: |
More than 100 pre-programmed tests, 100 optionally programmable methods, absorbance, transmission, factor, kinetics |
Cuvette holder: |
round tubes 14 mm ID, rectangular cuvettes 10, 20, 50 mm |
Data memory: |
500 measured data sets, GLP conform |
Display: |
graphic display, backlight, 64 x 128 pixels |
Operation: |
bar code technology, display user guidance, foil-covered push-buttons |
External light: |
Insensitive, open cuvette slot |
Interfaces: |
USB 1.1 and bidirectional serial RS 232 |
Update: |
Via Internet / PC |
Operating range: |
10-50 °C , max. 90% relative humidity (without condensation) |
Power supply: |
100 240V~, 50/60 Hz / 6V, 3.2 Ah via built-in battery with charge regulator and mains power supply |
DimensionsL / B / H: |
227 x 282 x 105 mm |
Weight: |
2,4 kg |
Warranty: |
2 years |
This appliance comply with the following EC directives: |
|
|
|