Archivio

Macherey-Nagel Nanocolor 500D

Seriennummer: 018228
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00018228
Seriennummer 018228
Nome oggetto Macherey-Nagel Nanocolor 500D
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Machery + Nagel

model :                   Nanocolor 500 D

annotation :           Dokumente engl.

 

 

 

Digitalphotometer NANOCOLOR® 500 D

Mircoprocessor controled filter photometer

The digital photometer NANOCOLOR® 500 D is the consequent development of our very successful photometer NANOCOLOR® 400 D. Adapted to our customers’ requirements, today and tomorrow, it is suitable for universal use in water and wastewater analysis. This includes municipal and industrial wastewater, drinking water, surface water, ground water as well as cooling and boiler water.

 

 

Save time and make your lab time easier

Fast measurements by NANOCOLOR® barcode technology

  • Fully automatic, instant cuvette detection by the built-in laser scanner allows simple and fast routine analysis
  • Selection of the test method and suitable wavelength, the actual measurement and storage of the measurement results are carried out automatically without having to use any other key

Measurement without cuvette slot cover

  • The modern designed optics is insensitive to external light and allows straightforward measurements

Everything at a glance

  • The modern, illuminated graphic display with user guidance shows all the important data at a glance.

Pre-programmed tests and photometric basic functions

  • More than 100 pre-programmed tests with over 200 analysis programmes
  • Straightforward call-up of all photometric basic functions, such as absorbance, factor, standard, transmission and kinetics

 

 

Experience precision and increase accuracy

Self-explanatory user guidance

  • All tests and menu items can be activated fast and easily. The photometer can be operated without any complex and time-consuming training

Manual with test instructions, presented as pictograms

  • Safe test procedures without complex instructions

Highly accurate measurements by high-quality optical components

  • The high-precision optic warrented accurate results

 

 

Assure results and meet specifications

IQC according to ISO 9001 with NANOCONTROL NANOCHECK

  • Conformance to requirements of internal quality control (IQC) and protection towards supervisors and authorities
  • Fast and easy control of photometric accuracy of the NANOCOLOR® 500 D with NANOCONTROL NANOCHECK
    (Cat. No. 925 701) by the user himself
  • Documentation of results in accordance to GLP
  • Individual entries of sample number, sample location, user and dilution
  • Clear memory management
  • GLP-conform storage of the measured results with all supplementary information such as date, time, sample number, sample location, user and dilution
  • Fast and easy access to stored results and data sets
  • Convenient export of data
  • Easy transfer of measured results and spectra to various common PC formats (e.g. MS Excel)
  • Direct print-out of measured data with the NANOCOLOR® thermal printer (Cat. No. 919 16)

 

 

Enjoy flexibility and be prepared for the future

No cuvette adapter required

  • Round tubes (16 mm OD) and rectangular cuvettes (10, 20, 50 mm) can be used in the universal cuvette slot without any adapter
  • Small accessories are not required

Programmable for user defined applications

  • Free programming of up to 100 user defined methods

Fast photometer update - free of charge

  • At any time, stay up-to-date by easy programme updating via Internet/PC

In the field and in the lab
The standard built-in, robust high-performance battery with charge regulator allows continuous operation at 220V (110V) and up to 3000 on-site mains-independent measurements. The battery charge status is shown in the graphic display. In the power saving mode, the photometer switches off automatically after 10, 20… 120 min.

 

 

Technical data

 

Type:

Filter photometer with microprocessor control, self-test and auto-calibration

Light sources:

Tungsten lamp

Optical system:

Automatic filter wheel with 10 interference filters

Wavelength:

345 / 365 / 436 / 470 / 520 / 540 / 585 / 620 / 690 / 800 nm
plus 2 compartments for additional filters

Wavelength accuracy:

± 2 nm

Wavelength calibration:

Automatic

Wavelength selection:

Automatic, barcode

Spectral bandwidth:

10 – 12 nm

Photometric range:

± 3.0 E

Measuring modes:

More than 100 pre-programmed tests, 100 optionally programmable methods, absorbance, transmission, factor, kinetics

Cuvette holder:

round tubes 14 mm ID, rectangular cuvettes 10, 20, 50 mm

Data memory:

500 measured data sets, GLP conform

Display:

graphic display, backlight, 64 x 128 pixels

Operation:

bar code technology, display user guidance, foil-covered push-buttons

External light:

Insensitive, open cuvette slot

Interfaces:

USB 1.1 and bidirectional serial RS 232

Update:

Via Internet / PC

Operating range:

10-50 °C , max. 90% relative humidity (without condensation)

Power supply:

100 – 240V~, 50/60 Hz / 6V, 3.2 Ah via built-in battery with charge regulator and mains power supply

DimensionsL / B / H:

227 x 282 x 105 mm

Weight:

2,4 kg

Warranty:

2 years

This appliance comply with the following EC directives:
– 73/23/EEC of 19.02.1973 – Low-Voltage Directive
– 89/336/EEC of 03.05.89 (including amendment directive 92/31/EEC) – EMC Directive

 

 

 

Gruppo prodotti: Fotometri / Spettrofotometri

Non è stato trovato alcun prodotto corrispondente alla selezione.