Macherey-Nagel Nanocolor 300D
Objektnummer | B00013579 |
---|---|
Seriennummer | 013579 |
Nome oggetto | Macherey-Nagel Nanocolor 300D |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Filter photometer NANOCOLOR® 300 D
The NANOCOLOR® 300 D is not only a high-performance filter photometer, it also features versatile software capabilities. With its arge reserves of light at all wavelengths, the user can perform precise measurements, even at high extinctions.
Storage of all NANOCOLOR® analytical methods and multilingual user guidance facilitate measurement. Additional programmes such as measurement of extinction, kinetics, data networks, etc. expand the applicability beyond the NANOCOLOR® analytical system as an instrument which can be used in all types of application in the laboratory.
Additional features are: processing of non-linear curves, storage of measurement results, warning for values outside the measuring range, possibility of programming the user's own analytical procedures, etc.
Technical data
Single beam filter photometer for a wavelength range from 340 to 860 nm Silicon photo-element
Automatic zero adjustment
Display: 2 lines of 16 characters each, 8 mm high
Foil-covered keys with input verification
Cuvettes: rectangular cuvettes 10, 20 and 50 mm
round glass tubes 14 mm ID
Photometric accuracy: ± 1%
Long-term stability: < 0.002 E/h
Power requirements: 9 V, max. 0.7 A
Power consumption: 4 VA
Data interfaces: bidirectional RS 232 C interface
Centronics interface for a printer Dimensions: 210 x 260 x 95 mm
Weight:2.1 kg
1 display of method number
2 2-line display
3 20-part keyboard
4 plug-in slot for magnetic cards
5 cuvette slot with automatic cuvette identification
6 socket for connection of mains adaptor
7 plug-in slot for the PROM card
8 RS232 C interface
9 Centronics parallel interface
10 reset key
Digital display
An alphanumeric display serves for user guidance and results. lt contains two lines with 16 characters each. Height of characters is 8 mm.
Optical construction
light source cuvette filter photo cell Computer display
Light source: lamp, which emits light in the wavelength range 340 860 nm
Cuvette: measurement vessel with the analysis sample
Interference absorbs the entire spectrum of light except for the wavelength
filter: required for the analysis and reflects dispersed light and thermal radiation
Photo cell: converts the light transmitted through the test sample into electric current
Computer: converts the electric Signal into a digital reading using the characteristic data for the respective test
Display: user guidance and display of results
Filters and filter wheel
As the tungsten lamp generates light within the spectral range of 340 - 860 nm, filters are used which only transmit light of the wavelength, which is absorbed by the analysis sample. Light which is practically monochromatic can be attained with the interference filters used in the NANOCOLOR® 300 D. This quality of light ensures a high level of sensitivity and a greater accuracy in the analytical results. The increase in extinction per rise in concentration is also near the maximum value possible.
There are 10 filters fitted in a filter wheel with 12 slots. All of the NANOCOLOR® methods can be evaluated using these filters. The wheel also features two spare filter slots in case the user needs to fit additional filters. Once the method is called up, the filter wheel automatically turns the required filter into the path of the beam.
If new methods are adopted, or if existing methods are modified, other filters can be incorporated into the measurement programme at any time.
Interference filters are heat-sensitive and are metal-coated towards the light source.
When the photometer NANOCOLOR® 300 D is switched on, it automatically performs a filter test. If a deviation is found, the programme asks for a new calibration. Filters which have left the confidence interval, are displayed as <error: filter> (filter change is necessary). In order to prevent wrong measurements, further evaluation of tests which require the defective filter is blocked.
Filter position |
Wavelength of the Iight a [nm] |
HW b [nm] |
Colour of the light/filter |
Colour impression (reaction colour) |
1 |
345 ° |
60 |
ultraviolet |
not visible |
2 |
385 |
16 |
deep violet |
not visible |
3 |
436 |
12 |
violet |
yellow |
4 |
470 |
10 |
blue |
orange |
5 |
520 |
11 |
blue-green |
magenta |
6 |
540 |
11 |
green |
red-violet |
7 |
585 |
10 |
orange |
blue-violet |
8 |
620 |
10 |
red |
blue |
9 |
690 |
10 |
Jeep red |
Jeep blue |
10 |
800 |
10 |
infrared |
black |
a Interference filters: ± 2 nm; b HW = band width at half transmission
c coloured glass filter