Jasco Report - 100
| Objektnummer | B00012181 |
|---|---|
| Seriennummer | 012181 |
| Nome oggetto | Jasco Report - 100 |
| Stato | Archived Product |
Gruppo prodotti: Spettrometri Infrarosso
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Jasco
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Das JASCO IR Report 100 ist ein dispergierendes Infrarotspektrometer. Einfache Handhabung verbunden mit Leistungen, die im Bereich der Forschung gefordert werden, sowie der geringe Preis sind die Hauptmerkmale dieses Infrarot-Spektrometers.
Leistungen
Das IR Report 100 erfaßt den Wellenzahlbereich von 4000 bis 800 cm -1 . Zwei Gitter werden durch Computer gesteuerte Stepper-Motoren bewegt, wodurch eine bessere Wellenzahlgenauigkeit und Wiederholbarkeit erreicht wird.
Die Computer gesteuerte Spektrenaufnahme über den gesamten Wellenzahlbereich dauert nur 4 Minuten bei Beibehaltung besserer Auflösung. Die Zweistrahlmessung verbunden mit Mikroprozessor gesteuerter Datenaufnahme gewährt zuverlässigen Betrieb für eine große Anzahl an Analysen.
Eingebauter Thermoplotter
Der integrierte Thermoplotter/printer liefert eine qualitativ hochwertige Hardkopie-Ausgabe der aufgenommenen Spektren sowie der Messdaten.
Automatische Skalenspreizung
Die automatische Spreizung der Ordinaten-Skala gehört ebenfalls zu den nützlichen Eigenschaften des Gerätes, um die Spektren-Ausgabe zu optimieren. Ein aufgenommenes Spektrum wird im Speicher des IR Report 100 abgelegt. Dann kann das Spektrum erneut ausgeplottet werden, so daß der höchste und niedrigste Transmissionswert bei 95% bzw. 5% der Ordinatenskala liegt. Diese Funktion kann einfach durch Drücken der Taste "AUTO span" initialisiert werden.
Selbst - Test
Beim Einschalten des Gerätes überprüft ein Selbsttest-Programm automatisch die Hardware und gibt, falls irgendein Fehler festgestellt wurde, eine Fehlermeldung auf den eingebauten Thermoplotter/printer aus.
Technische Daten
Wellenzahlbereich 4000 - 600 cm -1
Auflösung besser als 4 cm -1 bei 1000 cm -1
Wellenzahlgenauigkeit +/- 8 cm -1 (4000 - 2000 cm -1 )
+/- 3 cm -1 (2000 - 600 cm -1 )
Wellenzahlwiederholbarkeit innerhalb 4 cm -1 (4000 - 2000 cm -1 )
innerhalb 2 cm -1 (2000 - 600 cm -1 )
Ordinatengenauigkeit +/- 0.5%T
Ordinatenwiederholbarkeit innerhalb +/- 0.4%T
100 % -Linie innerhalb +/- 2.0%T (ausg. Absorptionsbereich von H 2 O und CO 2 )
Streulicht weniger als 0.5%T über den gesamten Wellenzahlbereich
Optik
Monochromator f/5 - Filter/Gitter - Monochromator
Gitter 200 Linien /mm (4000 - 2000 cm -1 )
100 Linien /mm (2000 - 600 cm -1 )
Scan-Zeit 4 und 8 Minuten
Or-dinatenspreizung automatisch im Bereich 5 - 95%T
Ordinaten-Modus %T, Abs (0 - 2 A), Einstrahl
Spalt fest
Lichtquelle beheitztes Ni-Chrom-Element, 46 W
Detektor hochempfindlicher Vakuum-Thermo-Koppler
Probenraum 150 (B) x 280 (T) x 130 (H) mm
Printer/platter Thermoprinter/plotter für 180 mm breites Papier
Geräteabmessungen 635 (B) x 590 (T) x 405 (H) mm