Jasco HPLC
Objektnummer | B00016980 |
---|---|
Seriennummer | 016980 |
Nome oggetto | Jasco HPLC |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
model : HPLC
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
The devices are modular designed. Please find the modules you are looking for.
Model PU-980 HPLC Pump
Microprocessor-controlled HPLC Pump with the most advanced proven pumping mechanism
Model PU-980 intelligent HPLC pump covers a wide flow rate range from 1 µl/min with a flow rate precision as good as ± 0.1 %. Versatile programming capabilities allow sophisticated time-based programs of high binary and low pressure ternary gradient elution, flow rate, solvent selection, etc., meeting numerous requirements on HPLC applications in various fields. Model PU-980i Inert HPLC pump assures biological separation without contact with any metallic material.
Features
- Compact, space saving design as small as 150 mm with / 150 mm height
- Built-in program allows high-pressure gradient operation of 2 PU-980 pumps or low-pressure gradient operation of one PU-980 pump and proportioning valve without any external system controller
- Automatic plunger cleaning function provided as standard
Main specifications PU-980 HPLC Pump
Flow rate range: 1 µl/min to 10.0 ml/min with 1 µl/min step
Flow rate accuracy: ± 2% of setting or ±10 µl/min, whichever is greater
Maximum pressure: 500 kgf/cm 2
Time program: 64 steps, up to 10 files
Dimension: 150 (W) x 464 (D) x 150 (H) mm
Weight: Approx. 10 kg
Model UV-970/Model UV-975
Model UV-970 / Model UV-975 intelligent UV/VIS detector covers a wide wavelength range from 190 to 700 nm with D 2 and tungsten lamps (Model UV-970) and from 190 to 600 nm with D 2 lamp (Model UV-975). Both models offers extremely stable baseline with low noise; 2 x 10 -4 ABU/hour, and ±0.5 x 10 -5 AU at 250 nm. Versatile time-programming capabilities are provided for wavelength, response, range, spectral scan, etc. A rapid scan feature allows on-flow spectral acquisition without interrupting chromatographic elution.
Features
- Compact, space saving design as small as 150 mm width/150 mm height
- High sensitivity measurement with the range of 0.0005 ABU
- Wide wavelength range of 190 nm to 700 nm for UV-970 (600nm for UV-975)
- High speed spectral scanning
- Time programming with 64 steps for easy and Optimum chromatographic runs
Specifications UV-975 UV/VIS detector
Optical System
Monochromator: Non-aberration Monk-Gillieson mounting
Diffraction grating: 1200 lines/mm
Spectral bandwidth: 8 nm
Wavelength accuracy: ± 2 nm
Wavelength
reproducibility: ± 0.1 nm
Light source: D2 lamp
Wavelength range: 190 - 600 nm
Photometric System
Type: Dual beam photometer
Noise level: ± 0.5 x 10 -5 AU (at 250 nm with standard response and empty cell)
0.64, 1.28, 2.56 AU/10mV S( short)
Response: Fast (0.05 sec), standard (1 sec), slow (3 sec)
Flow Cell
Type: Front loading cassette cell
Standard flow cell: Taper cell (10 mm path length)
Optional: Preparative cell, high pressure cell, semi-micro LC cell, PTFE cell,
etc.
Input/Output Communications
Analog output: One circuit for recorder output of 10 mV/FS, one circuit for
Integrator output (three settings)
Peripheral Connections: LC-Net, marker IN/OUT, autozero, leak output, program start,
RS232C (optional)
Program Functions
Time program: Time program for wavelength, response, autozero, sensitivity, and
spectrum measurement (in increments of 0.1 min up to 999.9 min,
maximum 64 steps)
Absorption spectrum
measurement range: 200 - 600 nm
Spectrum memory
function : Stores the recorded spectral scans and subtracts the basline.
Ten memories available.
Auto-lamp OFF: Set in 0.1 hour increments from 0.1 to 99.9 hours
Miscellaneous
Dimensions, mass: 150W x 464 D x 150 H mm, approx. 9 kg
Power requirements: 80 W maximum
Model RI-930 Detektor
Model RI-930 intelligent RI detector offers extremely low baseline noise and very stable baseline of 0.5 x 10 -8 RIU and less than 8 x 10 -7 RIU/hour under the conditions with flow cell filled with water and flow of THF with temperature change less than 1°C, respectively. The change of sensitivity range and the purging of reference cell can be done automatically by utilizing time-programming. In addition, temperature of heat exchanger is controllable in the range from 10°C above an ambient to 45°C.
Model AS-950 Autosampler
Model AS-950 intelligent autosampler allows injections up to 50 samples (standard) with high-reproducibility; better than 0.5 % R.S.D and 0.3 % R.S.D on partial loop and full loop injections, respectively. More features such as pre-column derivatization, sample dilution, sample cooling/heating (option) are also available. A wide variety of sample racks makes it possible to use almost all types of sample vials and tubes on the market. Model AS-950i lnert Autosampler of which materials in contact with solvent are polymer and glass is also available.
Specifications AS-950 Autosampler
Sample injection method: Fixed or variable injection (selection made by keypress)
Number of samples: 50 (2.0m1, 0.3m1 vials)
84 (0.5ml vials)
96 (microplate)
Sample rack: Holds 50 vials
Optional: Chromacol Mini Reck (03-CVG, holds 84)
Optional : Microplate Rack
Standard sample loop: 100 µl
Injection volume: Variable injection: 1 - 200 µI (up to 1000 µl with options)
Fixed injection: 5, 10, 20, 50, 100, 200, 500, 1000, 2000µ1
Repeatability: 0.5% (Variable injection, 10 µI)
0.3% (Fixed injection, 20 µl)
Contamination: 0.05% (for 20 gl injection volume)
Sample loss volume: 20 µI (up to 100 µl)
Sample cooling/heating: Electronic cooling/heating unit (optional)
+4°C or 37°C can be selected using a switch
Maximum pressure used: 350 kgf/cm 2
Materials used for
tubing connections: SUS 316, resin, hardened glass
Display: 16 character, 2 line LCD multi-display; settings
entered using numeric keys
Program-Controlled
functions: Program functions (64 steps) and 10 fites. Can randomly set range of sample numbers for injection, injection volume (when using variable injection) and number of injections. Can also execute temporary stop, high priority (urgent) sample processing and add, insert and delete steps.
Self-diagnostics: Checks memory (ROM ,RAM ), DC power, X,Y movement of syringe, Z movement of needle and valve rotation.
External control: Can be controlled by 802-SC or externally controlled through
RS-232C (optional).
Input/Output terminals: INJ. MARKER 3 circuits
STOP OUT 1 circuits
STOP IN 1 circuit
REMOTE INJ 1 circuit
Dimensions: 150 (W) x 300 (W) x 470 (D)
Mass: 12 kg
Power consumption: 50 W
Model HG 980-30 / Model HG 980-31 Mischkammer
These are high pressure gradient mixer modules up to 3 solvents. Model HG-980-30 is for general use in high-pressure-mixing gradient systems with conventional columns. Model HG-980-31 has higher mixing efficiency to offer stable baseline when a mobile phase with UV absorption and detection wavelength needs to be set bellow 230 nm.