Immucor ABS Precis
Objektnummer | B00010746 |
---|---|
Seriennummer | 010746 |
Nome oggetto | Immucor ABS Precis |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
1 |
Tubing guide |
2 |
LabHand mechanism |
3 |
Top cover |
4 |
Front blind |
5 |
Plate washer, valve and pump unit |
6 |
Safety shield |
7 |
Power indicator lamp |
8 |
Plate stacker |
9 |
Incubator tower |
10 |
Tubing block |
11 |
Plate washer |
12 |
Syringe pump |
13 |
Wash station |
14 |
Rack location pins |
15 |
Work table |
16 |
Pipetting position |
17 |
Plate shaker |
18 |
Plate reader |
19 |
SamTrak |
20 |
DT drop position |
21 |
CCD camera (for sample tubes) |
22 |
LabHand |
23 |
Peristaltic pump |
24 |
Sampling Probes |
25 |
Probe ciamp |
26 |
Robotic arm |
27 |
Z-rack |
28 |
Tubing ciamp |
29 |
Tubing sleeve |
30 |
Syringe pump outlet tubing |
1 |
SamTrak rack (samples) |
2 |
Pipetting position an shaker |
3 |
Pipetting position |
4 |
Rack for reagents |
5 |
Wash station |
6 |
Rack for troughs |
7 |
Plate washer |
Flexible Testkonfigurationen
Das offene System des ABS Precis bietet dem Anwender die gewünschte Flexibilität bei der Testkonfiguration.
Das Pipettierschema ist u.a. bei Blutgruppenbestimmungen, Antigen Typisierungen und serologischen Verträglichkeitsproben nach den spezifischen Laboranforderungen frei wählbar.
Ein breites Testspektrum...
· ABD Kurzbestimmung
· ABD Bestimmung mit Serumgegenprobe
· weak D Bestimmung
· Rh-Untergruppen und Kell-Typisierung
· Bestimmung seltener Antigene
· Antikörpersuche, Capture-R Ready‑Screen® (I und II), (4), )Pooled Cells)
· Antikörperdifferenzierung mit Capture-R Ready-ID ®
· serologischeVerträglichkeitsprobe
· Eigenkontrolle
· Pipettierung geringerer Volumina (Neugeborenenblutgruppe)
· thrombozytäre Antikörpersuche Identifizierung undVerträglichkeitsprobe mit Capture-P ®
· Qualitätskontrolle der Reagenzien
...kombiniert mit hoher Kapazität
· bis zu 192 Proben
· bis zu 30 Mikrotiterplatten
· variable Anzahl von Reagenzienracks mit je 12 Positionen
· entnahmesimultan gerührte Reagenzienpositionen
· Inkubator mit 4 temperierbarenPositionen für Mikrotiterplatten
Schnelligkeit
Die Geräteausstattung mit 4 Pipettiernadeln, drehbarem Pipettierteller, 4 temperierbaren Inkubatoren und die externe gleichzeitige Zentrifugation mehrerer Platten tragen maßgeblich zum besonders hohen Testdurchsatz des ABS Precis bei.
General Specifications
Item |
Description |
Accessories & Options |
Microplate Identification System by barcode reading. Additional Plate Stacker and Incubator Tower modules are available for some configurations. Tube racks and SAMTRAK racks for tube diameter 11-18 mm. Standard and customized Reagent racks. Reagent stirrers. Microplate shaker capacity 1, 2 or 4 microplates. Tube Rack shaker (192 tubes). |
Barcodes |
Most commercially available barcodes can be read by the SAMTRAK CCD barcode reader (sample tubes) and the Plate Identification System CCD barcode reader. |
Capacity Standard Configuration |
Up to 192 tubes and 20 plates. |
Carry Over |
Washable tip: down to 10 -7 with sufficient tip wash. Disposable tip: Zero |
Incubator Tower |
Capacity 6 microplates, or 4 temperature controlled plates + 4 at ambient room temperature. Temperature controllable from 5° C above ambient temperature, in steps of 0.1° C, accuracy 0.2° C. |
Interface |
RS232 C/CCIT V.24 Asynchronous serial ASCII. |
Liquid Detector |
Capacitate with clot detector. Minimum detectable volume 200 µl (with 0.9% sodium chloride in a tube diameter 16 mm). |
Operating Conditions |
Temperature: 15° C to 30° C/60° F to 85° F. Relative Humidity: 10-85% at 30° C/85° F or below. |
Pipetting Throughput |
Approximately 6 minutes to fill a plate with 100 µI sample per well, tip wash 2 mI or disposable tips. |
Precision and Accuracy |
Pipetting better than 1% at 10% syringe volume based on volume range 10 µl to 1 ml, gravimetric evaluation. |
Printer |
Most commercially available models. |
Power |
Self-regulating power, and operate at 90 to 130 volts AC and 180 to 260 volts AC, with a line frequency of 47-63 Hertz. |
Pumps |
4 x high precision Syringe Pumps for precision liquid handling size variable from 250 µl to 5 ml.. |
Reader |
As an integral part of the Plato 3 Series Robotic Microplate Processors, the QIAGEN Instruments plate reader is programmed and controlled by the PC resident software. Plates are automatically taken to the reader according to the demands of the preprogrammed assay. As the plate leaves and re-enters the storage stack or incubator tower, its identity can be read with the optional plate identifier barcode reader. This helps to eliminate sample-tracking errors. |
Item |
Description |
SAMTRAK |
Positive Sample Identification unit is installed directly on the work surface to minimize bench space. CCD camera is used for bar code reading. Linear racks hold the sample tubes. Each linear rack holds 16* 12 mm tubes, 12* 12 mm tubes, or 12* 16 mm tubes. Standard configuration SAMTRAK holds a total of 12 racks. |
Tube Size |
Maximum: Tubes OD 18 mm Minimum: Tubes OD 8mm |
Robotic Transfer Speed |
Approximately 4 seconds to take a plate from the stack and place it on the work surface, washer or reader. |
Tip Design |
Washable: Low iron stainless steel (AMPHIC) coating on the inside, and with a ceramic coating on the outside. Other materials may be available. Disposable: Conductive, volume 250 µI or 1 ml. |
VARISPAN® |
From 9-40 mm. |
Volumes |
Minimum sample/reagent volume 5 µI. Maximum sample/reagent volume 1 ml. |
Washer |
As an integral part of the Plato 3 3000 Series Robotic Microplate Processors, the QIAGEN Instruments plate washer is programmed and controlled by the PC resident software. Plates are automatically taken to the washer according to the demands of the preprogrammed assay. 8- or 16-way wash head. Up to 3 different wash Iiquids can be used in addition to rinse liquid. Fully programmable from Plato 3 software. |
Weights & Dimensions
Model Number |
3000 |
3101 |
3301 |
NET. WT, KG |
38 |
50 |
80 |
NET WT. LBS |
84 |
110 |
180 |
Overall Dimensions mm: Width Depth Height |
900 710 600 |
1180 710 600 |
1180 710 670 |
Overall Dimensions ins: Width Depth Height |
36 28 24 |
46.5 28 24 |
46.5 28 26.5 |
Reader Specifications
|
Description |
||
Photometric Method: |
Single/dualmultiple wavelength measurement. 8-measurements, continuous scanning photo‑optical method. Dynamic Digital Control of Light Intensity (DyDiCoLi). |
||
Wavelength Range: Standard 400-750 nm. |
Optical density: 0.00-2.5 0.00-2.0 |
Indication range: 0.000-3.000 |
Measurement range: 400-750 nm 340-400 nm |
Accuracy: |
<1% at 405 nm, 1.0 OD |
||
Linearity: at 405 nm |
0.1 to 0.2 OD +/-1% 0.2 to 1.0 OD +/- 0.5% 1.0 to 2.0 OD +/-0.75% 2.0 to 2.5 OD +/-1% |
||
Linearity: at 340 nm |
0.5 to 1.0 OD +/- 2.5% 1.0 to 2.0 OD +/- 2.5% |
||
Reproducibility: |
Better than +/- 0.3% at 405 nm, 1.0 OD. (SCHOTT neutral density) |
||
Filter type: |
Dielectric Interference. Filter wheel with up to 6-filters |
||
Light Source: |
Controlled Tungsten Halogen Iamps. |
||
Photo Detector: |
Silicon photo diodes |
||
Standard Filters: |
405, 450, 550, 492, 620, 690 nm |
||
10 nm +/- 2 bandwidth All filters must be specified at the time of ordering. |
Washable Tips |
Description |
Disposable Tips |
3101 SI |
Robotic liquid handling with robotic plate management, integrated microplate washer, SAMTRAK positive sample identification System, and temperature controlled tower for incubation of up to 6 microplates. |
3101 DSI |