IKA C 200
Objektnummer | B00017316 |
---|---|
Seriennummer | 017316 |
Nome oggetto | IKA C 200 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : IKA
model : C 200
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
C 200 Calorimetersystem
C 200-System consists of the following components:
Measuring cell C 200
Decomposition vessel C 5010
Oxygen filling Station C 248
Consumables for calibrations and Installation
Space-saving and low tost combustion calorimeter for determing gross calorific values of liquid and solid Samples.
Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
Suitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories wich less analyses ..
Manual handling for water and oxygen filling.
Four different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating talks.
Clear and easily explained display which is simply to use .
With an external power pack, "world tension useable" from 100 - 240 V AC, 50/60 Hz.
The operating voltage of the calorimeter is 24
Friendly in aftersales
Manual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minnte.
All calculations have to be done manually.
At the other three modes ignition and calculation of the gross calorific value will be done automatically.
The gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually.
The modes have different measuring times:
Isoperibolic: approx: 17 min.
Dynamit : approx. 8 min
Manual : approx. 17 min
( depend on the operator)
Time controlled : 14 min
Technical Data
Measuring range max. [J] 40000
Measuring mode dynamic 25°C yes
Measuring mode isoperibol 25°C yes
Measuring time dynamic approx. [min] 8
Measuring time isoperibol approx. [min] 17
Reproducibility dynamic (1g benzoic acid NBS39i) [%RSD] 0.1
Reproducibility isoperibol (1g benzoic acid NBS39i ) [%RSD] 0.1
Working temperature max. [°C] 25
Temperature measurement resolution [K] 0.0001
Interface printer Centronix
Interface PC RS232
Oxygen filling no
Degasification no
Decomposition detection no
Decomposition vessel C 5010 yes
Dimensions (W x H x D) [mm] 400 x 400 x 400
Weight [kg] 21
Permissible ambient temperature [°C] 20-25
Permissible relative moisture [%] 80
Protection class according to DIN EN 60529
IP 20
RS 232 iterface
yes
Vollage [V] 100 - 240
Frequency [Hz] 50/60
Power Input [W] 120
The decomposition vessel can be equiped in to use an combustible crucibles C 14 (accessory C 5010.4 attachment is neessary)
User-friendly Software C 5040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible
Up to eight IKA measuring cells can be controlled by a single PC, using a multiserial plag in card PCI 8.2 (accessory)
Accessories: C 6 Quartz crucible, big, C 14 combustible crucible, C 10 Acetobutyrate capsules, C 29 Pressure gauge, Oxygen, C 43 Benzoic acid NBS 39i, C 710.4 Cotton thread, cut to length, C 21 Pelleting press, C 4 Quartz dich, C 5 Set of VA Combustion crucibles, C 12 Combustion bags 40 x 35 mm, C 12 A Combustion bags 70 x 35 mm, C 5010.4 Attachment for combustible crucible C14, C 5010.5 crucible holder, big, C 15 Paraffin strips, C 723 Benzoic acid, blister package, C 200.1 Measuring Cup 2000 ml, C 723 Benzoic acid BIG Package, C 16 Parafilm, C 17 Paraffin, C 5010 Decomposition vessel, Standard, C 5010.3 Ignition wire, spare, C 5030 Venting Station, C 9 Gelatine capsules