Soldé

ICT Beam boost

Seriennummer: 010236
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
ICT reattore fotochimico dell'aumento fascio luminoso. Anno: 2003 Prezzo originale: 2.300, - Euro.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00010236
Seriennummer 010236
Nome oggetto ICT Beam boost
Stato Archived Product

Gruppo prodotti: HPLC-Miscellaneous

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              ICT

Modell:            Beam boost

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

NEW BEAM BOOST™ Photochemical Reactor

  • Increased sensitivity/selectivity
  • Easy-to-use and absolutely reproducible
  • No band broadening
  • Nano to picogram detection enhancement
  • No sample dilution
  • Applicable to precolumn derivatization
  • Use in conjunction with UV, fluorescent, photo diode and electrochemical detectors
  • Three external event interfaces, computer compatible

Photochemistry in HPLC offers new opportunities in levels of detection and selectivity without the disadvantages of pre or post column derivatization. This is done by simply exposing the analyte in the effluent from any HPLC column to ultra violet light. This is done in a transparent Teflon tube, crocheted to decrease the influence of band broadening. A wide variety of chemical reactions can be forecasted leading to new fluorescent molecules, molecules that can now be electrochemically detected or detected by fluorescence or simple UV enhancement. This is all done quantitatively in a very short period of time. Chemoluminescence has also been reported with this system. This brand new Beam Boost system has a host of new features developed from 8 years of experience with thousands of samples as background. These features include switchable 115/230 volts with more stable electronics so that the results are not affected by power fluctuations. An LED indicates power on as well as lamp fail and leak detection. Lamp life has been extended to well over 500 hours. State of the art electronics include computer links for on/off control and pump shut down if a leak is detected.

In the field of chiral chromatography this instrument has been invaluable in increasing the detection limits of many chiral drugs and their metabolites and perhaps more importantly, allowing for a change in detection parameters that improve detectability and quantitation. In the example below, 50% enhancement is seen in the UV. With a fluorometer the enhancement would have been 30 fold. A large number of examples also exist for the use of ECD detectors where increases of 10 to 100 times have been obtained.

Part of labexchange logo