Archivio

Hunter Color Quest XE

Seriennummer: 012492
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00012492
Seriennummer 012492
Nome oggetto Hunter Color Quest XE
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Hunter

Modell:            Color Quest XE

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

ColorQuest® XE Spectrophotometer

The ColorQuest XE is a high performance spectrophotometer that can be used in production and in the laboratory for inspecting raw materials, evaluating finished product or developing methods for color analysis. You can measure opaque, transparent and translucent solids and liquids for properties such as reflected color, opacity, brightness, strength, transmitted color, APHA and haze. lt is ideal for use in a variety of industries including textile, plastic, chemical, coating, food, building materials and paper.

With ColorQuest XE's inter-instrument agreement, you can be confident that differences between measurements are due to product color changes, not instrument variability. Materials on the borderline of accepted tolerances will not be unnecessarily rejected and you will confidently ship more product. ColorQuest XE is ideal for use in quality control and color formulation applications.

Obtain accurate, precise measurements.

The ColorQuest XE uses d/8°(sphere) geometry, which conforms to ASTM, ISO, CIE, DIN and JIS standards for reflection measurements. The large integrating sphere is coated with Spectraflect TM which has superior optical characteristics and greater durability than traditional BaSO 4 coating. Transmission measurements are male using de geometry. A single xenon lamp is flashed "softly" to avoid triplet absorption yet provides sufficient energy to give excellent measurement precision, even on Bark and highly saturated samples. The short duration flash will not heat your sample and has minimal photochromic effect. Having extended life, the xenon lamp will last at least eight years in typical use and is easily replaced by the user.

The reflectance standard supplied with ColorQuest XE has been calibrated using reference standards traceable to the National Physical Laboratory (NPL), and using methods outlined by the National Institute of Standards and Technology (NIST).

To ensure measurement repeatability and stability, ColorQuest XE uses true double-beam optics that monitor light reflected from the sphere and spectrally compensates for any variation. To ensure colormetric measurement accuracy and inter-instrument agreement, each system is tested with calibrated color tiles traceable to the NPL.

Easily measure samples of all types and sizes.

The geometry of the ColorQuest XE allows you to perform color measurement of transparent, translucent and opaque samples. Solid samples are easily positioned and supported at the reflectance port with the ergonomically designed sample clamp. For measurement of powders, granules and opaque liquids the Reflectance Sample Shelf accessory would be used to position a sample cell.

The large transmission compartment is open an three sides to make sample measurement easy. The compartment can accommodate samples ranging from thin films and glass to 80mm transmission cells. Diffuse transmittance, regular (direct) transmittance, and haze can be measured.

Other measurement functions include:

• Automated gloss control - Specular Included/ Excluded reflectance measurements, to compare glossy and non-glossy surfaces, are made quickly and automatically. The Specular port cover position is controlled by the system computer, which also stores standardization modes for quick and automatic recall when multiple mode measurements are made.

• Large area and optional small area

remove the 25.4-mm LAV aperture and insert the 6.3mm SAV aperture. When switching modes, the ColorQuest XE automatically changes its lens system and confirms that the proper port aperture is in place. An optional sample viewing screen assures the position of samples at the reflectance port.

• Accurate fluorescent measurement - The UV Control option permits accurate measurement of fluorescent and optically brightened samples. UV content of light striking a sample is automatically adjusted. This provides accuracy, stability and reading agreement between multiple instruments for whiteness and brightness measurements.

Controlling the UV energy is superior to "numerical calculation" systems that assume fluorescent linearity. The Fluorescent Standard available from HunterLab is traceable to the Hohensteiner Institute.

Get high reliability with minimum maintenance

The ColorQuest XE is engineered to be reliable in industrial environments. The Spectraflect coated sphere doesn't yellow like conventional BaSO 4 and will remain highly reflective for years. The single source lamp has extended life - more than one million flashes and can be replace by the user in minutes. The ColorQuest XE uses many components designed for an-line instruments and inherits the same ruggedness and reliability.

ColorQuest XE diffuse/8° Optical Sensor includes the following features:

Ø       Spectrophotometer for Reflectance/ Transmittance Color Measurements : Provides visible wavelength data from 400-nm to 700-nm, uses a long-life xenon lamp to provide illumination closely matching D65.

Ø       Dual-beam Optics: Provides the greatest level of accuracy, repeatability, and long-term performance.

Ø       Dual-channel polychromator for sample and monitor information. Holographic grating with 40 element detection array provides spectral data at 10nm intervals.

Ø       Sample Measurement:

Reflectance : Large Area of View (LAV) of % inch (19-mm) centered within 1 inch (25-mm) port with removable reflectance port plate and computer sensing. Small Area of View (SAV) of 3/8 inch (9.5-mm) centered with 1/ inch (6-mm) port with removable reflectance port plate and and sample viewing screen for precise sample placement.

Spring-loaded sample clamp with 8 inch throat depth for long samples and quick positioning. One-button, quick release for reflectance port access or sample clamp removal.

Transmittance at TTRANport: 17.4-mm sample viewing centered within 1 inch (25-mm) port in LAV, 10-mm sample viewing centered within 1 inch (25-mm) port in SAV. Transmittance compartment can accommodate samples and cell pathlengths to 4 Inches (80mm).

Ø       Automated UV Control: Automatic adjustment of light source UV content for the accurate measurement of optical brightners and UV induced fluorescence. Includes calibrated fluorescent standard and motorized UV Filters (420nm, 460nm).

Ø       Read/Macro Button: Ergonomically positioned "read" button located at front of sensor allows local measurement activation as well as activation of pre-programmed macro sequence of steps via Universal Software.

Specifications

Measurement Principal:          Dual-beam spectrophotometer

Geometry:                               Diffuse/8°

Spectrometer:                                     256 element diode array and high resolution, concave holog-raphie grating

Sphere Diameter:                    15.2cm (6")

Sphere Coating:                      Spectraflect

Viewing Apertures

   Large Area View:                  25.4mm (1") illuminated, 19.Omm (3/4") measured

   Small Area View Option:      9.5mm (3/8") illuminated, 6.3mm (1/4") measured

Lens Switching for

LAV/SAV Option:                     Automatic

Specular Component:             Automated Included/Excluded

Spectral Range:                      400nm - 700nm

Wavelength Resolution:          <3nm

Wavelength Accuracy:            0.1 nm

Effective Bandwidth:               10nm equivalent triangular

Reporting Interval:                   10nm

Photometrie Range:                0 to 200%

Photometrie Resolution:         0.003% (0.01% reported)

Light Source:                           Pulsed Xenon lamp, filtered to approximate D65

Number of Flashes per

Measurement:                         1 in LAV mode (4 in SAV mode)

Lamp Life:                               > 1,000,000 flashes, user replaceable

Measurement time:                 < 1 second

Minimum Interval Between

Measurements:                       3 seconds

Transmission Modes:             Regular (direct) and Total

Transmission

Compartment:                         Open an 3 sides

                                               10.2cm D X 35.6cm Ulf x 16.5cm H (4"D x 14"W x 6.5"H)

Automatic UV Control Option:420nm and 460nm cutoff filters, with automatic UV calibration Standards Conformance

Reflectance:                            CIE No.15, ISO7724/1, ASTM E 1164, DIN5033 Teil7 and JIS Z 8722 Condition C

Transmittance:                        CIE No.15, ASTM E 1164 and DIN5033 Teil?

Colorimetric Repeatability:      ≤ 0.03 ∆E* CIELab on white tile in LAV and SAV modes

(20 readings)                           ≤ 0.05 ∆E* CIELab on blue denim tile LAV and SAV modes

Spectral Repeatability:            Standard deviation within 0.1% in LAV and SAV modes

Inter-instrument Agreement:   ∆E*≤ 0.15 CIELab (Avg) on BCRA II Tile Set

                                               ∆E*≤ 0.25 CIELab (Max) on BCRA II Tile Set

Traceability:                             Instrument standard calibration traceable to the National Physical Laboratory (NPL) value

Dimensions:                           

Height:                                    27.9cm (11.0")

Width:                                      42.0cm (16.5")

Depth:                                      49.8cm (19.6")

Weight:                                   20.4kg (45lb)

Power:                                     100 to 240 VAC, 47 to 63 Hz

                                               60 watts passive, 120 watts continuous use

Interface:                                 RS-232C, 9,600 baud D9 (female) terminal

Operating Environment:          10 to 40° C (50 to 104° F), 10 to 90% RH, noncondensing

Storage Environment:             -21 to 66° C (-5 to 150° F), 10 to 90% RH, noncondensing

Standard Accessories:

White calibration tile, Black calibration Iight trap, Green check tile, Didymium check filter, Transmittance zero calibration plate, Reflectance sample clamp, LAV aperture, RS-232C cable, Power cord, Certificate of NPL traceability

Optional Accessories:

Small area view, Retroviewer for SAV, UV Control/Exclusion, Fluorescent standard,

Blue denim tile, Reflectance sample shelf, Transmission clamp, Transmission cell holder, Transmission cells (50mm, 33mm, 20mm,10mm), Flow through cell holder, Flow through cells (50mm, 20mm,10mm), Compression clamp, Glass sample cup, 25mm port plate with glass, Foot switch, Skein holder, and other special sample handling devices, Universal Software® (no charge with sensor order), EasyMatch® software, Computer.

ColorQuest XE Touch

This option includes a large, adjustable, back-lit display that can be read in any lighting environment. This Multi-Function Display uses touch screen technology for simplicity of operation.

The ColorQuest XE-Touch is high perfromance, self­contained, reflectance/transmittance spectrophotometer. It measures the color of plastic, paint, textile, paper, chemical, pharmaceutical, petroleum and other products. In addition to color, metrics such as APHA (Hazen), Saybolt, Gardner Scale, ASTM D1500, Yellowness Index, Whiteness Index and Transmission Haze can be quantitated. ColorQuest XE-Touch has a large,adjustable, back-lit display that can be read in any lighting environment This display uses touch screen technology for simplicity of operation. Prompts appearing on the display are touched with a finger to initate the action. Sample ID or data entry is made simple by use of an alphanumeric keypad displayed on the touch screen. Data can he output directly to a printer. To enhance functionality, a novel macro-scripting-language feature will allow the user to create custom applications that can be downloaded to the instrument. Commands such as prompts, measurement, mathematical equations, etc.can all be user customized. The system can also be used with a PC and HunterLab’s Universal color quality control software.

Gruppo prodotti: Colorimetri

Non è stato trovato alcun prodotto corrispondente alla selezione.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure