Soldé

HTA HT800L

Seriennummer: 018486
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00018486
Seriennummer 018486
Nome oggetto HTA HT800L
Stato Archived Product

Gruppo prodotti: HPLC-Autocampionatori

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       HTA

model :                   HT800L

annotation :           Dokumente engl .

 

 

 

HT800L

The HPLC sampler

 

HT800L is a compact and versatile autosampler for highly precise injections into HPLC and UHPLC

 

 

 

Key Features:

  • Large autonomy: up to 120 vial per run or 2 SBS plates
  • Management of full loop, partial loop and microliter pick-up injections with unattended results
  • Dilution, derivatization , phIspiking and internal standard addition capability within standard version
  • Up to 10+1 reagents available
  • Service friendly design

 

Fit most common HPLC, UHPLC and LC/MS systems . The repeatability, the versatility, the high sample throughput and the economic pricing makes this autosampier a good choice for a large variety of HPLC applications

 

Easy-to-use. User-friendly PC Interface to create methods and sequences in a simple way. Additional keypad designed for every operation that will be uncomfortable to do by a Data System; for wake-up and shut down maintenance, extra washing and line rising.

 

HT800L provides excellent analysis efficiency through its accurate syringe system that takes care to assure high performance with every vial/plate configuration unlike pressure based system.

 

Designed for minimal carry-over . Double step washing (by system liquid and by an aggressive solvent), internal and external needle washing and total line washing ensure a minimal carry-over.

 

It can handle up to 120 vials per run and it can work with different type of SBS plates. Removable rack assures easy and quick sample loading; polarization on racks assures error free procedure.

 

Fast . HT800L can work at very high speeds (low cycle time).

Safe . A sampling chamber sensor ensures that when the door is open a deboosting protection is activated, while lights inside sampling chamber assure an easy visual contact with samples.

 

Dilution, derivatization , pH spiking and internal standard addition are available within the standard version: no extra cost required. These operations can be performed in place or in an empty vial by sample dispatching ( Quantif ed Preparative).

 

Versatility . Up to 10+1 different reagents are available to assure complex task and long autonomy.

 

Different injection modality . Full loop is performed with very high accuracy values, while partial loop and microliter pick up also allow sample saving. The variable f ll speed and the viscosity delay allow a wide range of sample viscosities; programmable sampling depth assure high sample recover capacity.

 

 

 

Biocompatible Version

For handling more complex sample and assure a wider pH range covering.

 

Cooling Version

Cooling and heating capability to maintain samples and reagent at a controlled temperature.

 

UHPLC Version

For micro volume as low as 1ml, for pressure as high as 15,000psi.

 

 

 

HT800L specifcations

 

General specifications

Syringe volume:         500µl (Standard); Optional: 250µl and others

Loop :                            100µl (Standard); Optional: 20µl and others

Tray capacity:             120x2ml vial; micro-inserts supported

Optional:

- 2x96-SBS-plate (micro, shallow, deep)

- 2x96-PCR-plate (not-skirted, semi-skirted, skirted)

- 2x96 microtubes rack

Cycle time:                  50sec.

Valve:                           6-port, 2-position

 

Analytical performance

RSD (vol. >5µl):         Full loop: <0.3% ( tipically 0.15%)

Partial loop: <0.5% ( tipically 0.25%)

Carry over:                   0 (Not detectable)*

(*)Tested with Uracile 50ppm in mobile phase 75% methanol : 25% water; Column C18; 2 purge cycles; detector: UV ~ xed length

Linearity:                      0.999

 

Wash (Pre & Post Injection)

Washing cycle:          up to 9 (Mode: every injection/sample/step) Reagents:       

up to 2 different reagents for wash function

 

Filling

Sample volume:         step of 1µl

Filling speed:               programmable up to 2500µl/sec

Viscosity delay:          0-25s

 

Injection

injection speed:          1-2500µl/sec

Injection mode:           full loop, partial loop, microliter pick up

Air gap:                        programmable

Flush volume:             step of 1µl

Analysis time:             0-999min

 

Diluition , derivatization ,pH spiking, IS addiction

Sample dispatch:        step of 1µl

Reagent addiction:      step of 1µl; up to 3 different reagents

Mixing cycle:                programmable

Intermediate

wash cycle:                 up to 9 (with reagent or sample)

Reaction time:                         0-100 minutes (0.1 minutes step)

 

Phisical characteristics

Dimensions

( WxHxD ):                     300x346x546mm

Weight:                        ca. 19Kg

Power:                                     115V/230V; 50Hz/60Hz

Connection:                 RS232 (Standard); Optional: USB

 

UHPLC version

Syringe volume:          100µl (Injection mode: full loop,

partial loop)

Loop :                            5µl

RSD (vol. ≤5µl):           Full loop: <0.4%; Partial loop: <1%

 

Cooling

Temperature range

conditioning :                from 4°C to 60°C

Temperature

accuracy

( between the vials):     +/-1°C ( tipically +/-0,5°C)

Cooling capacity:         about 15°C below the RT (on the vial)

Working ambient

temperature :               25°C +/-10°C

Weight:                        ca. 5Kg

 

 

Require a PC for method and sequence editing.

 

Part of labexchange logo
Search engine powered by ElasticSuite