Gascromatografi

HP 5890 II GC with Dual TCDs, Dual EPC controlled

Preis auf Anfrage
Seriennummer: 12302
Stato: Labprocure?
Spedizione: 4-6 weeks
Descrizione:
Specifiche Dispositivi riscaldati. Cinque zone riscaldate standard: due rilevatori, due ingressi, una zona aggiuntiva. Metodi memorizzati: due. Capillare split/splitless. Intervallo fino a 400°C con incrementi di 1°C. Il design a contropressione consente di regolare la portata divisa in modo indipendente senza influenzare la portata della colonna. Spurgo del setto integrato a 3 ml/min. Accetta colonne con diametro esterno fino a 1,2 mm. Il design multimodale include l'iniezione split e splitless. Tempo di tracciamento splitless variabile con incrementi di 0,01 minuti. Rilevatore di conducibilità termica. Gamma fino a 400°C. Il design a filamento singolo (per colonna singola) prevede la commutazione fluidica dei flussi di gas di riferimento e di trasporto dell'analita. Minimo rilevabile: 400 pg/ml di gas di trasporto - equivalente a 1 ppm di neon in 1 ml di aria. Gamma dinamica lineare: +/- 5% nell'intervallo 10^5. L'impostazione del guadagno digitale può essere programmata nel tempo tramite la tastiera. Condizioni: rilevatore. -100°C, flusso di commutazione di 45 ml/min e flusso di analita di 30 ml/min di elio, materiale campione propano. Rivelatore fotometrico di fiamma. Gamma fino a 300°C. Colonne capillari con un diametro interno di 100-530 µm si inseriscono attraverso la linea di trasferimento fino alla base della fiamma. Due modalità di combustione: aria/idrogeno o ossigeno/idrogeno. Visualizzazione del segnale del rilevatore per rilevare quando la fiamma è accesa. Accensione fiamma tramite pulsante. Modalità zolfo: sensibilità fino a 20 pg S/secondo, intervallo 10^3, selettività 10^5 g S/g C. Modalità fosforo: sensibilità fino a 0,9 pg P/secondo, intervallo 10^4, selettività 10^6 g P /g C. Forno a colonna. Intervallo operativo: da 4°C sopra la temperatura ambiente a 450°C. Immettere i setpoint: 1°C per le temperature, 0,1°C per le tariffe del programma. Programmazione: Velocità da 0,1 a 70°C al minuto, tempo di funzionamento massimo 650 minuti, tre rampe con punti di arresto iniziale e finale. Questo GC HP 5890 II ricondizionato con doppio TCD e doppi ingressi su colonna controllati da EPC è in ottime condizioni Labprocure è responsabile di questa unità.
Quotation
Maggiori Informazioni
Objektnummer C00012302
Seriennummer 12302
Nome oggetto HP 5890 II GC with Dual TCDs, Dual EPC controlled
Stato Labprocure
Fabbricante Hewlett Packard
Spedizione 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Gruppo prodotti: GC

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure