Hoffmann La Roche Pentra 120
Objektnummer | B00013714 |
---|---|
Seriennummer | 013714 |
Nome oggetto | Hoffmann La Roche Pentra 120 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
TECHNICAL SPECIFICATIONS
The PENTRA 120 is a medical device used to measure the characteristics of blood tested in laboratories.This device includes both hardware (mechanical and pneumatic) and software program technologies. The PENTRA 120 has the following characteristics:
General configuration
A - Given parameters
* 38 parameters :
- WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW
- PLT, MPV, PCT, PDW
- LYM#, LYM%, MON#, MON%, NEU#, NEU%, EOS#, EOS%, BASO#, BASO%, ALY# (atypic lymphocytes), ALY%, LIC# (Large Immature Cells), LIC%
- RET#, RET%, RETL%, RETM%, RETH%, RETLratio, RETMratio, RETHratio, IMM%, MFI%, MRV, CRC
* 22 parameters (US configuration) :
- WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW
- PLT, MPV
- LYM#, LYM%, MON#, MON%, NEU#, NEU%, EOS#, EOS%, BASO#, BASO%
- RET#, RET%
* High definition of WBC differentiation matrix
* High definition of RET repartition
* RBC and PLT histograms
* Qualitative and quantitative flags
* Pathology flags
B - Throughput analyses
CYCLE |
AUTO |
MANUAL |
RET |
120/h |
60/h |
CBR |
120/h |
60/h |
DIR |
60/h |
60/h |
CBC |
120/h |
60/h |
DIFF |
120/h |
60/h |
C - Automatic mode (closed tubes)
* Vertical cassette loader
* 10 tubes per cassette
* Loader capacity: 15 cassettes
* Continuous loading capability
* Cassette selection, CBC or CBC + DIFF or CBC+RET or DIFF+RET or RET
D - Tube identification
* Closed tube mode:
- With the alphanumerical or front panel keyboard
- With barcode labels: tubes and cassette identifications
* Microsampling mode:
- With the alphanumerical or front panel keyboard
- With barcode labels: tube identification
E - Memory capacity
* 90,000 patient results on hard disk with curves and matrix in 5DIFF analysis mode
* Backup on floppy disk available
F - Statistics and quality control
* Specific menus for statistics and quality control
* XB control
* Daily mean
* Westgard
* LJ graphs
G - Reagents
* 6 reagents, 4 integrated (*)
- ABX DILUENT
- BASOLYSE
- EOSINOFIX (*)
- ABXAL PHALYSE (*)
- ABX CLEANER (*)
- RETIX (*)
H - Display
* LCD black and white backlighted
* Optional color station for result validation (PC type)
I- Data processing
* 68340 type microprocessor
* Multifunction, multitask
* 350 to 500 Mb hard disk capacity
* 3.5" floppy disk drive
* RS232C output
* Mono or bidirectional connection
Software functional requirements
The software program has been developed with a 68340 type microprocessor and microcontrollers for key operation, computation and result output. This software was developed with the functional requirements given below:
A - Power on processing
* Boot and software initialization
* hardware initialization including compressor, printer and motors
B - Initialization processing
* Startup cycle (includes an autocontrol cycle, a diluent rinse, a blank cycle check)
C - Operation with numerical keyboard and menus
* Result analyses
* Result review
* QC
* Calibration
* Maintenance
* Setup
D - Calibration
* Automatic procedure with open or closed tubes
* Direct entering of calibration coefficients
E - Measurements and computation
* Impedance change for WBC, RBC, PLT, BASO, HCT
* Spectrophotometry for HGB
* Impedance change and Iight scattering for LYM%, MON%, NEU%, EOS%, ALY% and LIC%
* Computation from stored data that was directly measured for MCV, MCH, MCHC, RDW, MPV, PCT, PDW, LYM#, MON#, NEU#, EOS#, ALY# and LIC#
* Impedance change, Iight scattering and fluorescence for RET# and RET%
F - Outputs
* Hard copy printing
* External output (RS232C)
G - Error/troubleshooting processing
* Error message display
* Sampling stop in automatic mode
* Fully automatic autocontrol cycle
* Maintenance and troubleshooting procedures
PHYSICAL SPECIFICATIONS
Power requirements
A - Instrument:
- Power supply: 100V, 110V, 220V, 240V, 50/60Hz
- Consumption: 650W (routine)
900W (startup)
B - Laser: 800W in stand-by mode
2KW maxi
Operating temperature and humidity
- 18 - 32°C
- Up to 95% without condensation - Avoid exposure to direct sunlight
- Temperature gradient: 2°C per 3 hours
- Reticulocyte Option temperature range : ~ 8°C
Laser specifications
- Laser Spectra-Physics 163A, Argon type at 488nm
- Class IlIb
- Emission power: 25mW
- Power consumption: 2kW
Dimensions and weight
A - PENTRA 120 5DIFF
- Height: 67 cm
- Width: 117 cm
- Depth: 55 cm
- Weight: 90 kg
B - PENTRA 120 RET
- Height: 75 cm
- Width: 117 cm
- Depth: 55 cm
- Weight: 110 kg
C - Dot matrix printer
- Height: 17 cm
- Width: 46 cm
- Depth: 38 cm
- Weight: 10.5 kg
D - Laser printer
EPSON printer :
- Height: 217 mm
- Width: 352 mm
- Depth: 407 mm
- Weight: 5 kg
E - Laser power supply
- Height: 14 cm
- Width: 16 cm
- Depth: 28.5 cm
- Weight: 11.5 kg
Wastes
- Automatic disposal, level control
- Waste handled according to local/national regulations
Minimum sample volume
- Manual cycle: 130µI
- Automatic cycle: 200µl
Dilution ratlos
- WBC/HGB: 1:234
- RBC/PLT: 1:10 000
- BASO: 1:200
- LMNE: 1:80
- RETIC: 1:3125
Counting aperture diameters
- RBC chamber aperture: 50pm
- LMNE flowcell aperture: 60pm
- BASO chamber aperture: 80pm
- WBC chamber aperture: 100pm
- RET flowcell aperture: 60pm
HGB measurement
- Modified Drabkin method (cyanmethemoglobine) - Light source: Electroluminescent diode
- Wavelength: 550nm
- Bandwidth:10nm
Cycle durations
- STARTUP cycle : 229 to 341 seconds (depending on the blank cycle number)
- SHUTDOWN cycle : 121 to 131 seconds (depending on the compresseur Status : ON or OFF)
SUMMARY OF PERFORMANCE DATA
A total of 20 blood specimens were analyzed in three laboratories. These specifications can be taken into account only for a clean and well-maintained Instrument according to the procedures given in section 8 of this manual.
Within Run Precision
These specimens include normal and abnormal samples. The table below describes the range of %CV's for all samples. They are categorized as normal or abnormal samples based on the PENTRA 120 Normal Range given in section 9.3.7. Precision calculations were not performed for parameters which produced flags or error alarms.
|
NORMAL |
ABNORMAL LOW |
ABNORMAL HIGH |
||||
|
N |
Range of % CV |
N |
Range of % CV |
N |
Range of % CV |
|
WBC |
20 |
1.39 - 1.64 |
<2.0% |
20 |
2.63 - 3.12 |
20 |
0.98 - 2.85 |
RBC |
20 |
0.41 - 1.09 |
<2.0% |
20 |
1.14 - 1.63 |
20 |
0.52 - 0.97 |
HGB |
20 |
0.48-0.6 |
<1.0% |
20 |
0.45-1.16 |
20 |
0.45-1.03 |
HCT |
20 |
0.66 - 1.29 |
<2.0% |
20 |
1.17 - 1.65 |
20 |
0.54 - 1.12 |
MCH |
20 |
0.56 - 0.89 |
<1.5% |
20 |
1 - 1.69 |
20 |
0.69 - 1.22 |
MCHC |
20 |
0.63 - 1.03 |
<1.5% |
20 |
0.96 - 1.81 |
20 |
0.67 - 1.13 |
MCV |
20 |
0.47 - 0.57 |
<1.5% |
20 |
0.42 - 0.85 |
20 |
0.48 - 0.62 |
RDW |
20 |
1.96-3.2 |
<3.5% |
20 |
2.12-4.37 |
20 |
1.74-2.07 |
PLT |
20 |
2.45 - 3.43 |
<5.0% |
20 |
2.78 - 5.03 |
20 |
1.84 - 1.93 |
MPV |
20 |
1.16 - 1.35 |
<5.0% |
20 |
1.22 - 2.11 |
20 |
0.59 - 1.35 |
LYM% |
20 |
2.83 - 4.79 |
<5.0% |
20 |
3.61 - 5.2 |
20 |
2.28 - 5.73 |
LYM# |
20 |
3.09 - 4.58 |
<5.0% |
20 |
4.11 - 5.12 |
20 |
2.97 - 7.69 |
MON% |
20 |
7.47 - 8.75 |
<15.0% |
20 |
9.52 - 14.74 |
20 |
4.15 - 6.48 |
MON# |
20 |
6.93 - 8.27 |
<15.0% |
20 |
10.16 - 16.34 |
20 |
4.78 - 6.31 |
NEU% |
20 |
1.38 - 1.45 |
<3.0% |
20 |
2.24 - 4.54 |
20 |
0.74 - 3.75 |
NEU# |
20 |
1.57 - 2.43 |
<3.0% |
20 |
3.57 - 5.44 |
20 |
1.55 - 5.8 |
EOS% |
20 |
10.3 - 12.6 |
<25.0% |
20 |
8.9 - 18.7 |
20 |
5.09 - 36.09 |
EOS# |
20 |
10.24 - 12.28 |
<25.0% |
20 |
9.13 - 1928 |
20 |
5.23 - 42.95 |
BASO% |
20 |
19.5 - 22.15 |
<40.0% |
20 |
45.16 - 51.19 |
20 |
14.73 - 26.63 |
BASO# |
20 |
18.21 - 22.15 |
<40.0% |
20 |
51.03 - 55.78 |
20 |
13.98 - 28.42 |