Hewlett Packard 5890 A

Seriennummer: 018902
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
Hewlett Packard GC/MS 5890A/5970B plus. GC with split /splitless injector. 230 V. 50 Hz, 2200 W. Autosampler 7673A with tower 18593A, Controller 18594A. Ionization gauge controller 59822A. Tekmar Capillary Interface. Tekmar LSC 2000 Purge & Trap Sample Introduction System. Chrompack flowmeter FlowMet 500th Edwards e2m2 backing pump. Pentium-I computer. Monitor. Keyboard. Mouse. ChemStation Rev. A.03.02 software. Royalty-G1030 60071st Library NBS/EPA /MSDC Data Base, SEQ: Sequencing. To operate nitrogen liquid is needed.
siehe Storeview
Maggiori Informazioni
Objektnummer B00018902
Seriennummer 018902
Nome oggetto Hewlett Packard 5890 A
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Hewlett Packard

Modell:                         5890 II

Kommentar:     Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

HP 5890 Series II and HP 5890 Series II Plus Gaschromatographs

(Note: The HP 5890 II Plus is a version of the HP Series II configured specifically for the use of EPC).

Technical Data

Instrument Dimensions and Weight

Height:                  18-3/8 inches (465 mm)

Width:                   25-7/8 inches (655 mm

Depth:                   20-1/8 inches (511 mm)

Weight:                 90 pounds (41 kg)

Power Requirements:

Voltages:              120/200/220/240

Range:                  +5, -10% each

Frequency:           47.5-66 Hz

Consumption:       2200 VA max

Output:                 7500 Btu/hr max

Environmental

Operating range is: 0-55°C ambient (20-27°C optimum)

5-95% humidity (50-60% optimum)

Heated Devices

Five heated zones standard: Two detectors

                                               Two inlets

                                               One auxiliary

Methods stored:                      Two

Flow Sensor (not available with EPC or Series II Plus)

Range.-                0-35 sccm [sccm = standard cc/minute]

Accuracy:             ± 3 sccm für He and H 2

                            ± 5 sccm for N 2 and ArCH 4

Extended range:   100-150 sccm

Accuracy:             ±15 sccm

Detector Signal

For external processing by a recorder, integrator, or computer:

Signal Path

Signal Bandwidth

Minimum Peak Width*

INET digital

4 Hz

0.32 sec

0-1 mV analog

~ 4 Hz**

**

0-1.1 V analog

2.6 Hz

0.50 sec

* That can be calculated accuratey by an external measuring device (e.g., integrator) operating at ≥ 4-Hz bandwidth frequency.

**Actual bandwidth depends on the input impedance of the measuing device.

Standard Inlets on the HP 5890 Series II

Split/Splitless Capillary

Paked witb Septum Purge

Temperature-Programmable Cool On-Column Capillary

Split/Splitless Capillary

•            Range to 400°C in 1°C increments

•           Back-pressure design permits independent adjustment of split flow rate without affecting column flow, 0–30 psi head pressure gauge and regulator standard; 0–15, 0–60, and 0–100 psi regulators and gauges also available

•            Septum purge built in at 3 ml/min

•            Accepts columns up to 1.2-mm od

•            Accepts 114-inch glass column for on-column injection

•            Multimode design includes split and splitless injection

•            Air fan built into mainframe to assist in cool-down of inlet

•            Splitless purge time variable in 0.01-min elements

Packed with Septum Purge

•           Range to 400°C in 1°C increments

•           Flow control/forward-pressure design; 0–100 psi head pres­sure gauge standard; 0–10 and 0–60 psi gauges also available

•            Septum purge built in at 1.5 ml/min

•            On-column injection available with configuration A, 1/4-inch od glass columns

•            Individual liners for use with 114-inch metal columns as well as for Series 530-µ columns

•           Liners available for use with replaceable glass inserts

•            Air fan built into mainframe to assist cool-down of inlet

Tempera ture-Program mahle Cool On-Column Capillary

•            Temperature-programmable to 450°C with up to three ramps at up to 100°C/min; also avail­able with oven track mode

•           Forward-pressure design, 0–30 psi head pressure regulator and gauge standard; 0–10, 0–60, and 0–100 psi regulators and gauges also available

•            Septum purge built in at 14 mI/min.

•            Accepts columns with 0.32- to 1.2-mm od (min id = 0.2 mm)

•            Automated injection onto 250-p, 320-1p, and 530-p capil­lary columns with HP 7673A

•            Air fan built into mainframe to assist cool-down of inlet; optional cryogenic cooling

Detectors

Thermal Conductivity Detector

Electron Capture Detector

Flame Ionization Detector

Nitrogen Phosphorus Detector

Flame Photometric Detector

Thermal Conductivity Deteotor Range to 400°C

•            Single-filament (single caluran) design has fluidic switching of reference and analytical carrier flows; a passivated tungsten­rhenium filament is used in a 3,5-µl pell, operating at a constant temperature dif erence relative to the deteotor block temperature

•            Minimum detectable: <400 pg/ml carrier—equivalent to <1 ppm neon in 1 ml air

•            Linear dynamie range: < ± 5% over 10 5 range

•            Digital gain setting time-programmable through the keyboard

Conditions: detector 100°C, 45 ml/min switching and 30 ml/min analytical flow of helium, propane Sample

Electron Capture Detector

•            Range to 400°C

•            A coaxial design with a 15 mCi source (555 MBq) of Ni-63 plated an the inferior of the lower block

•            Constant current mode of operation features switoh selection of pulse parameters for using either nitrogen, hydrogen, helium, or argon/methane oarrier gas

•            Minimum detectable level: <0.04 pg/sec lindane

•            Dynamic range: >10 4 for lindane

Conditions: detector 250°C, 60 ml/min nitrogen carrier

Flame Ionization Detector

•            Range to 450°C

•            Grounded jet and current limited design for operator safety

•            Push-button Flame ignition Fused silica columns insert within 2 mm of the jet tip

•            Sensitivity:

>18 mCoul/gm carbon: nitrogen oarrier, 0.018-in. id jet

>15 mCoul/gm carbon: helium carrier, 0.018-in. id jet

>22 mCoul/gm carbon: nitrogen carrier, 0.011-in. id capillary jet

>18 mCoul/gm carbon: helium carrier, 0.011-in. id capillary jet

•            Minimum detectable: <5 pg carbon/sec, nitrogen carrier at S/N=2

•            Linear dynamic range: < t 10% over a 10 7 range with 0.018-in, id jet

Conditions: column flow 50 ml/min, 45 ml/min Fit, 650 ml/min air, propane sample

Nitrogen Phosphorur Deteetor

•           Range to 400°C

•            Minimum detectable:

<0.4 pg Nilsec as azobenzene

<0.2 pg P/sec as malathion

•            Dynamic range: 10 4 (N and P)

•            Selectivity:      35,000 to 1: g N/g C (as octadecane)

75,000 to 1: g P/g C

Conditions: 30 ml/min column flow, 3 m1/min H 2 , 80 mi/min air

Flame Photometric Detector

•            Range to 300°C

•            100—530 µ id capillary columns fit through the transfer line to the base of the flame

•            Two combustion modes: air/hydrogen or oxygen/hydrogen

•            Detector signal display to view when flame is lit

•            Push-button flame ignition

•            Sulfur mode:   Sensitivity to 20 pg S/second Range

10 3 Selectivity

10 5 g S/g C

•            Phosphorus mode: Sensitivity 0,9 pg P/second

Range 10 4

Selectivity 10 6 g P/g C

Column Oven

• Usable volume:      11 in. x 12 in. x 6.5 in. (h x w x d)

                                279 mm x 305 mm x 165 mm (h x w x d)

• Column span:        228.5 mm, 9 in. (coil size)

  •                                                  Automatic cooling under processor control

  •                                                  Operatmg range:   4°C above ambient to 450°C:

- 80 to 450°C with cryogenic cooling

                                • Setpoint entry: 1°C for temperatures

                                                    0.1°C for programm rates

• Programming:        Rates 0.1 to 70°C per min

                                650 min maximum run time

Three ramps with initial/final holds

*Achievable rates depend on zone temperature, voltage and columns.

Technical Performance

Accuracy (true temperature relative to setpoint)

Specification:   ±1% (°K) from 4°C above ambient to 450°C

Stability (effect of ambient change on actual temperature)

Specification:       <0.01°C for 1°C ambient change

Calibration (setting true temperature at a setpoint)

Oven can be recalibrated to ± 0.01°C with appropriate instrumentation

Gradients (temperature variations within a column)

Specification: less than 2°C within a 9-in. coil anywhere within the operating range

Gruppo prodotti: GC / MS