Soldé

Hewlett Packard 19395 A

Seriennummer: 008115
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Hewlett Packard Headspacesampler Modell 19395A. Mit Autosampler.Transferline. Controller.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00008115
Seriennummer 008115
Nome oggetto Hewlett Packard 19395 A
Stato Archived Product

Gruppo prodotti: HPLC-Miscellaneous

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Hewlett Packard

Modell:                         19395 A

Kommentar:     Dokumente engl.

     

Sample vials of either 10 or 20 mL capacity may be                 With the HP 19395A headspace sampler all setpoints can be used in the headspace sampler. The carousel is                             stored in a method, including vial temperatures the number of

immersed in a silicone oil bath operating from                          injections per vial, pressurization, venting, sampling time, and

ambient + 15° to 150°C.                                                             conditioning times.

Front and TopViews

Consisting of two discrete units standing side-by-side, the front and top views of the HP 19395A show the following features:

Programmer Unit:                   Contains keyboard and display components which contain electronics for controlling the sampler unit - - numeric and LED displays, general purpose keys, parameter keys, autotest module.

Sampler Unit:                          Contains components - - flow controllers, pressure regulators, pressure gauges, and valves controlling pneumatic power and sampler gas flows. It also contains the thermostated bath, sample carousel, and mechanics for sampling from the sealed vials.

Environmental Considerations

The HP 19395A will operate within the temperature range 10 C to 40 C, or under the relative humidity range of 5 to 95%; however, an environment comfortable for human habitation (reasonably. constant temperature and humidity conditions) is recommended for optimum performance and instrument longevity.

Exposure to corrosive substances (whether gas, liquid, or solid) may affect materials used in HP 19395A and should be avoided.

Location

For the HP 19395A alone, a conventional laboratory bench having an unobstructed surface about

39 cm (16 inches) deep by 56 cm (22 inches) wide and capable of supporting at least 30 kg (66 lhs), is adequate.

The HP 19395A is about 41 cm (16 inches) high - - the area above site selected should be free of shelves or other overhanging obstructions. Such obstructjons limit access to the top of the instrument, and may also prevent adequate cooling.

If other devices (chromatograph recorder, integrator, etc.) are to be placed on the same bench, area and load bearing requirements must be proportionately greater.

Power Considerations

Line Voltage . The HP 19395A Headspace Sampler is configured to operate from one of the following line voltage supplies:

*      115 VAC single phase (+10%, -10%), 50 to 60 HZ, 400 VA max.

*      220 VAC single phase (+10%, -10%), 50 to 60 HZ, 400 VA max.

      Operating voltage is configured according to the original power option ordered

(115V for no option, 220V for option 002).
GENERAL DESCRIPTION

INTRODUCTION

The HP 19395A Headspace Sampler provides automatic analysis of up to 24 samples within the temperature range (ambient +15 C) to 150 C.

Samples are placed in glass vials of either 10 or 20 ml capacity (nominal) which are sealed using a septum and crimped metal cap. The vials typically have a 13mm opening, which is the size to which rigid samples must be cut.

The vials are therinostated in a carousel mounted in a silicon oil. bath.

SUMMARY OF FEATURES

*     The sampler can operate independently of the gas chromatograph when connected to a separate gas source.

*     A remote-start cable permits coordination hetween the CC and the Headspace Sampler. When in the “Remote“ mode, the GC will con­trol the sampler.

*     A binary coded decimal (BCD) cable (optional) transfers the vial number to the gas chromatograph or to the integrator, for printing on a report.

*     A complete set of operating set points for a headspace method may be stored as a “method“; four methods can be stored, and will be pro­tected for several hours in the event of   power failure.

*     The methods can be programmed to analyze samples in the carousel un­der different conditions.

*     Multiple injections from the same vial may be made by using the standard or “multiple headspace extraction“ technique.

*     Pressurization of the vial is optional, and is determined by the operator when programming the method.

*     A 1 ml loop is supplied, however a 3 ml sample loop is available to increase the volume of sample injected.

*     The HP 19395A may be controlled by external devices:

a)    Two contact closures or another method to pull a high line low are required - - one to start an injection, and the other to ro­tate the carousel one position.

b)    Using the optional RS-232-C capability, all set points and the injection sequence can be controlled by an external computer.

Part of labexchange logo
Search engine powered by ElasticSuite