Hewlett Packard 1090 Serie II

Seriennummer: 021262
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
Hewlett Packard/1090 Agilent HPLC sistema M Series II. Composto di UV / Vis 79883AX rivelatore. Forno a colonna. Pompa ternaria. Campionatore automatico. Valvola a 6 vie. Loop del campione. 220 V. 50 Hz 750W. Interfaccia HPIB. Computer. Monitor. Tastiera. Mouse. Software installato sul computer. Per far funzionare l aria compressa (max. 5 bar) ed elio (max. 1 bar) è obbligatorio.
siehe Storeview
Maggiori Informazioni
Objektnummer B00021262
Seriennummer 021262
Nome oggetto Hewlett Packard 1090 Serie II
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Hewlett Packard

Modell:                         1090 II

Kommentar:     Dokumente engl.

The elements of a basic liquid chromatography (LC) system are shown in Figure 1-1. A liquid sample is taken from a mixture to be analyzed and introduced to a part of the system that is at elevated pressure. The sample is then transported to a separator by the flow in the sytem. In LC, the separator is called the column and consists in most gases of a tube filled with porous material called the stationary phase. A liquid, called the mobile phase, flows through the tube between the particles of stationary phase material.

The components in the sample become distributed differently between the mobile and stationary phases because they have different interactions (physical and chemical) with each phase. You can select the nature and strength of the interactions by your choice of phases. The components move with different speeds through the column, depending an their affinity for the different phases, and so they elute from the column at different times: their retention times. By changing the composition of the mobile phase during the elution, a gradient analysis, it is possible to analyze a wider variety of compounds in a given time than would be possible under constant conditions.

After the separator, or separators, the column effluent enters the detector, which measures a physical or chemical property of each, now relatively pure, compound and creates a proportional electronic signal. By calibrating with a standard mixture of known compounds, the nature of the compound in the mixture can be elucidated. The quantity of the relevant compounds in the mixture can be calculated by integration of the signal.


Choosing a suitable place

Temperature                        5 - 40°C (40 - 104° F)

Humidity                              < 95% (non-condensing)

Line voltage                         100 - 120 VAC +5%, -10% or

                                           220 - 240 VAC +5%, -10%

Line frequency                     50 Hz (48 - 55 Hz) or

                                           60 Hz (57 - 66 Hz)

Line disturbance                   Surges and sags must not exceed ±20% of normal line voltage.    Voltage must return to normal within 20 ms.

                                           Line transients:

                                           > 10 µs pulse width and > 50% of normal rated voltage may        produce instrument malfunctions.

Power consumption              750 VAC maximum

Dimensions                   70 cm x - 60 cm x 52 cm

                                           (28" x 26" x 20") (width x height x depth)

Weight                         60 - 80 kg (132 - 176 lbs) depending on the configuration.

Gas Supply                   Pure helium (> 99.9%) at 0 - 0.5 bar (0 - 7.5 psi)

For                              Compressed air at 5 bar (75 psi)

auto-injector                 < 10 µm filter grade.