Hewlett Packard 1090

Seriennummer: 019145
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
Hewlett Packard HPLC sistema 1090i DAD 1040A. Forno a colonna per max. 5 pilastri. Campionatore automatico con 100 posizioni. Sistema ternario. Interfaccia HPIB. Degassamento connessione. 220 V. 750 W. Linseis scrittore L200E
siehe Storeview
Maggiori Informazioni
Objektnummer B00019145
Seriennummer 019145
Nome oggetto Hewlett Packard 1090
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Hewlett Packard

model:                   1090

annotation:           Dokumente engl.

 

 

 

 

 

System Overview

 

 

 

General

The HP 1090 Liquid Chromatograph is an Integration of single modules. The Solvent Delivery System (SDS) delivers flow rates from 1 microliter/min up to 5m|/min per channel by true volumetric displacement. This permits 1%-99% gradients with better than 1% precision even at 100 microliter/min. The SDS has fast response for high-speed gradients and low delay volume for micro bore gradients. Each solvent channel has a Metering Pump that takes the solvent in from a reservoir and meters it into the Low Pressure Compliance which acts as the mixing chamber. With the High Pressure Pump, a high frequency membrane pump, pressures up to 400 bar are generated and flow is delivered to the system via a High Pressure Dumper. Flow ripple is removed and system pressure is measured in this item.

 

The Automatic Injector can be programmed to inject volumes from 0.5 microliters up to 250 microliters (250 microliter syringe required). During the injection cycle flow from the SDS is bypassed to the injection system by the use of a Rotary Valve Unit. A sample loop is loaded with the amount of sample programmed. Switching the Valve Unit again brings the sample onto the column.

 

The Automatic Sampler, combined with the Automatic Injector, allows fully automated injection from up to 100 bottles. Access is random and analyses can be run in any sequence and with any method.

 

The Heated Column Compartment insures temperature homogeneity in the column by pre-heating the solvent in a 2 microliter capillary and by heating the surrounding air in the compartment at the same time. The heat exchanger maintains a temperature precision of +/-0.5°C around setpoint in a range from 15°C above ambient to 100°C.

 

The Filter-Photometric Detector allows programmable wavelength switching. A filter wheel gives a choice of 7 wavelengths per analysis from 200 to 540 nm. Switching time is under 2 seconds with no offset. Detector response time can be set to three different values. Lamp current of the Deuterium Lamp can be selected high or low. Two analog outputs, each with a range of 0V to 1V (0.5V/AU) and 0V to 100mV (switch on ADA board), are available. The Integrator output has high resolution. For recorder output a low resolution is used. In addition this output is programmable in % offset and attenuation (only FPD).

 

The Diode Array Detector measures absorbance in a wavelength range of 190 to 600 nm. Details of operation and can be obtained from the Operating Manual section DAD.

 

The HP85 User Interface is suitable for any system configuration. lt gives the user a single communications point for all modules. HP-IB is the communications link to LC hardware and computer peripherals.

 

 

 

System Operation

Operation of all LC modules integrated into the HP 1090 mainframe is observed and monitored by a two processor system located on the Controller Board (CTL). Almost all modules are connected to the controller via an Interface or driver board which is connected to the 1090I/O Bus. Only some few items get a single control signal from an I/O port or provide a status signal directly to an I/O port or an analog signal to a circuit on the CTL.

 

The operator interacts with the HP 1090 via the HP85 which is displaying status and actual values on the one hand. lt sends setpoints and commands to the HP 1090 on the other hand. Connection to the 1090I/O Bus is made with an HPIB Interface Board (IBU) that matches the HP1B protocol to the HP 10901/0 Bus. Status and Error signals are also displayed on the System Keyboard at the front of the HP 1090. In addition, POWER, PUMP and DETECTOR can be switched ON and OFF manually. The analysis can be started and stopped with pushbuttons from the keyboard as well.

 

The Solvent Delivery System (SDS) consists of two different pumps (isocratic configuration) which are coupled together in line. The Metering Pump System takes solvent in from a reservoir and meters it into the Low Pressure Compliance (LPC). The LPC acts as a mixing chamber and serves as a temporary storage device for solvents of each functioning channel during the time where the High Pressure Pump delivers flow to the system and no solvent can go into its cavity. Two stepper motors are required to drive the Metering Pump; the one to move the two piston pumps (servo motor) and the other to turn a Rotary Valve (valve motor). Actual movement of the servo motor is sensed by a shaft encoder and compared with setpoints provided by the controller on the Servo Control Board (SCT).

 

The resulting error signal is combined with additional information from the controller on the Motor Driver Board (MDR) where an according signal for the servo motor is generated. The valve switching motor is also controlled by the MDR, whereby feedback on proper execution is provided by limit switches and sent to the controller via a circuit on the MDR. Control for flow channel B and C (binary and ternary configuration respectively) is in the same way as described above for channel A. The pressure in the Low Pressure Compliance is sensed and an electrical signal is provided by the Low Pressure Transducer (LPT) and sent to the controller.

 

The High Pressure Pump delivers the solvent to the column. Operation is started and synchronized with a pulse from the controller to the Primary Board (PRI) where the pump motor is connected to line power. An interrupt signal for further use on the CTL is derived by a Pump Stroke Signal Board (PSS) that senses the movement of the pump motor. This signal is also sed to synchronize switching of the Metering Pumps with the pressure stroke of the High Pressure Pump. Flow on the high pressure side is damped in the High Pressure Damper and the pressure is measured at the same time with the High Pressure Transducer. This signal is also sent to the controller.

 

A Manual Valve Injector can be used to place the sample onto the column. Moving the valve to the inject position provides a start pulse to the controller. No other signals are required for operation.

 

The Automatic Injector uses the Injector Sampler Driver Board (ISD) to interface with the controller. Signals to drive valves and stepper motors are connected through the Injector Control Board (ICO). All sensed positions and states are fed to the ISD also through the ICO.

 

The Automatic Sampler is controlled in exactly the same way as described for the Automatic Injector. Even the driver board (ISD) is the same. Functions of the Sampler Control Board (SCO) are the same as for the ICO, however the hardware design is different.

 

Oven fan, oven heater and associated sensors, responsible for temperature control of the Heated Column Compartment are connected to the controller via the Oven Interface Board (OVI).

 

Four external contacts, one of which is a contact closure and three are switching 24V, located on the External Contacts Interface Board (ECI), are controlled directly from the respective I/O ports on the CTL.

 

Even though any available detector for the HP 1090 is a built-in module there is only a minimum number of connections to the controller. For the Filter Detector only some Status and Error signals are transferred. Data manipulations on the detector signal are made in the detector processor itself. Chromatographic signals are available at the detector outputs. The Diode Array Detector transfers status messages via a single cable to the System keyboard. lt also uses this connection to be turned ON or OFF. Data transfer to mass storage devices uses the HPIB connection to HP85. Two analog signals are generated in the detector module and are available at the detector rear panel.

 

 

 

 

 