Hettich Rotanta 460 R
| Objektnummer | B00005582 |
|---|---|
| Seriennummer | 005582 |
| Nome oggetto | Hettich Rotanta 460 R |
| Stato | Archived Product |
Gruppo prodotti: Centrifughe Refrigerate
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Hettich
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

ROTANTA 460 R
Rationelles, ergebnisorientiertes Arbeiten hat sowohl in Forschungs- als auch Routinelabors oberste Priorität. Mit fortschrittlicher Labortechnik hilft die gekühlte ROTANTA 460 R, Prozesszeiten wesentlich zu verkürzen. Hohe Leistung und ihr umfangreiches Zubehörprogramm garantieren schnelle und reibungslose Abläufe im Laboralltag.
Mit einer maximalen Kapazität von 3 Litern pro Lauf bewährt sie sich in Kliniken und Einsendelabors ebenso wie in den F&E Abteilungen der Life Sciences. Für die Probenverarbeitung in der Klinischen Chemie steht eine große Auswahl an Adaptern für unterschiedlichste Gefäßtypen zur Verfügung. Biotechnologie, Molekularbiologie und die pharmazeutische Industrie schätzen die ROTANTA 460 R besonders wegen ihres autoklavierbaren und aerosoldichten Zubehörs. Für die Reinigung von DNA/RNA bietet die vielseitige gekühlte Tischzentrifuge einen Filterplattenrotor mit einer RCF von 6.446.
Mit der komfortablen C-Steuerung gestaltet sich die Bedienung des Geräts einfach und bequem. 98 Programmspeicherplätze können belegt werden. Falls erforderlich, lässt sich die Zentrifugierlaufzeit umstellen die Zählung kann entweder bei Drücken der Starttaste oder bei Erreichen der Nenndrehzahl beginnen. Spezielle, bei den dafür vorgesehenen Rotoren hinterlegte Bremsrampen ermöglichen die Zentrifugation von Blutbeuteln.
Modellvarianten der gekühlten ROTANTA 460 R mit Anschluss für Stickstoffspülung
(Bestell-Nr. 5660-20), in Heizen-Kühlen-Version bis 90 °C (Bestell-Nr. 5660-50) oder in
Heizen-Kühlen-Version mit Anschluss für Stickstoffspülung (Bestell-Nr. 5660-70) auf
Anfrage.
Max. Kapazität:
im Ausschwingrotor: 4 x 750 ml
im Winkelrotor: 6 x 250 ml
Max. Drehzahl
: 15.000 min-1
Max. RCF
: 24.400
Maße (H x B x T):
456 x 770 x 706 mm
Gewicht:
ca. 133 kg
Kühlung:
stufenlos regelbar von 20 °C bis + 40 °C
Häufig eingesetzte Rotoren:
Ausschwingrotor für 4 x 750 ml (90°), max. RCF 5.063
Winkelrotor für 30 x 1,5 / 2 ml (45°), max. RCF 24.400
Winkelrotor für 6 x 250 ml (25°), max. RCF 14.025
Ausschwingrotor für max. 12 Mikrotiterplatten (90°), max. RCF 6.446