Soldé

Hamilton Microlab 500

Seriennummer: 010432
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Hamilton precisione pipettaggio Microlab serie 500. ProgrammierbarerDiluter con due siringhe.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00010432
Seriennummer 010432
Nome oggetto Hamilton Microlab 500
Stato Archived Product

Gruppo prodotti: Pipette

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Hamilton

Modell:            Microlab 500

Kommentar:   Dokumente engl.

The Microlab 500 diluters and dispensers are precision fluid measuring instruments based on Hamilton’s world-renowned syringe technology.

The semi-automated instruments use positive displacement to achieve highly accurate and precise fluid aspirations and dispenses.

A simple touch-of-a-hand probe button or a tap-of-a-foot switch actuates the precision syringe drives to fill or dispense a desired volume of fluid. Supplied with a 1mL and 10mL syringe as standard.

Hamilton Microlab500 Series as a Diluter

Simple dilutions can be made in three easy steps (after priming the instrument) as shown in Figure 1:


Figure 1:
A simple dilution

Step 1: Fill the left syringe with the programmed amount of solvent (diluent) from the reservoir.

Step 2 : Aspirate the programmed amount of concentrated sample into the end of the probe using the right syringe.

Step 3: Dispense the sample and solvent into a vial to complete the dilution.

In addition to simple dilutions performed on all MICROLAB 500 diluters, models ML530B, ML532BP and ML531C instruments can also perform serial, and multi-sample/reagent (or internal standard addition) dilutions.

In comparison with volumetric glassware, the MICROLAB 500 provides extraordinary cost savings and sample preparation time reductions. Its accuracy tolerances far exceed those of volumetric flasks, graduated cylinders, measuring pipettes, and burettes.

Only transfer pipettes can shower better accuracies. The precision of the ML500 meets or exceeds that of Class A glassware, especially when operator imprecision is considered; that is, the automated nature of the ML500 eliminates operator-to-operator inconsistencies. Read or download the full report

Read or download a colour brochure on the Microlab 500 diluter/dispensers.

Hamilton Microlab500 Series as a Dispenser

Dispenses, including titrations, can be made in two easy steps (after priming the instrument) as shown in Figure 1.

Figure 1: A simple, dual dispense

Step 1: Fill the syringe(s) with the programmed amount of reagent from the reservoir.

Step 2: Dispense the programmed amount(s) into a microwell plate, test tube, vial, etc. to complete the dispense cycle.

The key features are

·        Save time during sample preparation

·        Eliminate technician-to-technician method variability

·        Simplify compliance to method documentation requirements for regulations and standards, such as those of the EPA, FDA (GLP, GMP), and ISO

·        Perform aliquot, serial, simple, or titrate dispenses

·        Reduce reagent and solvent consumption

·        Achieve certified accuracy within ± 1.0% and precision within + 0.2%, traceable to N.I.S.T.