Soldé

Gilson 849

Seriennummer: 012343
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00012343
Seriennummer 012343
Nome oggetto Gilson 849
Stato Archived Product

Gruppo prodotti: Sistemi di Pipettaggio

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Gilson

Modell:            849

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

Designed for parallel injection onto an HPLC or LC/MS system. Deliver high-throughput capacity with outstanding speed and performance. Modules are the ideal choice for high-throughput injection onto FIA/MS

•     Allows four or eight simultaneous injections - ideal for parallel HPLC or MUX systems

•     Configure with Rheodyne’s RV700-100 or RV700-112 (849) valves depending upon your application needs

•     Accommodate injection loop sizes as small as 5 µL up to 5 mL for analytical to preparative LC applications

•     Calibrated tubing is specifically engineered to ensure precise parallel injections

Specifications

Manufacturing Standards             Meets applicable safety and EMC certification           standards; UL and CE certified

Available Sample Loops                5, 10, 20, 50, 100, 200 or 500 µL; 1, 2 or 5 mL

Available Valves                             Rheodyne RV700-100 or Rheodyne RV700-112

Carryover                                        RV700-100 Valve

                                                         • <1 ppb with the following rinse volumes:

                                                         – injection port rinse volume=250 µL

                                                         – rinse station rinse volume=500 µL

                                                         RV700-112 Valve

                                                         • <0.05% with the following rinse volumes:

                                                         – injection port rinse volume=1000 µL

                                                         – rinse station volume=1000 µL

Dead Volume                                  Injection Port                             Dead Volume* (µL)

                                                        0.7 mm OD probe tip                  11

                                                        1.3 mm OD probe tip                  15

                                                        1.5 mm OD probe tip                  14

                                                         * From probe to valve (including calibrated tubing)

Front Panel                                     Power light, 4 or 8 INJECT lights and 4 or 8 LOAD lights

Liquid-Contact Materials               304 and 316L stainless steel, alumina ceramic, FEP,           PEEK

Power Requirements                     Frequency: 50–60 Hz

                                                         Voltage: 90–240V; mains voltage fluctuations not to exceed ±10% of the nominal voltage

                                                         Current rating: 2.0A for 90–120V or 1.0A for 220–240V         (849); 3.0A for 90–120V or 1.5A or 220–240V (889)

Precision                                         RV700-100 Valve

                                                         • Partial loop fill: CV <2.0% with a 500-µL syringe and 10-     µL partial loop fill in a 20-µL injection loop

                                                         • Total loop fill: CV <5.0%

                                                         RV700-112 Valve

                                                         • Partial loop fill: CV <2.0% with a 5-mL syringe and 1-mL    partial loop fill in a 2-mL injection loop

                                                         • Total loop fill: CV <5.0%

Communication Interface              GSIOC

Valve Switching Speed                 RV700-100: <135 mS

                                                         RV700-112: <370 mS

Dimensions (w x d x h)                  61 x 18 x 13 cm (24 x 7 x 5 in.)

Weight (with installed valves)      7.7 kg (17 lbs.) with four installed valves

                                                         11.4 kg (25 lbs.) with eight installed valves

Part of labexchange logo
Search engine powered by ElasticSuite