Gilson 155

Seriennummer: 013077
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00013077
Seriennummer 013077
Nome oggetto Gilson 155
Stato Archived Product

Gruppo prodotti: HPLC-Detectors (UV/VIS)

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Gilson

Modell:            155

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

Gilson 155 UV/UVIS Detector

Description

The Gilson 155 and 156 UVNIS Detectors are microprocessor-controlled absorbance detectors that provide dual wavelength detection. Both detector models are compatible components of a Gilson modular HPLC system. And, the 155 Detector with its front panel control is also compatible with other commercially available HPLC systems.

The 155 Detector can be controlled via its front panel or via TRILUTIIoN'"" LC Software. The 156 Detector must be controlled via TRILuTION LC since it does not have an integral front panel display. For information an how to control the 156 Detector, refer to the TRILuTioNTM" LC Software User's Guide.

Optics

Gilson's optical design lets you monitor absorbance at any wavelength from 190 to 700 nm.

The detector has a sensitivity range of 0.001 to 2.0 AUFS (Absorbance Units, Full Scale).

Display

The 155 Detector software is self-guiding.

All parameters, values and commands appear an the four-line display.

All of your options are displayed above the six soft keys. Press a soft key to choose and carry out a command. Numeric entries are made using the keypad.

Features

You can choose from the following modes to specify detection conditions and basic operating parameters:

•            single wavelength

•            dual wavelength

•            scan wavelength

•            setup

•            status

•            fite

Technical Specification

Autozero range

Suppresses up to 1.0 AU with 5 mm flow cell installed

Contact control

Event and autozero inputs: remote contact closure can be activated by other Instruments or the Computer

Three channels output data to a recorder.

Display

Four-line display shows modes, parameters, commands and data (155 only)

Drift

After one hour at constant temperature: 3.0 x 10 -4 AU/hour

Flow sensitivity

4.0 x 10 -4 AU for flow step of 2.0 mL/min to 0.5 mL/min with methanol

Front panel

LAMP ON/OFF hard key, LED indicator Iights for POWER, UV, VIS, REMOTE, and ERROR (155 and 156)

Six soff keys, HELP, ESC and CLEAR hard keys, arrow keys, numeric hard keys, and ENTER hard key (155 only)

Lamp warm-up

One hour maximum time

Lamps

UV Iamp: Deuterium, warranted for 750 hours or 180 days shelf-life Visible Iamp: Tungsten/halogen Iamp, warranted for 500 hours

Linearity

1%, when value is within sensitivity range of 0.001 to 2.0 AU

Flow cells

The following quartz flow cells are available:

Pressure

Flow cell

Pathlength

Volume

psi

bar

MPa

Analytical

5 mm

12 µL

500

34.5

3.45

Preparative

0.05 mm

0.16 µL

500

34.5

3.45

Preparative

0.2 mm

0.7 µL

500

34.5

3.45

Capillary

8 mm

35 nL

3000

200

20

Microbore

2 mm

1.6 µL

500

34.5

3.45

Preparative

SFC*

0.5 mm

2.0 µL

10000

689.7

68.97

SFC*

5 mm

10µL

10000

689.7

68.97

*Stainless steel

Manufacturing standards

Meets applicable Safety and EMC certification standards; UL and CE certified.

Monochromator

Dual beam, steppermotor-driven

•            Range: 190 to 700 nm

•            Spectral bandwidth: 9 nm

•            Setting accuracy: ±2 nm

•            Setting precision: ±0.2 nm

Noise with air block installed

220 nm, short term, peak to peak; 2.0 x 10 -5 AU/cm

254 nm, short term, peak to peak; 2.5 x 10 -5 AU/cm

350 nm, short term, peak to peak; 10.0 x 10 -5 AU/cm

415 nm, short term, peak to peak; 8.0 x 10 -5 AU/cm

520 nm, short term, peak to peak; 6.0 x 10 -5 AU/cm

650 nm, short term, peak to peak; 4.0 x 10 -5 AU/cm

Operating modes

Single wavelength, dual wavelength, scan wavelength, status, setup, and fite

Peak width

0.0 or 4.0 to 99.0 seconds

Physical spare

26.5 x 43.5 x 15.6 cm (10.4 x 17.1 x 6.2 in) requirement

Power requirements

Frequency: 50 to 60 Hz

Voltage: 90-240V

Current rating: 1.5A for 90-120V or 1.0A for 220-240V

Online switching regulation of line input from 80 to 260V AC

Sensitivity Range

0.001 to 2.0 AU. Sensitivity is adjustable in increments of 0.001 AU.

Software control

You can issue commands via the GSIOC or RS-232

You can use the GSIOC or RS-232 to do the following:

•            Select all detection parameters

•            Program parameter changes during run to optimize detection

•            Send digital detector output

Static RI sensitivity

Methanol versus cyclohexane at 270 nm: 5.0 x 10 -3 AU

Temperature sensitivity

3.0 x 10 -4 /°C for temperature change from 21 ° to 24°C

Weight

8.6 kg (19 lbs.)