Genevac Mega 980SII
Objektnummer | B00010736 |
---|---|
Seriennummer | 010736 |
Nome oggetto | Genevac Mega 980SII |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Genevac
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.
Mega Evaporation Systems
Genevac's new Series II Mega Systems provide ultra high throughput solvent evaporation.
Accommodating samples in an extensive variety of microtitre or smaller formats, Mega systems are also designed to handle formats langer than a microtitre plate. Common examples are fraction collector racks from LC/MS systems, larger reaction blocks or proprietary sample formats. Evaporation Performance is similarto HT systems.
Common applications include
HPLC or LC/MS Purification
High Throughput Screening & Compound Storage
High Throughput Synthesis
Sample Handling & System Operation
Access to the evaporation chamber is via a top opening, powered aluminium lid. Samples are loaded into large sample swings, which are fixed to a high strength rotor. The evaporation chamber is constructed from corrosion resistant hard anodised aluminium. For high boiling point solvents (e.g. DMSO & NMP), the chamber and lid can be heated to 45°C to prevent solvent condensation during the evaporation process. This gentle heating can also be used to aid evaporation. Coolheat lamps provide most of the heat required for rapid evaporation of solvents. A powerful vacuum system ensures low pressure and low sample temperatures during evaporation. Similar to HT systems, vapours pass from the evaporation chamber into a VC8000T series cryopump/condenser. High boiling point vapours are condensed under vacuum, very volatile vapours pass into the CVP vapour vacuum pump and from the pump exhaust into a solvent waste condenser.
User interface - simple to use with sophisticated capabilities for optimum evaporation
Genevac Series II systems are easy to use, high performance systems. Evaporation runs are selected by highlighting a nun from a menu on a full colour LCD screen. Each nun has a user-defined description for easy identification. The embedded PC Stores up to 100 runs. This easy to use interface provides very simple and flexible operation, ideal for a multi user environment. A run is selected and started sample temperature control and shut down are automatic. For optimum evaporation settings, numerous parameters can be pre-set and stored for each run. The sophisticated software incorporates many safety interlocks to eliminate the risk of harm to the user, samples or system. Important run parameters are displayed "live" on an LCD screen and can be reviewed after each run. Run parameters can be altered during a run if necessary.
Coolheat technology and SampleGuard temperature control provide rapid evaporation
The systems generally consist of three main components: evaporator, cryopump and vacuum pump. Powerful gold plated Coolheat infra red lamps in the evaporator provide the heat required for very rapid evaporation of all commonly used solvents, including DMSO and waten. A high vacuum pumping system consisting of the CVP 100 vapour vacuum pump and the VC8000 cryopump creates low pressure and low sample temperatures during the evaporation process. The unique dual temperature SampleGuard temperature controller prevents the samples from exceeding the pre-set temperature ceiling by controlling the infra red heat input. In normal Operation sample temperatures need not exceed 40°C. Built-in pressure control and an optional extra set of Coolheat infra red Iamps can be utilised to accelerate the evaporation of water and other slow drying solvents.
High imbalance and sample weight limits ensure maximum flexibility and safe use
The Mega systems will operate safely with imbalanced loads of at least 200 g. A safety switch will shut the system down in a controlled way if this limit is exceeded. A visual warning will appear on the LCD display. The Auto-Balancing Mechanism Option can be fitted for loads over 200g imbalance.
Dri-Pure Anti-Bumping System prevents sample loss and cross contamination
Some solvents and solvent mixtures can "bump" unpredictably even under standard centrifugal evaporation conditions, causing sample loss and cross contamination. The optional Dri-Pure system prevents solvent "bumping" with problematic samples. This patented system combines a gentle, ramped application of vacuum and increased rotational speed at specific pressures to eliminate the sample loss and cross contamination caused by solvent "bumping".
Corrosion Proof Vacuum System
The Genevac designed CVP vapour vacuum pump is standard on all HT and Mega systems. Using a unique pumping principle, the CVP pump provides high vacuum, requires no oil changing or regular maintenance and is corrosion proof against all commonly used acids (including Trifiuoroacetic acid).
SPECIFICATION
Technical Data Mega 980/1200
Temperature controls
Control range 1 to 60°C
Control accuracy ± 1.5°C
Control resolution 1°C
Probes 2
Display range -44 to +60°C
Chamber temp range Ambient to 45°C
End of run criteria Timer/IR on:off
Mechanical Data
Max RPM (standard) 900/810
Max RPM (Dri-Pure) 1100/990
Max force 450 G
Drive system Direct
Operating imbalance 200/250
Max sample Ioad 6-9.6 /12-17.6 Kg
IR Iamps 12 / 24
Extra IR lamps Option 6
Vacuum System
Vacuum Pump Genevac CVP 100
Vacuum display 0-1200 mbar
Vacuum control 0-Atmosphere
Vacuum ramp Yes
System ultimate vacuum 0.5 mbar
Auto vacuum vent valve Yes
Condenser Data
Condenser temp -45°C
Vacuum condenser capacity 2 x 8 litres
Exhaust condenser capacity 2.5 litres
Condenser chamber Stainless steel
Condenser drain Manual or auto valve
Condenser level detector Option
Rapid defrost Yes
Continuous running Yes
Auto draining Option
Solvent drain pump Option
Power supply
Standard 2x230v, 50Hz, single phase
Current 21A & 16.8 A Power consumption
980 5.8 kW
Dimensions
Width 1382/1600 mm
Depth 1084/1304 mm
Height (lid closed) 1371/1371 mm
Height (lid open) 2313/2521 mm
Weight 960 / 1300 kg
Chamber dia 980/1200mm
Compressed Air Supply
Pressure Clean, dry air at 6 or 7 bar
Filtration Air filtered to 40 um
Air consumption <10 l/min (free air)
Optional Built in compressor