Soldé

Forte 7590

Seriennummer: 009644
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Forte fibra Moisture Meter Forte 7590 Anno: 1997 Prezzo originale: 31,700, - Euro.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00009644
Seriennummer 009644
Nome oggetto Forte 7590
Stato Archived Product

Gruppo prodotti: Termobilance

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Forte

Modell:            7590

Kommentar:   Dokumente engl. + dt.

GENERAL SYSTEM DESCRIPTION

SYSTEM OPERATION

The Forte Model 590 Series Moisture Measuring System is designed for cones or skeins of yarn and other products. It features moisture measuring and weighing operations. The 590 Series performs instantaneous measurements and compiles complete production records. Data items are Output to a VDT, a printer, and a plant computer port. Data items to each output device can be selected by the operator.

The System has two modes of Operation called Processing Mode and Command Mode which are also referred to as ON-LINE and OFF-LINE respectively. The system starts in the ON-LINE Mode when the power is turned on. In this mode, a product moisture test can be performed and the results will be output to the selected devices. To change production parameters, system parameters, and output parameters, the system must be put into Command Mode.

OPERATING PROCEDURES

The Forte Systems use a variable AC input voltage DC power supply. When power is applied to the supply it determines the AC input voltage. This results in a delay of several seconds between turning on the power with the key switch and having the power button light turn on and the processing mode display appears on the VDT.

The system starts up in Processing Mode (ON-LINE). The system can be toggled between Processing Mode and Command Mode (OFF-LINE) by pressing the ":" key. The system password must be entered to change to Command Mode. In Command Mode a list of the commands is displayed in the upper portion of the screen (see VDT Display 2).

Product, Setup, and System parameters can only be entered from the Command Mode. These parameters should be entered before any processing takes place. The entered data is stored in nonvolatile memory so that it is not lost if power is removed from the system. Lot summary totals are lost if power is removed.

When the system is put ON-LINE, the screen will be divided into two horizontal sections. The current processing Type will be displayed in large numerals on the left in the top section of the screen. The last moisture value will be displayed in large numerals on the right in the top section of the screen (see VDT Display 1). The processing Type defaults to one (01) when the system is powered up. A heading will be shown in the bottom section of the screen. Data will be displayed under the heading as it is generated. Up to 15 lines of data are displayed under the headings. Each new line of data is added at the bottom as the screen scrolls upward. It is not possible to scroll downward to view previously displayed data.


Elektrische Daten    

Leistungsaufnahme                                   230 V Wechselspannung, 50/60 Hz, 1000 Watt

Umweltdaten

Temperatur

                        Während des Betriebs       10° bis 34° C

                        Außer Betrieb                     -10° bis 45° C

Relative Feuchtigkeit

                        Während des Betriebs       20 - 80% relative Feuchtigkeit, nicht kondensierend

                        Außer Betrieb                     5 - 95% relative Feuchtigkeit, nicht kondensierend

Stoß

                        Während des Betriebs       15 g Spitzenbeschleunigung 11 ms Dauer

                        Außer Betrieb                     30 g Spitzenbeschleunigung 11 ms Dauer

Vibrationen                                                 5 bis 2000 Hz

                        Während des Betriebs       0,015 cm Spitze-Spitze 1,0 g max.

                        Außer Betrieb                     0,038 cm Spitze-Spitze 2,5 g max

Mechanische Daten

Gesamtabmessungen

Konsole 590

Höhe                1600 mm

Breite               1220 mm

Tiefe                 711 mm

Gewicht            154,5 Kg

Drucker (mit Stand))

Höhe                889 mm

Breite               635 mm

Tiefe                 457 mm

Gewicht            28,6 Kg

Part of labexchange logo
Search engine powered by ElasticSuite