Finnigan SSQ 710

Seriennummer: 008797
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Finnigan GC / MS Modell SSQ 710.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00008797
Seriennummer 008797
Nome oggetto Finnigan SSQ 710
Stato Archived Product

Gruppo prodotti: GC / MS

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Finnigan

Modell:            SSQ 710

Kommentar:   Dokumente engl.

The Finnigan MAT 700 Series system is a high-sensitivity analytical instrument comprising one or more inlet systems, a mass spectrometer, and a data system. The mass spectrometer consists of an ion source, one or more mass analyzers (two in a TSQ 700, one in an SSQ 700), and an electron multiplier all enclosed in an vacuum manifold. Each mass analyzer contains four metal rods held in a square array. This arrangement is called a quadrupole rod assembly or a quad.

A sample is introduced into the ion source where it is ionized. The ions are then focused into the analyzer assembly where they are separated by mass-to-charge ratio. The ions are then converted into an electrical signal when they are detected by the electron multiplier. The signal is amplified and then passed on for further processing and for display.

All instrument control functions for 700 series instruments, from tuning the instrument to acquiring data, and all data analysis tasks are controlled from a DECstation 2100.

The 700 Series can be operated in a wide variety of scan modes, ionization modes, ion polarity modes, and mass range modes.

Quads can be operated in one of two capacities:

  • as ion transmission devices or
  • as mass analyzers

lonization Modes

Initial ionization of sample molecules occurs in the ion source. In the EI/CI/FAB configuration, the 700 Series offers three ionization modes:

•     EI (electron ionization)

•     CI (chemical ionization)

•     optional FAB (fast atom bombardment) ionization.

In the optional thermospray configuration, three types of ionization are available:

•     thermospray buffer ionization

•     thermospray filament ionization

•     thermospray discharge ionization

The best method of ionization depends upon the application and type of sample to be analyzed.

Mass Range Modes

Two mass ranges are available on the 700 series: the low mass range (10 to 2 000 u) and the high mass range (20 to 4 000 u). In the low mass range mode, unit resolution is obtained throughout the entire mass range. In the high mass range mode, somewhat less than unit resolution is obtained.

In the operation of the system, the ranges scanned by the mass analyzers can be set independently. Thus, both mass analyzers can be set to the low mass range; both can be set to the high mass range; or the first can be set high and the second low.

When the instrument is analyzing compounds with molecular weights of 2 000 u or less, both mass analyzers are set to the low mass range. In this way, unit resolution is obtained for all parent and daughter ions in each of the scan modes.

The SSQ 700 has a single quadrupole rod assembly and two lenses. The rod assemblies and lenses (and the electron multiplier) are mounted on a rail. Ions from the ion source enter the analyzer assembly, are separated by mass-to-charge ratio, and then are passed on to the electron multiplier. For a block diagram of the analyzer assembly, see Figure 7-1.

Figure 7-1. Block diagram of the analyzer assembly (b) SSQ 700

5 kV Dynodes

The SSQ 700 is equipped with a positive ion / negative ion electron multiplier that consists of two conversion dynodes and a continuous dynode electron multiplier (Fig. 8-2) The conversion dynodes are metal surfaces, one maintained at +5 kV and the other at -5 kV.

Figure 8-2. Schematic representation of the SSQ 700 electron multiplier and conversion dynodes


Positive and negative high voltages exist an the respective conversion dynodes continuously when the electron multiplier is on. The nature of the ions being detected is determined by switching the ion-source and analyzer-assembly lens voltages and the quadrupole offset voltages to allow positive or negative ions to be injected successively into the analyzer assembly and mass analyzed. When the positive or negative ions strike their respective conversion dynode surfaces, several secondary particles are produced. These particles then enter the cathode of the electron multiplier and are processed as in the TSQ 700.

SAMPLE INTRODUCTION: GC / TRANSFER LINE

The standard configuration of the 700 Series GC/MS/MS or GC/MS system includes a Varian 3400 Gas Chromatograph (GC) and GC accessory cabinet. The Varian 3400 GC is described in detail in the documentation provided with the GC.

The GC interfaces to the ion source region of the mass spectrometer via a simple transfer line and interface flange. The GC is placed on the GC accessory cabinet. Adjustment of the GC cabinet's four feet allows precise alignment of the transfer line to the EI/CI/FAB ion source within the vacuum manifold.