Soldé

Finnigan AQA

Seriennummer: 016990
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Finnigan Masspectrometer AQA. With nitrogen generator. Edward pump.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00016990
Seriennummer 016990
Nome oggetto Finnigan AQA
Stato Archived Product

Gruppo prodotti: Spettrometri di massa

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Finnigan

model:                   AQA

annotation:           Dokumente engl.

 

 

The Finnigan AQA TM MS detector has been specifically designed and engineered for liquid chromatographic detection using Atmospheric Pressure Ionization (API) and Mass Spectrometry (MS) technology. These technologies can provide sensitive and selective detection of organic molecules.

Interfacing High Performance Liquid Chromatography (HPLC er LC) and MS provides the separation scientist with one of the most powerful analytical tools available. Both LC and MS have developed to a point whereby they represent two of the most important techniques in characterizing and detecting organic compounds. Although the potential benefits of interfacing LC to MS have been clearly recognized for mang years, producing a truly automated `connect and use" Interface has proven to be a challenging task.

Atmospheric Pressure Ionization (API) techniques now provide highly sensitive detection using conventional to capillary LC flow rates on bench­top MS detector systems. LC/MS works with typical solvent compositions, whether the separation is achieved by isocratic or by gradient elution.

Historically, LC/MS has been compatible only with volatile buffer systems using modifiers such as trifluoroacetic acid, formic acid and acetic acid. Phosphate buffers, although extensively used in LC Separations, were not suited to LC/MS due to rapid blocking of the ion sampling region caused by the deposition of involatile phosphate salis. The self-cleaning AQA API source allows for extended periods of Operation in LC/MS with chromatographic buffers such as phosphates er ion pairing agents and Samples in dirty matrices.

API using Electrospray (ESI) or Atmospheric Pressure Chemical Ionization (APCI) Interfaces has proved to be invaluable in meeting sensitivity requirements in quantitative methods. lt can also provide structural Information, which is complementary to techniques such as NMR and infra red spectroscopy.

This introduction focuses on the principal components of the System.

 

System Overview

The Finnigan AQA MS detector is an integral part of the LC detection system. Key points of the system are:

•        The sample is introduced into the ion source using an LC system, possibly through a column.

•        In an API MS detector, the part of the source where ionization takes place is held at atmospheric pressure, giving rise to the term Atmospheric Pressure Ionization (API).

•        In ESI, the sample is ionized in the liquid phase, whilst in APCI, ionization occurs in the gas phase. In both Gases, efficient desolvation is needed to remove the solvents from the sample.

•        Ions, now in the gas phase, are passed through the mass analyzer and are collected at the detector.

•        The detected Signal is sent to the data system and stored ready for processing.

 

The main features of the Finnigan AQA MS detector are:

•            Dual ESPAPCI orthogonal probe

•            Self-cleaning API-LC/MS Interface

•            Flow-focused source, eliminating the need for electrostatic focusing

 

Schematic diagram of the Finnigan AQA API inlet, analyzer and detector system.

 

The LC eluent is ionized at the API probe wich the resulting ions flow­focused into a hexapole RF lens. The quadrupole mass analyzer filters the ions before detection.

 

Part of labexchange logo
Search engine powered by ElasticSuite