Archivio

ESCO AVC-6D1

Seriennummer: 017120
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
ESCO/Envair Verticale cleanbench Airstream AVC-6D1. Pure product protection. Vertical stream of air. Working width: 1800mm. Brand new! Manufacturer guarantee. Option: UV-Lamp UV30A (190E). Connections for gas, vaccum, nitrogen, oxygen and water (each 250E). Underframe with adjustable feet SAL-4B0 (450 E) Polycarbonate front cover FC AVC5D (350E) Alternative width: 600, 900, 1200 and 1500 mm
siehe Storeview
Maggiori Informazioni
Objektnummer B00017120
Seriennummer 017120
Nome oggetto ESCO AVC-6D1
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Esco

model :                   AVC-6D1

annotation :           Dokumente engl.

 

 

 

Esco Airstream Vertical Laminar Flow Clean Benches offer proven protection for your samples and processes where operator protection is not required. Vertical laminar flow offers certain tangible advantages over horizontal flow clean benches (which may be the convention in some parts of the world), such as lower energy consumption (40% of conventional systems) levels through the use of exclusive motorized impeller technology and less airflow turbulence (especially when large objects are used in the work zone). In fact, the negative pressure filter mounting system employed on these models is widely recognised to be superior to that of conventional horizontal flow clean benches.

 

Features

·                      ISO Class 4 air cleanliness within work zone as per ISO 14644.1 (equivalent to Class 10 as per US Federal Standard 209E, 10 times "cleaner" than the usual Class 100 classification on clean benches offered by the competition).

·                      High-quality polyester pre-filter and main ULPA filter with a typical efficiency of 99.9997% at MPPS and 99.9998% at both 0.3 and 0.12 microns provide the best product protection in the world; typical main ULPA filter lifespan is more than 3 years depending on the usage of the clean bench.

·                      Mini-pleat separatorless ULPA filter technology reduces energy consumption and delivers increased laminar airflow uniformity for better product and cross contamination protection.

·                      Integral filter metal guard on both sides prevents accidental damage to ULPA filter; seamless filter gasket is permanently molded on the filter frame and will not deteriorate over time; aerosol (DOP/PAO) challenge test port included.

 

Specifications AVC-6D1

Model No.

Standards Complied

External
Dimensions (mm)

Internal
Dimensions (mm)

Airflow
Velocity (Inflow)

Airflow
Velocity (Downflow)

Electrical

AVC-6D1

AS1386.5, CSA22.2 No.1010.1-92, EN 1822, EN-1822, EN61010-1, IEC61010-1, IEST-RP-CC001.3, IEST-RP-CC002.2, IEST-RP-CC007, IEST-RP-CC-034.1, ISO 14644.1, UL 61010A-1, UL-C 61010A-1, US Federal Standard 209E

1950 x 764 x 1280

1880 x 700 x 720

-

0.45(m/s) /
90(fpm)

220-240V,AC, 50Hz,1ø

Esco offers a variety of options and accessories to meet local applications. Contact Esco or your local Sales Representative for ordering information.

Support Stands

· Fixed height, available 711 mm (28") or 860 mm (34")

o With leveling feet (SPL)

o With casters (SPC)

· Adjustable height, hydraulic range 711 mm (28") to 860 mm (34")

o Manual or electrical lift (SPM)

o With casters


Electrical Outlets and Utility Fixtures

· Electrical outlet, ground fault, North America

· Electrical outlet, Euro/ Worldwide

· Petcock (air, gas, vacuum)

o North America (American) style

o Euro/Worldwide style DIN 12898, DIN 12919, DIN 3537


Cabinet Accessories

· Germicidal UV lamp

· Transparent front cover (recommended when UV lamp is used)

· PVC armrest

· Height-adjustable lab chair

· Ergonomic foot rest

· IV bar, with hooks

Airstream® Vertical Laminar Flow Clean Benches Airflow Picture

· Room air is taken in from the top of the clean bench through a disposable pre-filter with 85% arrestance; this serves to trap larger particles and increase the life of the main filter.

· Air is forced evenly across the ULPA filter(s); the result is a stream of clean laminar air within the work zone of the clean bench; this dilutes and flushes all airborne contaminants from the interior.

· A nominal filter face velocity of 0.45 m/s or 90 fpm ensures that there is a sufficient number of air changes within the enclosed area of the clean bench in order to maintain cleanliness.

· The purified air travels across the working zone of the clean bench in a vertical, unidirectional stream and leaves the main work chamber across the entire open front of the clean bench and through Auto-Purge™ slots at the back wall of the workzone. Auto-Purge™ slots are designed to eliminate air turbulence and the possibility of dead- air corners in the workzone.

pdf Catalog
pdf French Catalog
pdf German Sellsheet
pdf Spanish Catalog
pdf Vietnamese Sellsheet

 

· ISO Class 4 air cleanliness within work zone as per ISO 14644.1 (equivalent to Class 10 as per US Federal Standard 209E, 10 times "cleaner" than the usual Class 100 classification on clean benches offered by the competition).

· High-quality polyester pre-filter and main ULPA filter with a typical efficiency of 99.9997% at MPPS and 99.9998% at both 0.3 and 0.12 microns provide the best product protection in the world; typical main ULPA filter lifespan is more than 3 years depending on the usage of the clean bench.

· Mini-pleat separatorless ULPA filter technology reduces energy consumption and delivers increased laminar airflow uniformity for better product and cross contamination protection.

· Integral filter metal guard on both sides prevents accidental damage to ULPA filter; seamless filter gasket is permanently molded on the filter frame and will not deteriorate over time; aerosol (DOP/PAO) challenge test port included.

Esco offers a variety of options and accessories to meet local applications. Contact Esco or your local Sales Representative for ordering information.

Support Stands

· Fixed height, available 711 mm (28") or 860 mm (34")

o With leveling feet (SPL)

o With casters (SPC)

· Adjustable height, hydraulic range 711 mm (28") to 860 mm (34")

o Manual or electrical lift (SPM)

o With casters


Electrical Outlets and Utility Fixtures

· Electrical outlet, ground fault, North America

· Electrical outlet, Euro/ Worldwide

· Petcock (air, gas, vacuum)

o North America (American) style

o Euro/Worldwide style DIN 12898, DIN 12919, DIN 3537


Cabinet Accessories

· Germicidal UV lamp

· Transparent front cover (recommended when UV lamp is used)

· PVC armrest

· Height-adjustable lab chair

· Ergonomic foot rest

· IV bar, with hooks

Airstream® Vertical Laminar Flow Clean Benches Airflow Picture

Airflow

·                      Room air is taken in from the top of the clean bench through a disposable pre-filter with 85% arrestance; this serves to trap larger particles and increase the life of the main filter.

·                      Air is forced evenly across the ULPA filter(s); the result is a stream of clean laminar air within the work zone of the clean bench; this dilutes and flushes all airborne contaminants from the interior.

·                      A nominal filter face velocity of 0.45 m/s or 90 fpm ensures that there is a sufficient number of air changes within the enclosed area of the clean bench in order to maintain cleanliness.

·                      The purified air travels across the working zone of the clean bench in a vertical, unidirectional stream and leaves the main work chamber across the entire open front of the clean bench and through Auto-Purge™ slots at the back wall of the workzone. Auto-Purge™ slots are designed to eliminate air turbulence and the possibility of dead- air corners in the workzone.

pdf Catalog
pdf French Catalog
pdf German Sellsheet
pdf Spanish Catalog
pdf Vietnamese Sellsheet

 

Gruppo prodotti: Cappe a Flusso Laminare

Non è stato trovato alcun prodotto corrispondente alla selezione.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure