I JavaScript sembrano essere disabilitati nel tuo browser. Per una migliore esperienza sul nostro sito, assicurati di attivare i javascript nel tuo browser.
Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.
We would be pleased to take over the professional installation of your laboratory devices!Please contact us.
Benefit from the installation by us in more than one way:
Manufacturer warranty
optional installation of equipment for immediate and safe use of equipment
Attractive rental and leasing offers conserve your budget
Use our free call-back-function
The manufacturer’s warranty terms apply for new devices. We will gladly inform you individually and in accordance to the chosen new device.
Play it safe! We are pleased to offer you the installation of your laboratory equipment. Our qualified technicians install the device on your desired date in the laboratory, so that you can work quickly and safely with your new laboratory equipment.
* Campi obbligatori
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country
Possible payment methods
Comment
DE, AT, CH
Payment by invoice, payment in advance
Payment by invoice is only possible for corporate clients.
NL, BE, LU
Payment by invoice is only possible for corporate clients
Other countries
Payment in advance
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
All articles are used articles, except an article is listed especially as a new device.
Status
Condition
Immediately available
Used
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.
Published
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.
New device
new
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.
Manufacturer: Labexchange
Model: ECS02
The following illustrations and descriptions refer to the device model and come from brochures.
They are not the scope of delivery. For the exact scope of delivery please refer to the offer text.
Technical specifications
ECD2600 UV-VIS Detector
Detector with continuously variable wavelength in the range of 190-600 nm and a noise level ±3·10-6 AU.
Unit offers high-speed sampling up to 100 Hz and wavelength autocalibration. AC 05 analytical cell is
ECO2099 Column oven with heating
This column oven allows temperature stabilization above ambiet temperature.A big compartment room can accommodate up to 3 columns with length up to 25 cm.
OverheatingSecurity-Fuse prevents destruction of temperature sensitive columns. Temperature range is ambient temperature +5°-99 °C.
CLARITY Chromatography Software
This system is fully controlled by Clarity Chromatography software, which is also a part of delivery. Clarity software complies CFR21GLP requirements.
ECP2010 Analytical HPLC Pump
This isocratic pump works with Gradient Box ECB2004 as a quaternary gradient pump. Flow rate range is 0.01-10 ml/min and pressure limit at 40 MPa.
Unit software includes new learning algorithm for pulsation suppression and many testing and diagnostic functions
ECB2004 Gradient Box with Degasser
Box is suited for handling liquids in ECOM gradient systems. It accommodates a container for solvent bottles, built-in highefficiency vacuum degasser and four-way gradient valve. Up to four solvent lines may be degassed simultaneously by one unit. Fourway gradient valve is controlled from the pump ECP2010.
Detector ECD2600 ECD2800
Wavelength range 190-600 nm 190 - 800 nm
Spectral half width 6 nm
Adjustment accuracy ± 1 nm
Reproducibility ± 0.5 nm
Light source Deuterium lamp Deuterium + halogen lamps
Noise (test cell, 254 nm, TC 2s, 10 Hz) ± 3 · 10 -6 AU
Drift (test cell, 254 nm) 1 x 10 & sup4; AU / h.
Time constant 20 - 10 000 ms
Scanning speed up to 100 Hz
Digital output 1 V / AU
Analog output 1 1x configurable
Wetted materials are dependent
from one cell - quartz glass, PTFE, stainless steel, PEEK
Communication RS232, Ethernet (LAN)
Display, keyboard VFD 140x32 pixels, 10 buttons
Power supply 100-240V 50 / 60Hz 100VA
Dimensions (W x H x D) 280 x 135 x 498 mm (11.02 x 5.12 x 18.23 in)
Weight 9 kg
ECO 2099 column oven
Operating temperature range
ambient temperature +5°C - 99° C
temperature stability
± 0.2 ° C
Reproducibility of temperature
temperature accuracy
± 2 ° C
communication
RS232, Ethernet (LAN)
Display, keyboard
VFD 140x32 pixels, 10 pushbuttons
power supply
100-240 V 50/60 Hz 250 VA
Heated space inside dimensions (W x H x D)
328 x 54 x 42 mm
Dimensions (W x H x D)
280 x 135 x 498 mm
Weight
14 kg
Pump ECP2010
flow rate
0.01-10.00 ml / min.
pumping system
two pistons dia. 1/8 "connected in series
Maximum operating pressure
40 MPa (5800 PSI, 400 bar)
Accuracy of flow rate (1 ml / min, 12 MPa, H 2 O)
± 2%
Repeatability of the flow rate (1 ml / min, 12 MPa, H 2 O)
± 0.5%
Accuracy of pressure measurement
Adjustable lower pressure limit
0.0-39.0 MPa
Adjustable upper pressure limit
1.0 - 40.0 MPa
Number of valves *
4 (A, B, C, D)
Setting of component concentrations *
0.0 - 100.0%
Wetted materials
Stainless steel, sapphire, KEL-F, gaskets **
RS232, Ethernet (LAN), USB
100-240 V 50/60 Hz 100 VA
10 kg
ECB2004 Gradient Box with degasser
Il tuo Labexchange-Team sarà lieto di aiutarvi:
Christian Schmid Laboratory and analysis, Laboratory equipment, Life science
Hubert Sauter Spectroscopy, Chromatography