Dynex MRX TC II
Objektnummer | B00018385 |
---|---|
Seriennummer | 018385 |
Nome oggetto | Dynex MRX TC II |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: Dynex
model: MRX
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Specifications
Software Specifications MRX e Standard: Revelation MRX Program
Hardware Specifications No. of filters 6
Performance Read: cycle time Single Wavelength: < 4 seconds; Dual Wavelength: < 6 seconds
405 to 850nm Wavelength
Range Dynamic range -0.100 to +4.000 OD
Linearity 0.000 to 2.000 OD: ± 1.0%; 2.001 to 3.500 OD: ± 1.5%
Filter band width (FWHM) 10 nm ± 2 nm
Center Wavelength Accuracy ± 2 nm
Precision 0.000 to 2.000 OD: 0.2% CV or 0.005 OD whichever is greater
2.001 to 3.000 OD: 0.6% CV
3.001 to 3.500 OD: 1.0% CV
Accuracy 0.000 to 3.500 OD: 2.5% or 0.005 OD whichever is greater
340 to 400 Wavelength
Range (Option) Dynamic range -0.100 to +3.000 OD
Linearity 0.000 to 2.500 OD: ± 2.0%
Filter band width (FWHM) 18nm ± 2 nm
Center Wavelength Accuracy ± 2 nm
Precision 0.000 to 2.000 OD: 0.6% CV or 0.005 OD whichever is greater
2.001 to 2.500 OD: 1.0% CV .
* Precision is the mean Coefficient of Variation (CV) figure for all wells on a plate that has been read 20 times in succession. (Measured by the manufacturer at 410nm in the visible range and 340nm in the UV range).
Interface Computer
Interface USB 1.0/2.0 compatible
Electrical Light source 75W tungsten halogen lamp
Mains input 100 to 120V or 200 to 240V 50 to 60 Hz (switch selectable)
Power consumption 175 VA
Fuses There are no internal user-replaceable fuses. The power supply contains a CSA approved 20x5mm, 4A cartridge fuse with a voltage rating of 250V in
the primary circuit. If the fuse blows, contact the service center.
Physical/Environmental Conditions
Weight 10.kg (22.lb)
Dimensions D390 x W360 x H220 mm (15.4 x 14.2 x 8.7 inches)
Operating Temperature 10 – 40°C
Operating Humidity 10 – 90% RH
Storage Temperature 0 – 50°C
Storage Humidity 10 – 90% RH
Altitude < 2000m