Dionex ED 40

Seriennummer: 014518
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00014518
Seriennummer 014518
Nome oggetto Dionex ED 40
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                DionexDionex

Modell:              ED 40ED 40

Kommentar:      Dokumente engl.Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

Overview

The ED40 Electrochemical Detector measures current resulting from the application of potential (voltage) across electrodes in flow­through cells. Depending an the method by which the potential is applied and the current measured, several different properties of the flowing solution can be determined. These measurements help answer the major questions analytical chemists ask: What's in it, and how muck is there?

Of course, other detectors are used in high performance liquid chromatography (HPLC). The UV-visible absorbance detector dominates all other forms of detection. Sensitivity is excellent for mang analytes, especially aromatic species, and transparent mobile phases are readily available. However, there are numerous analytes that haue very poor absorbance and are not detected with sufficient sensitivity by UV absorbance. Most of these nonchromophoric molecules are aliphatic organic molecules and inorganic ions. Low wavelength UV detection can be used, but at a loss in selectivity. Refractive Index detection can also be used. However, maintaining a stable baseline can be difficult, and RI detection is less sensitive and substantially less selective than UV detection.

Fortunately, a wide variety of nonchromophoric molecules can be detected with good or excellent sensitivity by one of several forms of electrochemical detection. These molecules include carboxylic, sulfonic and phosphonic acids; alcohols, glycols, aldehydes, and carbohydrates, primary, secondary, tertiary, and quaternary amines; sulfates, sulfoxides, thiols, sulfides, and mercaptans; and inorganic anions and cations. In addition, when compared to UV absorbance detection, electrochemical detection provides substantial improvements in sensitivity and selectivity for amine and hydroxy-substituted aromatics such as catecholamines.

The ED40 Electrochemical Detector is housed in a single-unit DX 500 enclosure (sec Figure 2-1). The detector is designed to be stacked an top of other DX 500 units, up to a maximum height of four units. Figure B-1 in Appendix B illustrates the recommended stacking configuration for DX 500 systems.

ED40 Enclosure

Electrical

Main Power        85 to 270 Vac, 47/63 Hz; 40 W Max, 25 W typical. The ED40 power supply is auto-sensing and requires no voltage adjustment.

Fuse                   Two 3.15 amp fast-blow IEC127 fuses (P/N 954745)

Analog Output    User-selectable full-scale Output of 10, 100, or 1000 mV

Environmental

Operating          

Temperature      4 °C to 40 °C (40 °F to 104 °F)

Operating          

Humidity             5 to 95% relative humidity, non-condensing

Physical

Dimensions        22.5 cm wide x 17.0 cm high x 42.0 cm dep

                          (8.8 in wide x 6.6 in high x 16.4 in deep)

                          6 cm (2.4 in) clearance required behind the detector

Weight                8.2 kg (18 lb)

Display and Keypad

Display               Liquid crystal display with adjustable backlighting

Keypad               26-button keypad for entering commands and numerical values for screen parameters

Detector

Range                0.01 µS to 3000 µS, full scale (Conductivity)

                          50 pC to 200 µC (Integrated Amperometry)

                          50 pA to 300 µA (DC Amperometry)

Temperature     

Compensation   0.0 to 3.0% per °C (Conductivity)

Cell Drive           Variable 8 kHz square wave (Conductivity)

                          ±2.04 V (DC and Integrated Amperometry)

Local                 

Operation          Front panel controls and display Status of all functions.

Remote             

Operation          Control of 4 of 7 functions via TTL or Relay contacts.

DX LAN              All functions controlled by PeakNet Software an a PC

Operation           connected to the ED40 via the DX LAN Interface (optional).

Conductivity Cell

Cell Body           PEEK
Active Volume    1.0 µL

Maximum          

Pressure            2.0 mPa (300 psi)

Electrodes          316 stainless steel

Amperometry Cell

Cell Body            Titanium (counterelectrode)

Active volume     ~ 0.2 µL

Maximum          

Pressure            0.7 mPa (100 psi)

Working             

Electrodes         Gold, Silver, Platinum, Glassy Carbon

Reference         

Electrode            Combination pH–Ag/AgC1

SRS Power Supply

Supply Current   50, 100, 300, 500 mA @ 1.5 to 7.5 V

Over-Voltage     
Alarm                  8.5 V

Over-Tempera-

ture Alarm          40 °C

DS3 Detection Stabilizer

Operating           25 °C to 40 °C (50 °F to 104 °F)

Temperature

Warm-up Time 10 minutes (typical)

Under- or            Message displayed when not at set temperature

Over-Tempera‑

ture Alarms

Gruppo prodotti: HPLC-Detectors