Soldé

Dionex DX 500

Seriennummer: 010043
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Dionex HPLC-System DX 500. Chromatographie Oven LC 30. Autosampler AS 50. Gradient Pump GP50. Detector PDA 100. Universal Interface UI20. Shodex RI 101. YoC: 2002.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00010043
Seriennummer 010043
Nome oggetto Dionex DX 500
Stato Archived Product

Gruppo prodotti: Cromatografia Ionica

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:             Dionex

Modell:           DX 500

 

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 

  

 

Specifications

Signals

Up to nine, each defined by a sample wavelength and bandwidth.

 

Noise

< ±25 }SAU, 250 nm 4-nm bandwidth

 

Drift

< 1 mAU/hr, 250 nm, empty cell

 

Wavelength Range 195 – 600 nm

 

Wavelength Accuracy ± 1 nm

 

Resolution

1 nm Digital

 

Spectral Acquisition

Selectable, 240, 320, 640, 1280, 2000 ms

 

Light Source

Deuterium; 1000 hrs

 

Flow Cells

Stainless Steel: 8-µL volume, 10-mm path, 5 MPa (750 psi) max

 

Titanium (optional): 8-µL volume, 10-mm path, 5 MPa (750 psi) max

 

Prep (optional): variable volume and path, 2 MPa (300 psi) max: 0.8-µL volume, 0.1-mm path 1.6-µL volume, 0.2-mm path 4.0-µL volume, 0.5-mm path

 

High pressure (optional): 3-µL volume, 6-mm path, 40 MPa (6000 psi)

 

Diode Array Thermostat

3-stage temperature control:

Off, Low (37 °C), High (47 °C) Important for dark-current control

 

Operating Temperature Range

10–35°C

 

Dimensions (h x w x d)

20 cm (7.9 in.) x 26 cm (10.2 in.) x 52 cm (20.5 in.)

 

Weight

18 kg (401b)

 

Power Requirements

120 V ac, 2 A, 60 Hz;

or 220 V ac, 1 A, 50 Hz;

or 240 V ac, 1A, 50 Hz


Autosampler AS 40

 

Specifications

Sample Delivery Method:

Displacement

 

Capacity:

11 cassettes of either six 5-mL or eight 0.5-mL PolyVials

 

Vial Size:

Nominal volume of 0.5 or 5 mL

 

Filter Pore Size:

20 µm

 

Minimum Volume Delivered:

0.17 mL from 0.5-mL vials; 1.7 mL from 5-mL vials

 

External Control:

Relay closure

 

Injections Per Vial:

1, 2 or 3 samples may be delivered from each vial

 

Type of Loading:

Loop: Delivers sample rapidly to sample loop

Concentrator: Delivers sample against back pressure of up to 100 psi (690 kPa) at approximately 0.4 mL/min (0.5-mL vials) or 1 mL/min (5-mL vials)

 

Mode of Sampling:

Proportional: delivers volume inversely proportional to number of injections per vial

Constant: Delivers fixed volume independent of the the number of injections per vial

 

Bleed:

On: Displaces excess sample and

 

any trapped air through bypass valve before sampling

Off: Delivers sample and any trapped air directly to injection valve

 

Dimension, (H x W x D):

11.3 x 14.3 x 17.5 in.

(28.7 x 36.3 x 44.5 cm)


Detector ED 40

 

The versatile Dionex ED40 Electrochemical Detector provides the three major forms of electrochemical detection: Conductivity, and DC and integrated amperometry. An additional mode is voltammetry, which can be used to determine the potentials used for amperometry operation. The ED40 can also be used to monitor pH during amperometric operation; and temperature during conductivity operation.

 

Features

The ED40 includes all of the features of the CD20 conductivity detector, plus:

•    An advanced electrochemical cell design that incorporates a 1-mm diameter working electrode for a high signal-to­noise ratio.

•    Four working electrode options: gold, platinum, silver, and glassy carbon.

•    Low volume cell for low dispersion.

•    Corrosion resistant titanium flow path and counter electrode.

•    Combination pH-Ag/AgC1 reference electrode that minimizes baseline shift with pH gradients.

•    Easy remote mounting of amperometry cell.

 

Conductivity Electronics & Flow Cell

Same as CD20 Conductivity Detector.

 

Amperometry Electronics

Noise: 1 pA (DC amperometry); 20 pC (integrated amperometry)

Potential Ranges: ±2.00 V in 0.01-V increments.

Control Modes: Local or remote via relay closures, TTL, or by PeakNet Software via DX LAN.

 

Amperometry Flow Cell

Electrodes:

Interchangeable working electrode­gold, platinum, silver, or glassy carbon. Counter electrode—titanium.

Reference electrode—pH-Ag/AgCI com­bination.

 

Wetted Materials: PEEK, Titanium, Kel-F, polyetherimide, EPR, glass, high density polyethylene (HDPE), and working elec­trode material (gold, platinum, silver, and glassy carbon).

 

Cell Volume at Working Electrode:

 

Maximum Operating Pressure: 0.7 MPa (100 psi).

 

Output Control

Filter: 0 to 10 s response time.

Full-Scale Analog Output Ranges: Conductivity-0.01 gS to 3000 gS Integrated amperometry—50 pC to 200 gC. DC amperometry—50 pA to 300 p.A.

Offset: To full-scale for each range.

Analog Signal Output Voltage: 0.01, 0.1, or 1 V.


Gradient Pump GP 40

 

The Dionex GP40 Gradient Pump is a dual processor-controlled gradient solvent delivery system designed to blend and pump mixtures of up to four mobile phase components at precisely controlled flow rates. The selected mobile phase composition may be delivered either isocratically or as a linear or exponential gradient.

The GP40 is configured as either a standard bore or a microbore pump.

 

Features

  • Dual processors (a microprocessor for module common functions and a Digital Signal Processor (DSP) dedicated to fulltime pump control) provide superior flow control, stability, and accuracy for low noise.
  • Computer-aided design of flow path provides extremely small void volumes for accurate, sharp gradients with minimal delays.
  • DSP firmware provides compressability compensation for accurate flow rates and eluent proportioning regardless of pressure level and viscosity.
  • Dual pump heads reduce pulsation, allowing high sensitivity detection with pulse sensitive detectors.
  • Built-in vacuum degas Option provides sealed pressurized in-line degassing for best reproducibility, lowest backgrounds, and protection of delicate solvents from contamination and breakdown.
  • Isocratic proportioning or binary, ternary, or quaternary gradients can be programmed. In addition to a linear gradient, four concave and four convex gradients can be chosen.
  • User-selectable pressure mode or flow mode (no pressure feedback).
  • User-selectable high and low pressure limits automatically stop the pump in the event of leaks, flow restrictions, flow blockages, or an empty eluent reservoir.
  • Integral piston rinsing prolongs seal lifetime by preventing salt crystallization on the piston.

 

GP40 Pump Hydraulics

Construction: Chemically inert, metal-free PEEK flowpaths are compatible with all aqueous eluents of pH 0–14 and reversed phase solvents.

 

Type: Dual reciprocating pistons, micropro­cessor-controlled constant stroke, vari­able speed.

 

Control Modes: Local or remote via relay closures, TTL, or by PeakNet Software via DX LAN.

 

Flow Rate Setting Resolution: 10 µL/min

 

Maximum Pressure: 35 MPa (5000 psi) for both microbore and standard pump heads.

 

Pressure Alarm Limits: Upper limit 0–35 MPa or 0–5000 psi in 1 unit (MPa or psi) incre­ments; lower limit settable to up to one unit lower than high limit setting.

 

Flow Accuracy: ±0.5% of setting.

 

Flow Precision: Better than 0.2% for micro­bore pump; better than 0.1% for standard pump.

 

Eluent Selection: Four different mobile phase components; each can be propor­tioned from 0 to 100%.

 

Proportioning Accuracy: ±1% for standard pump; ±2% for microbore pump.

 

Pressure Pulsation: 0.2% of system pressure (in pressure mode).

 

Physical Specifications

Power Requirements: 90 - 265 V ac, 47 - 63 Hz (power supply is auto-sensing no voltage adjustment required).

 

Operating Temperature Range: 4 to 40°C (40 to 104°F); cold room (4°C) compatible as long as system power remains on.

 

Operating Humidity Range: 5 - 95% relative, noncondensing.

 

Dimensions: 33.5 cm h x 22.5 cm w x 42 cm d (13.1 in. x 8.8 in. x 16.4 in.)

 

Weight: 16.1 kg (35.3 lb); 19.5 kg (43 lb) with degas option.

 