Archivio

Dionex AS 50

Seriennummer: 017594
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00017594
Seriennummer 017594
Nome oggetto Dionex AS 50
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

manufacturer :       Dionex

model :                   AS 50

annotation :           Dokumente engl.

 

 

 

The Dionex Autoselect AS50 Autosampler precisely delivers from 1.0 to 99.9 µL (in 0.1 µL increments) or 100 to 1000 µL (in 1 µL increments) of sample to an injection valve.

Two types of trays are available for sample vials: one for 2 mL vials and one for 10 mL vials. During sampling, the tray remains stationary and a sampling needle arm moves from vial to vial. Up to 99 injections can be taken from each vial.

The AS50 can be controlled locally, from the front panel keypad and display, or remotely, from a Dionex workstation. The workstation consists of a computer with a Dionex DX-LAN Interface card and PeakNet software installed. Limited remote control is also available, using TTL and relay signals.

The AS50 can be configured with PEEK flow paths and components for ion chromatography (IC) applications, or with stainless steel flow paths and components for high-performance liquid chromatography applications (HPLC).

 

Control Panel

The control panel contains a liquid crystal display (LCD) and membrane keypad (See Section 2.2). The control panel permits manual control of all AS50 functions.

Autosampler Compartment

The autosampler compartment contains a stationary sample vial tray and a sampling needle arm that moves from vial to vial during operation (see Section 2.3).

Sample Temperature Control Option (Not Pictured)

The optional sample temperature control unit mounts under the autosampler and provides uniform heating and cooling of the vial tray. See Seetion 2.3.2 for details.

Syringe and Reservoir Organizer

The organizer an top of the autosampler Nolds the sample syringe, the flush liquid reservoir, the optional prep syringe, and the optional reagent reservoir(s). See Section 2.4 for details_

Chromatography Compartment Option

The optional chromatography compartment houses the components required for a single- or dual-column chromatography system. The components, such as the analytical column(s), cell(s), and suppressor(s), raust be ordered separately from the AS50. See Section 2.6 for details.

Thermal Compartment Option

A version of the chromatography compartment is available that provides heating and cooling of the chromatography components. See Section 2.6.2 for details.

Injection Valve

When the AS50 is configured without a chromatography or thermal compartment, the injection valve is installed in the autosampler compartment. When the AS50 is configured with one of the compartments, the injection valve is installed in the compartment. See Section 2.5 for details.

 

 

 

 

Specifications Autosampler

 

Electrical

Main Power        100 Vac to 240 Vac, 50/60 Hz; 6 amps. The AS50 power supply is main voltage auto-sensing and requires no adjustment.

Fuses                 Two 3.15 amp fast-blow IEC127 fuses (P/N 954745)

 

Environmental/Physical

Ambient Operating       10 °C to 40 °C (50 °F to 104 °F)

Temperature

Operating Humidity      10% to 95% relative humidity, non-condensing

Decibel Level               <60 db (at "A WEIGHING" setting)

Dimension                    58 cm high x 30 cm wide x 46 cm deep (23 in x 12 in x 19 in)

Weight                          < 30 kg (< 65 Ib )

 

Valses (Optional)

Injection              Two-position, six-port, electrically-activated Rheodyne valve

                          IC version: PEEK with Tefzel® rotor seal

                          HPLC version; Stainless steel with Vespel® rotor seal

Column              Two-position, ten-port, elecnicaLly-activated Rheodyne valve

Switching           IC version: PEEK with Tefzel rotor seal

                          HPLC version: Stainless steel with Vespel rotor seal

 

Injection

Injections Per               1 to 99

Vial

Vial Sizes                     0.3 mL polymer vials (P/N 055428, package of 100)

Available                       1.5 mL glass vials (P/N 055427, package of 100)

             10 mL PolyVials (P/N 055058, package of 100)

Variable Volume           1 to 100 µL in 0.1 µL increments

Range                          100 to 1000 mL in 1 µL increments

Injection Loop               IC version: 25 µL standard; other sizes are available

Size                              HPLC version: 20 µL standard; other sizes are available

 

Sample Temperature Control Unit (Optional)

Temperature                4 °C to 60 °C in 1 °C increments at 24 °C (75 °C) ambient, stable to

Control Range              ± 0.2 °C

Operating                     5% to 90% relative humidity, noncondensing

Humidity                       Cooling capacity is slightly reduced at high humidity

Dimensions                  65 cm high x 30 cm wide x 46 cm deep (2.75 in x 12 in x 19 in)

(Sample Temp. +

Autosampler)

Weight                          <38 kg (<81 lb)

(Sample Temp. +

Autosampler)

 

Chromatography Compartment (Optional)

Dimensions                  50 cm high x 17.5 cm wide x 40 cm deep (20 in x 7 in x 16 in)

Weight                          9 kg (20lb)

 

Thermal Compartment (Optional)

Dimensions                  50 cm high x 173 cm wide x 40 cm deep (20 in x 7 in x 16 in)

Weight                          18 kg (40lb)

Temperature                10 °C to 40 °C in 1 °C increments, stable to ± 0.2 °C

Control Range

(IC Mode)

Temperature                10 °C to 80 °C in 1 °C increments, stable to ± 0.2 °C

Control Range
(HPLC Mode)

Ambient                        10 °C to 40 °C (50 °F to 104 °F)

Operating

Temperature

Delay Volume              < 100 µL

 

Gruppo prodotti: HPLC-Autocampionatori