Dani 86.50
Objektnummer | B00011542 |
---|---|
Seriennummer | 011542 |
Nome oggetto | Dani 86.50 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Dani
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.
DESCRIPTION
DANI HSS 86.50 Head Space sampler is a single compact cabinet including:
· The Sampling System
· The Programmer
· The Pneumatic System
The Sampling System
The sampling system is consisting of three main devices:
· The sample vial tray
· The thermostated oven
· The Head space gas transfer device
The sample vial tray
The sample vial tray with 44 seats, is Iocated an the left side of the cabinet and it is driven by a DC motor. The standard vial volume is 20 ml, but the use of special adapters allows the sampling of 10 mI volume vials.
The thermostated oven
The thermostated oven contains a six seat rotating plate vial holder . The maximum operative temperature is 200°C, with an increment of 1°C.
The vial transfer system consists of a mobile fork carried on a bridge. This transfer system withdraws the set vial from the vial tray seat and drops it into the thermostated oven, through an inlet/outlet hole, placed at the top of the oven.
The thumbscrew allows the opening of the oven upper cover.
During the incubation time, the vials can be shaked. The left lateral panel can be removed to accede to the electronic boards.
The Head Space gas transfer device
The Head Space gas transfer device is based on the "VALVE and LOOP" System and it is housed in a thermoinsulated box. The sampling probe, the switching valve and the loop build up the manifold; it is temperature controlled and can operate at a maximum temperature of 200°C, with an increment of 1°C. The transfer of the gas Sample, from the 86.50 to the gas chromatograph, is performed by means of a heated transfer tube. The manifold and the transfer tube are heated to prevent cold spots. At the bottom left side of the unit, the program panel is placed.
On the top of the cabinet are located:
- The Carrier gas pressure reducer knob
- The Auxiliary gas pressure reducer knob
The Programmer
Fully microprocessored, it provides the complete control of the sampling System allowing up to four preprogrammed analytical methods. The analytical method includes all the parameter values (temperatures, incubation time, number of repetitive analysis an the same sample etc.) and the valve timing of all the operative steps (pressurization, sampling, venting etc.).
The PANEL is divided in three sections:
· Valve timing section
· Display section
· Control key section
The valve timing section
The valve timing section allows the Operator to set-up the valves actuation in an analytical cycle.
The display section
The display section includes sixteen alphanumeric characters.
The control section
The control section includes seven keys and live status lamps.
The Pneumatic Circuit
The HSS 86.50 sampling system, consists of a "valve and loop" device, which allows to inject into the GC a precise and known amount of the gas phase contained in the sample vial.
Gas Lines
The gas line feeding the unit is divided in two streams:
- CARRIER including a pressure regulator, the output of which is connected to the port 4 of the switching valve.
- AUX including a pressure regulator, a restrictor, the output of which is connected to the electrovalve "PRESS" and then, through a Tee connection, to the electrovalve "VENT" and to the port 2 of the switching valve.
Pressure evaluation of both gas Iines is provided by an electronic pressure transducer with readout an the display.
Technical Specification
DANI HSS 86.50 HEAD SPACE SAMPLER VIALS
Number of vials 44
Vial material neutral glass
Vial volume 20 ml
10 mI (with adapter)
Vial septa PTFE coated butyl rubber
PTFE coated silicon rubber
Vial aluminium ring
OVEN
Temperature range 15°C above room temperature to 200°C, 1°C increment
Accuracy 0.5 % full scale
Stability ± 0.5°C
Heating electrical, with forced air
MANIFOLD
Temperature range 15°C above room temperature to 200°C, 1°C increment
Accuracy 1.0% full scale
Stability ±0.5°C
Heating electrical
Sampling Valve MV 65/106 HT, 6-port valve
Sampling loop 1 mI volume, nickel
3 ml volume, nickel (optional)
TRANSFER TUBE
Temperature 15°C above room temperature to 220°C, 1°C increment
Accuracy 2.0% full scale
Stability ± 0.5°C
Heating electrical
OVEN CAROUSEL
Number of vials 6 seats
Shaking SOFT, oven stepping motor: 100 steps/sec.
FAST, oven stepping motor: 200 steps/sec.
PROGRAMMER
Microprocessor 8 bit
Control keys START,RESET,LOCK,SET,ACT,UP,DOWN
Operation leds WAIT,READY,AUTOSTART,RUN,LOCK
Valving timing keys and relevant leds : PROBE,PRESS,VENT,VALVE,TEST
DISPLAY
16 character alphanumeric display
PRESSURE CONTROLS
Pressure regulator with digital pressure readout
CONTROL INTERFACES
RS 232 serial communication
BCD output of sample number
CONTROL SIGNAL
Output remote start
AUTODIAGNOSTIC TEST
RAM
ROM
OVEN PROBE
VALVE PROBE
TUBE PROBE
CARRIER PRESSURE
AUXILIARY PRESSURE
UTILITIES
Power supply 220 V (± 10%), 50 Hz, 600 VA
115 V (± 10%), 60 Hz, 600 VA
Fuses 3.15 AT, 250 V (220 V)
6.30 AT, 250 V (115 V)
DIMENSIONS AND WEIGHT
Dimensions 42Wx47.4Hx61.7D cm