Coulter ACT 5Diff
Objektnummer | B00014508 |
---|---|
Seriennummer | 014508 |
Nome oggetto | Coulter ACT 5Diff |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: Coulter
model: ACT 5Diff
annotation: Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
COULTER® AceT TM 5diff AL (Autoloader)
Automated sample processing for walkaway efficiency
The AcT 5diff AL significantly improves sample handling by eliminating manual sample loading a feature that not only saves time, but also lowers operational costs and increases your lab's Overall workflow efficiency. In addition, the Software enables laboratories to upload QC assay values and download IQAP data automatically, which enhances their Quality Assurance program management while requiring less manual manipulation of data.
Easy-to-use data management
Easy quality control fite management
Patient storage wich streamlined data recall
Interlaboratory Quality Assurance Program (IQAP) complements your lab's in-house quality control efforts and increases confidence in your results
Downloadable IQAP data and uploadable control assay reduce manual data manipulation and saue time
Qualitative flagging Speeds review of patient results and decreases turnaround time
20 user-definable patient and action ranges for increased flexibility
Individual log books consolidate and automate record keeping
Easy to Operate
Integrated autoloader processes 1 to 100 samples, loading up to ten racks (each holding ten 13 x 75 mm tubes) for higher testing capacity 80 samples per hour
Two additional tube holders accommodate tubes of varying sizes, such as pediatric tubes, for increased system flexibility during Manual mode sampling
Internat point-of-aspiration barcode reader provides positive sample identification
STAT interrupt, enables operators to bypass the autoloader and load an emergency sample for prioritized testing
System recognizes whole blond vs. platelet concentrate and automatically applies the appropriate linearity and reportable rangen
Comprehensive on-board Help database uses key Word searches to help solve problems quickly and easily
CD-ROM Help software demonstrates system Operation and troubleshooting, thus speedirig training for new operators
An external Computer wich Windows NT software enables easy Operator Management
Intuitive icons make the system easy to operate and streamline testing workflow
Specifications
Method and Technologien
Sequential dilution System
Dual focused flow fluid dynamics
CBC Analysis and Hgb
§ Coulter Principle (impedance): counting and sizing
§ Duplicate counting
§ Coincidence correction
§ Pulse editing
§ Rinse flow system
§ Spectrophotometry for hemoglobin
§ Beckman Coulter AcT 5diff reagent system
5-Part Differential Analysis
§ Absorbance Cytochemistry with Volume
§ AcT 5diff Fix and WBC Lyse system
Available Parameters
WBC RBC PLT
NE# Hgb MPV
NE% HCT PCT*
LY# MCV PDW*
LY% MCH
MO# MCHC
MO% RDW
EO#
EO%
BA#
BA%
ATL#*
ATL%*
IMM#*
IMM%*
*For research use only.
Optional parameters availabie outside US.
Sample Handling
§ 53 µL whole blood, CBC/DIFF Mode
§ 30 µL whole blood, CBC Only Mode
§ Universal closed tube sampling system
Quality Control
§ AcT 5diff Control Plus (tri-level/barcoded)
§ AcT 5diff Cal (Calibrator)
Precision
Parameter CV
WBC <2% at 10 x 10 3 cells/µL
RBC <2% at 5 x 10 6 cells/µL
Hgb <1% at 15 g/dL
HCT <2% at 45%
PLT <5% at 300 x 10 3 cells/µL
Accuracy
Correlation r >0.95 for WBC, RBC, PLT, Hgb, Hct
Positive ID
§ Internat barcode reader
§ Hand-held barcode reader
§ Codabar
§ Code 39
§ Code 128
§ Interleaved 2-of-5
§ EAN 8
§ EAN 13
AcT 5diff AL Operating Range
Parameter Range Units
WBC 0-150 10 3 /µL
RBC 0-18 10 6 /µL
PLT 0-1900 10 3 /µL
PLT Concentrate 0-2800 10 3 /µL
HCT 0-80
Hgb 0-30 g/dL
Linearity
WBC 0.4-120.0 x 10 3 /µL
RBC 0.3-8.0 x 10 6 /µL
Hgb 1.3-24.0 g/dL
HCT 2-67.0%
PLT 10-1000 x 10 3 /µL
PLT Concentrate 100-1900 x 10 3 /µL
Dimensions/Weight
Height 21.5" (54.21 cm)
Width 32.3" (81.45 cm)
Depth 22.5" (57.73 cm)
Weight 121.3 lbs (55 kg)
Throughput
Up to 80 samples/hour
Data Management
§ Auto-sequence run number available
§ 20 flagging Set (8 are predefined, 12 can be added)
§ 20 result action rangen with interpretive messages
§ Customizable report format
§ 5 reporting unit format options
§ RS232C holt transmission (multiple formats)
§ 10,000 patient result storage
§ On board quality control (24 control fites)
§ Worklist capability for addition of patient demographics
§ On board help fites
§ Control data upload
§ Calibration data upload
§ IQAP download
Sample Stability
§ CBC 48 hr room temperature
§ DIFF 24 hr room temperature
Operating Temperature
16 to 34°C (61 to 93°F)