Archivio

Clean Air Laminarflow

Seriennummer: 014086
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00014086
Seriennummer 014086
Nome oggetto Clean Air Laminarflow
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   Clean Air

Modell:                Laminarflow

Kommentar:        Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

The cabinets offer the highest product protection. The vertical or horizontal Class 100 airflow prevents contaminated outside air to enter the workstation's work area, ensuring product protection.

Its application is in the field of pharmaceutical industry, biotechnology, pharmacies, hospital and university laboratories as well as tissue culture and electronic laboratories.

The DLF is a high-quality product constructed with high-grade components and materials, with new techniques, such as:

n          Microprocessor control with a LCD display for the Interface with the user;

n          Automatic up speeding fan; when there is increasing resistance in the filter the necessary airspeeds are maintained;

n          Window construction that can be operated manually;

n          User friendly window construction with a hinge mechanism easy to operate.


Partlist:

1 Pre-filter

2 Fan

3 Plenum-construction

4 Front panel

5 Downflow HEPA-filter

6 Lighting

7 Hinge/slide window

8 Plenum-construction

9 Worktop


Type plate

On type plate (right upper side) there are instructions that are important for the connection of the cabinet.

Hinge-slidewindow (option)

The hinge-slide window is a tightly closing, manually operated glass or acryl window. It can be slide up or down, and open and close it by means of handgrips.

Top panel

In and behind the top panel a number of electrical components are mounted.

n          Operating panel / operating board

n          Interface board, including engine control

To check one of these components, you need to remove the pre-filter.

Worktop

The workroom contains a stainless steel (SS 304) worktop.

Plenum-construction

The plenum-construction equalizes the air trough the downflow filter.

Downflow filter

The downflow HEPA-filter* has a very high efficiency: Class H14 in accordance with EN1822. After mounting, each filter will be separately tested according to EN 12469, Annex D. Through the service panel the downflow filter can be reached.

*) High Efficiency Particulate Air filter

Pre-filter

The pre-filter is a filter in the class G4 accordance with EN779. Furthermore the pre-filter will enhance the life span of the HEPA-filter significantly.

Support frame / foot support (optional)

For a stable positioning of the cabinet we recommend the use of a support frame. For a good ergonomic work position the use of a in steps adjustable foot support is recommended. In addition, it is recommended to use an in height adjustable, well disinfectable, chair to optimize the work position. As well, the foot support will increase the rigidity of the cabinet.

Main power connection

The main power connection is positioned an the top of the cabinet. The power Gable length is maximum 3 meters and should always be accessible. See technical specifications for details.

Electronics

The electronics consists of:

n          Operational print; positioned in the top panel behind the operating panel;

n          Control print including:

•            Fuse folders (see Technical specifications for fuse-numbers)

•            Fan control

The control is free adjustable in the range between 0 % and 100 %

Air velocity compensating microprocessor regulates fanspeed to compensate for main power fluctuations and filter pollution.

•            Independent potential free Output contact.

Operating panel

The operating panel consist of:

1- Display;

2- Fundion keys (4x);

3- Fixed keys (4x);

4- Signals.

Display:

The display has 4 lines, the lowest line gives the description of the key underneath.

Fixed keys:

Function keys:

The function of keys 1,2,3 and 4 are variable. In the last line of the display the function is showed.

Signals:

TL-lighting

The TL-Lighting is mounted in the Light unit.

Fan

The electric driven double suction fan is maintenance-free.

UV-Radiator

The UV radiator is meant for disinfecting the working surface of the safety cabinet.

When the UV-radiator is on, the TL lighting will be switched off. The UV radiator can only be switched on when the window is closed, this makes sure the user will not get in contact with UV-C radiation.

The UV switch-function is only visible when the window is closed.

The UV light is be switched on through the display. It is also possible to adjust the UV disinfecting, for each day a certain disinfecting period can be defined.

When the UV is switched on, the UV hour Counter counts the lighting period. UV-Iamps haue, dependable from fabricate and type, a limit in effective running hours. Replace the lamp frequently.

Sockets

The sockets are mounted on the back wall of the working area.

They can be operated at the control panel. See "General specifications" for electrical details.

Technical specifications

Physical Surrounding

DLF 360

DLF 460

DLF 560

DLF 660

Transport physics

Surrounding temperature

[°C]

-25-55

-25-55

-25-55

-25-55

Surrounding temperature

(max 24 [h])

[°C]

-25-75

-25-75

-25-75

-25-75

Humidity

[%]

20-90

20-90

20-90

20-90

In use physics

Surrounding temperature

[°C]

15-30

15-30

15-30

15-30

Surrounding temperature

(max 24 [h])

[°C]

15-75

15-30

15-30

15-30

Humidity

[%]

30-80

30-80

30-80

30-80

General specifications

DLF 360

DLF 460

DLF 560

DLF 660

 

Dimensions

 

Front aperture height

[mm]

165

165

165

165

 

Outer meas. (Excluding Support

frame (bxdxh)

[mm]

985x740x1360

1290x740x1360

1595x740x1360

1900x740x1360

 

Height including. Support frame

[mm]

2240

2240

2240

2240

 

900 [mm]

 

Working area (bxdxh)

[mm]

885x600x685

1190x600x685

1495x600x685

1800x600x685

 

Sound level

(according ISO 11201)

[dBA]

58

58

58

58

 

Mass

[kg]

150

200

250

300

 

Air-flow

[m 3 /h]

680

900

1150

1360

 

 

Electrics

 

Power connection

[V]

230

230

230

230

 

[Hz]

50

50

50

50

 

Needed current security

[A]

16

16

16

16

 

J6: Alarm, potential-free contact

[V / [A]

48/1

48/1

48/1

48/1

 

Sockets

Umax.

230/ 5

230/ 5

230/5

230/ 5

 

[V] / I

 

Nom. Power (std)

Pnom.

400

400

400

400

 

[W]

 

Maximum Power (std)

Pmax.

700

700

700

700

 

[W]

 

Maximum Power Socket

Pmax.

1150

1150

1150

1150

 

[W]

 

Maximum Power with socket

Pmax.

1850

1850

1850

1850

 

(std)

[W]

 

Nominale current (std)

Inom. [A]

1.7

1.7

1.7

1.7

 

Maximum current (std)

Imax. [A]

3.0

3.0

3.0

3.0

 

Maximum current with socket

(std)

Imax. [A]

8.0

8.0

8.0

8.0

 

Control

Automatic

Automatic

Automatic

Automatic

Software version

1.0

1.0

1.0

1.0

Lighting

TL-High Output

lx

lx

lx

lx

Color

White — Nr.840

White — Nr.840

White — Nr.840

White — Nr.840

Diameter

026 [mm]

026 [mm]

026 [mm]

026 [mm]

Power

[W]

18

36

36

58

Intensity (mean)

[Lux]

> 800

> 800

> 800

> 800

Fuses

F1: PCB; 24 [V]

[A]

0.5

0.5

0.5

0.5

F3: Lighting

[A]

0.5

0.5

0.5

0.5

F4: UV-radiator

[A]

0.5

0.5

0.5

0.5

F5: Socket 2

[A]

3,15

3,15

3,15

3,15

F6: Socket 1

[A]

3,15

3,15

3,15

3,15

F7: Fan

[A]

8

8

8

8

F8: PCB

[A]

1.4

1.4

1.4

1.4

F9: PCB

[A]

1.4

1.4

1.4

1.4

Options:

UV-radiato r

Type

uv-c

uv-c

uv-c

uv-c

Power

[W]

30

30

30

30

Current

[nm]

253

253

253

253

Gruppo prodotti: Cappe a Flusso Laminare

Non è stato trovato alcun prodotto corrispondente alla selezione.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure