GC / MS

Agilent 7890 A GCMS

40.778,00 €
Excl. 19% VAT , excl. Shipping Cost
48.525,82 € incl. Vat
Seriennummer: 38007
Stato: Stock unit?The device is in our stock, however, has to be inspected by our technician, in order to be able to guarantee complete function.
Spedizione: 3-4 weeks
Descrizione:
Agilent GCMS 7890A / 220 EI. Consiste in:
Agilent Gascromatografo 7890A.
Agilent Spettrometro di massa 220 EI Trappola ionica.
Gerstel Autocampionatore MPS.
Agilent Pompa per vuoto DS 42 con scatola insonorizzata.
Pacchetto software.
230 V. 50/60 Hz. 2950 W.
Installation
Eseguiamo l'installazione di questo dispositivo di laboratorio in modo professionale. Saremo lieti di offrirvi l'installazione di questo dispositivo di laboratorio per 2980€, escluse le spese di viaggio.

Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.


We would be pleased to take over the professional installation of your laboratory devices!

Please contact us.


Benefit from the installation by us in more than one way:

  • Immediate and smooth startup of your laboratory device
  • A professional installation extends the lifetime of your laboratory device
  • Guarantee extends to 3 months
  • Freight charges do not apply*
  • You are entitled to benefit from the Labexchange Repurchase Guarantee.

* products of the product groups laboratory furniture and laminar flow are excluded. In individual cases, other product groups can be excluded.


Add to Offer list
Maggiori Informazioni
Objektnummer B00038007
Seriennummer 38007
Nome oggetto Agilent 7890 A GCMS
Stato Lagergerät
Fabbricante Agilent
Spedizione 3-4 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Company:   Agilent

Model:         7890A

 

 

The following illustrations and descriptions are model-based and drawn from brochures.

Do not give the delivery volume again.

The exact delivery content you will find only in the offering text.

 

 

 

For Agilent characteristic performance and reliability

The electronic pneumatics control (EPC) of the fifth generation, and digital electronics set a new benchmark for the precision of Retention Time Locking (RTL) and make the 7890A Agilent's most dependable GC ever.

 

 

High efficiency

Faster oven cool down, robust backflush capability, advanced automation features and faster GC / MS oven ramps can ma n more done in less time. At the lowest cost per sample everything is integrated into your existing methods.

 

 

Advanced Chromatographiemöglichkeiten

Highly flexible EPC design enables even larger number of sophisticated hydrocarbon analyzes. An optional third detector (TCD) can speed up complex gas analyzes and allows more types of analyzes to be run on a single GC.

 

 

Easier to use

The powerful, user-friendly software simplifies method development and system operation and minimizes training time. Practical, time-saving design features speed up and simplify routine maintenance.

 

 

QuickSwap

By using an inexpensive QuickSwap coupling can be the column within 30 seconds without venting and without losing vacuum safely solve

 

 

Deans Switch

Deans circuits enable two-dimensional GC (Heart Cutting) for analysis of trace constituents in complex samples.

 

 

Flow Splitting

By sending a sample to multiple detectors can receive comprehensive information samples in one run. This is especially valuable if you want to analyze components in complex matrices. This technique can help to capture interesting peaks faster to integrate target peaks better and to have a higher confidence in the identification of unknown substances.

 

 

Backflushing

Backflushing is a very valuable technique that can be implemented in any flushed Agilent Capillary Flow System. This can improve the quality of the analysis and save time and money on every run. Since BackFlush takes place after the run,

you do not change the method parameters for the chromatographic run.

By reversing column flow immediately after the last interesting component is eluted, you can avoid long bakeout for strongly retained sample components. Instead, these components are pressed backwards through the column and vented through the split vent. Disappearances, contamination, retention time shifts and contamination of the ion source can be prevented in this way

 

 

The GC software, perfect for your workflow and your applications

The Agilent GC software makes it even for non-experienced users easy to take advantage of the advanced capabilities of the Agilent 7890A system: from user-friendly and familiar GC and GC / MSD ChemStation and EZChrom Elite chromatography data systems to our fundamentally new Lab Monitor & Diagnostic Software. Everything is designed so that you can make the most of every run and every workday.

If you work in a regulated environment, Agilent software can with comprehensive functions also help to comply with the strict legal, certification and quality assurance provisions of the industry

 

 

The 7890A GC is supported by all your data systems.

Regardless of whether one the GC ChemStation, which uses GC / MSD ChemStation, EZChrom Elite or the enterprise-wide Agilent OL system, you can be sure that all support the 7890A GC. As with the earlier 6890 hardware platform provides each of the systems the same simple method development for the 7890A and the full functionality of the Lab Monitor & Diagnostic Software, and also a performance improvement with overlapping ALS and BackFlush.

 

 

Another detector, another place and another user - the results are the same, however.

The Retention Time Locking (RTL) software is a powerful tool that makes it possible to reproduce the same results on multiple Agilent GC or GC / MSD systems - and this configuration to configuration, from place to place and from user to user , This breakthrough technology from Agilent makes it possible to reproduce retention times within hundredth Lund even thousands of minutes. RTL enables easy and accurately identify peaks, increase sample throughput, reduce the risk of non-compliance, to promote confidence in the analytical results, and also reduce operating costs

 

 

The Lab Monitor & Diagnostic Software maximizes uptime by identifying problems before they occur

The innovative Agilent Lab Monitor & Diagnostic software monitors a single or multiple Agilent GC or GC / MSD systems in real time, to draw attention to GC maintenance or equipment problems before they deteriorate your results.

The software also monitors the number of injections, the uptime and user-defined parameters. Lets you know when to switch Consumables

must be, or performs basic measures for servicing via pop-up, telephone or e-mail from. She performs a quick and easy to set up diagnostic routine to ensure proper instrument performance.

The modular, fully automated Agilent 7890A GC system includes the largest in the industry selection of inlets, detectors, columns, consumables and sample introduction options - in fact everything you need to obtain a laboratory to date and the peak performance upright.

 

 

FID with full dynamic range

A hyper modern electrometer enables a linear dynamic range of 107, which is seamlessly integrated into a single run.

 

 

Sensitive and selective detection elements

Agilent offers a wide variety of element sensitive detectors, including a flame photometric detector (FPD), which was recently optimized and has a 5-fold sensitivity of sulfur and a 10- to 15-fold sensitivity to phosphorus. The sulfur Chemoluminiszenzdetektor (SCD) provides the highest sensitivity and selectivity for complex applications.

 

 

Perfect, efficient partner for the 7890A GC

The Agilent 7683 Automatic Liquid Sampler offers the fastest injection times of any GC autosampler ever, greater solvent capacity, optional multiple injections, dual simultaneous injection and more. The 7683 ALS - the optimal support.

 

 

Best ECD productivity

The Agilent electron capture detector (ECD) combines excellent sensitivity and linearity with ruggedness and reliability. One no longer needs to concentrate highly diluted samples and not dilute concentrated samples to remain in the calibration range.

 

 

Agilent G1888 headspace sampler for advanced analysis

Automatic task of volatiles from virtually any sample matrix directly into a GC or GC / MS. An inert sample line provides superior chemical performance without analyte degradation or loss.

  

 

Increasing the capacity of laboratories with automatic ized sample preparation

The diverse CombiPAL autosampler for liquid injection, headspace and solid phase micro extraction (SPME). The cost GC PAL platform can be assembled for liquid injection only, but offers many other ways of CombiPAL including large volume injection (LVI), multiple sample bottles sizes and extended sample vial capacity.

 

 

Agilent J & W High performance columns and supplies for each analytical requirement

The Agilent GC consumables with J & WSäulen has been designed, manufactured and packed in such a maximum guarantees of performance with the Agilent GC and GC / MSD system. It seeks to provide the cleanest, most inert flow path possible. From own deactivated inlet liners on the J & W low bleed columns to injection-molded gold seals samples are protected from exposure to active sites or out-gassed foreign materials which might otherwise affect the results.

 

 

Comprehensive selection of inlets to optimize your separations

  • Split / splitless (SSL) capillary
  • Purged packed column inlet (PPIP)
  • Cool on-column (COC)
  • Cool on-column with solvent vapor exit (COC SVE)
  • Programmable temperature vaporization (PTV)
  • Volatiles interface (VI)
  • High temperature PTV High pressure gas sample injection
  • LPG directly
  • Programmable Temperature precolumn

 

 

High-sensitivity detectors for every sample type

  • Mass selective (Agilent 5975 Series MSD)
  • Flame ionization detector (FID)
  • Thermal Conductivity (TCD)
  • Micro-electron capture (micro-ECD)
  • Flame Photometric, single or dual wavelength (FPD)
  • Nitrogen-Phosphorus (NPD)
  • Sulfur Chemoluminisizenz (SCD)
  • Nitrogen Chemoluminiscenz (NCD)
  • Atomic emission (AED)
  • Pulsed Flame photometric (PFPD)
  • Photoionization (PID)
  • Electrical conductivity (ELCD)
  • Discharge ionization (DID)

Gruppo prodotti: GCMS

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure