CBS V-1500
Objektnummer | B00014671 |
---|---|
Seriennummer | 014671 |
Nome oggetto | CBS V-1500 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: CBS
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
The V Series or Isothermal Storage Units are designed to maintain liquid nitrogen levels vvithin specified parameters inside the walls of a cryogenic storage vessel.This is achieved by measuring gravitational weight of the liquid nitrogen with a pressure sensing unit in the controller. The controller activates the FILL solenoid valve when the liquid level goes below the LOW level setpoint, and deactivates the solenoid valve, stopping the fill, when the level reaches the HIGH setpoint.
Units equipped with the Bypass Option haue an additional solenoid valve to vent vapor or gas from the transfer lines before the FILL solenoid is activated. In the description below, the part of the sequence which is unique to the Bypass Option is in [brackets]. All other information refers to units with or without the Bypass Option.
During regular operation, the sequence of events is as follows: When liquid level in the vessel falls below the low level setpoint, a signal is sent to the controller. At this time the FILL solenoid valve is activated, allowing the flow of liquid into the vessel. [The Bypass Option will activate the VENT solenoid firnt to release gas or vapor from the transfer lines. The venting will continue until the line temperature reaches approximately -130° to -140° C. This can be adjusted, consult the factory for more information. When the line reaches this temperature the vessel will begin to fill.] When the liquid level reaches the high level setpoint a signal is sent to the controller which deactivates the solenoid valve and Stops the flow of liquid into the vessel. As long as the unit is powered up, this fill sequence repeats as necessary; maintaining the desired liquid level.
Check unit daily to ensure proper operation and safety of the stored Samples. For the V Series units it is essential to lift the lid each day and check for vapor and signs of proper freezing.
Storage Unit Parameters
Cooling Medium : Liquid nitrogen only (supplied by a pressurized cryogenic transport vessel)
Operating Pressure : 22 p.s.i.
IMPORTANT : Operating pressure 22 p.s.i. max/18 p.s.i. min. If the pressure is greater or less, the efficiency of your liquid nitrogen storage unit will be adversely affected.
Power Supply Voltage : 120 Volts AC 60 Hz Standard - 220 Volts AC 60/50 Hz optional Amperage : 1 amp max
Fuse : 1 amp Slow Blow - 220 Volts AC (automotive glass tube type fuse)
Operating levels for LN 2 : 0 to 28 Inches (higher fill heights may be used, call factory for further info)
Specifications: V1500
Liquid Nitrogen Capacity (liters): 30
Static Evaporation Rate (liters/day): 5
Static Holding Time (days): 6
External Dimensions (inches/cm):
Width: 26/660
Depth: 37/939
Height: 45/1143
Usable Interior Height (inches/cm): 29/736
Usable Interior Diameter (inches/cm): 21/534
Weight Empty (lbs/kg): 327/148
Weight Full (lbs/kg): 383/174