Büchi NIRFlex N-400
| Objektnummer | B00021881 |
|---|---|
| Seriennummer | 021881 |
| Nome oggetto | Büchi NIRFlex N-400 |
| Stato | Archived Product |
Gruppo prodotti: Spettrometri NIR
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Büchi
Modell: NIRFlex N-400
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Technische Daten
Wellenzahl (cm') Wellenlänge (nm)
Messprinzip
Gemessener Bereich 4000 - 10000 1000 - 2500
Empfohlener Bereich:
Externe Messoption (Sonden) 4500 - 10000 1000 - 2220
Externe Messoption (Probentisch) 4300 - 10000 1000 - 2330
Transmission via Glas-Küvetten (Küvettenschacht) 4000 - 10000 1000 - 2500
Wellenzahlengenauigkeit abs. ± 2 * ± 0.20 (bei 1'000), ± 1.20 (bei 2'500)
Wellenzahlenwiederholbarkeit rel. ± 0,5 * ± 0.05 (bei 1'000), ± 0.3 (bei 2'500)
Geräteauflösung
ohne Apodisation 12 über den ganzen Bereich 1.2 (bei 1'000), 8.0 (bei 2'500)
mit Apodisation 25 über den ganzen Bereich 2.5 (bei 1'000), 16.0 (bei 2'500)
Photometrische Dynamik 0 — 2 AU**
Photometrisches Rauschen 1 Promille bei 0 AU (beim Intensitätsmaximum)***
*gültig für gemessene Wellenzahlen im Bereich 5500-10000
**AU= Absorbance Unit, negativer Logarithmus der transmittierten oder reflektierten Intensität
***Sigma-Werte der Gauss'schen Verteilung bei der Scanzahl 1, aufgenommen durch den Lichtleiter.
Detektor PbS (thermostatisiert)
Messzeit/Scan ca 4 sec.
Schnittstelle RS-232
Netzanschluss 230 V, 50/60 Hz, 90 VA bzw. 115 V, 50/60 Hz, 90 VA bzw. 100 V, 50/60 Hz, 90 VA
Abmessungen B 505 mm, T 505 mm, H 210 mm
Gewicht 34.5 kg
Aufwärmzeit Bei einer Raumtemperatur von 20 bis 25°C etwa 10 Minuten. Je nach Aufgabenstellung empfiehlt sich eine längere Aufwärmzeit.
Umgebungsbedingungen max. 5°C - 35°C, nicht kondensierend, empfohlen 15°C - 30°C, nicht kondensierend
Verschmutzungsgrad 2
Überspannungskategorie II
Betriebshöhe max. 4000 m
Umgebungsfeuchtigkeit 75% RH bei 35°C
Elektrische Versorgung 100 / 115 / 230 V; 90 VA
Verwendete Materialien:
|
Bezeichnung |
Materialien |
|
Aussengehäuse Innengehäuse Grundplatte Quarzkeil Polarisatoren Kühlelement |
Aluminium Stahlblech Aluminium SiO2 Kalkspat (CaCO3) Kupfer |