Brookfield LVT
| Objektnummer | B00001924 |
|---|---|
| Seriennummer | 001924 |
| Nome oggetto | Brookfield LVT |
| Stato | Archived Product |
Gruppo prodotti: Viscosimetri
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Brookfield
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.
Principle of Operation
The Brookfield Digital Viscometer rotates a sensing element in a fluid and measures the torque necessary to overcome the viscous resistance to the induced movement. This is accomplished by driving the immersed element, which is called a spindle, through a beryllium copper spring. The degree to which the spring is wound, detected by a rotational transducer, is proportional to the viscosity of the fluid.
Continuous readout of viscosity can be accomplished in two ways: by means of the integral three-digit LED display, or by the 0-10 mv analog output signal which can be fed into a variety of indicating or recording devices.
The Viscometer is able to measure over a number of ranges since, for a given spring deflection, the actual viscosity is proportional to the spindle speed and is related to the spindle's size and shape. For a material of given viscosity, the drag will be greater as the spindle size and/or rotational speed increase. The minimum viscosity. range is obtained by using the langest spindle at the highest speed; the maximum range by using the smallest spindle at the slowest speed.
Measurements mode using the saure spindle at different speeds are used to detect and evaluate the rheological properties of the test material. Our booklet, "Solutions to Sticky Problems" discusses the Viscometer's use in this respect.
Introduction
The Digital Viscometer is powered by a precision synchronous motor. Exact speeds of rotation are assured as the motor will turn erratically and spasmodically if synchronism cannot be maintained.
Speed changes are effected by a transmission having eight speeds. The square speed control knob has two numbers on each face; by moving the knob through two complete turns the eight speeds may be selected in sequence. No trouble will be experienced in differentiating between the two speeds shown on each face, since each pair is in the ratio of 20:1.
To ensure rotation at the indicated speed it is important that the face of the knob upon which this speed is shown be closely parallel to the Viscometer's base. Although not absolutely necessary, it is advisable to change speeds while the motor is running.
LV Viscometers are provided with a set of four spindles and a narrow guard leg; RV Viscometers come with a set of seven spindles and a wider guard leg; HA and HB Viscometers come with a set of seven spindles and no guard leg.
The spindles are attached to the Viscometer by screwing them to the Iower shaft. Note that the spindles have a left-hand thread. The Iower shaft should be held in one hand and the spindle screwed to the left. The face of the spindle nut and the matching surface on the Iower shaft should be smooth and clean to prevent eccentric rotation of the spindle.
|
SPEED (RPM) |
LV SERIES VISCOMETERS |
5 X LV SERIES VISCOMETERS |
|
||||||||
|
SPINDLE NUMBER |
SPINDLE NUMBER |
|
|||||||||
|
18 |
31 |
34 |
16 |
25 |
18 |
31 |
34 |
16 |
25 |
||
|
60 |
0.5 |
5 |
10 |
20 |
80 |
||||||
|
2.5 |
25 |
50 |
100 |
400 |
|
||||||
|
30 |
1 |
10 |
20 |
40 |
160 |
5 |
50 |
100 |
200 |
800 |
|
|
12 |
2.5 |
25 |
50 |
100 |
400 |
12.5 |
125 |
250 |
500 |
2M |
|
|
6 |
5 |
50 |
100 |
200 |
800 |
25 |
250 |
500 |
1M |
4M |
|
|
3 |
10 |
100 |
200 |
400 |
1.6M |
50 |
500 |
1M |
2M |
8M |
|
|
1.5 |
20 |
200 |
400 |
800 |
3.2M |
100 |
1M |
2M |
4M |
16M |
|
|
0.6 |
50 |
500 |
1M |
2M |
8M |
250 |
2.5M |
5M |
10M |
40M |
|
|
0.3 |
100 |
1M |
2M |
4M |
16M |
500 |
5M |
10M |
20M |
80M |
|
|
SPINDLE AND CHAMBER |
VISCOSITY RANGE (CPS) |
SHEAR RATE (SEC -1 ) |
SAMPLE VOLUME (cc) |
||
|
LVT |
LVF |
5XLVT |
|||
|
SC4-18/13 |
5-10,000 |
5-500 |
25-50,000 |
1.32N |
8.0 |
|
SC4-31/13 |
50-100,000 |
50-5,000 |
250-500,000 |
0.34N |
10.0 |
|
SC4-34/13 |
100-200,000 |
100-10,000 |
500-1,000,000 |
0.28N |
10.0 |
|
SC4-16/8 |
200-400,000 |
200-20,000 |
1,000-2,000,000 |
0.29N |
4.2 |
|
SC4-25/13 |
800-1,600,000 |
800-80,000 |
4,000-8,000,000 |
0.22N |
16.0 |