Bioscience Konelab 20i

Seriennummer: 014463
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Bioscience clinica analizzatore chimico Konelab 20i. Ricostruita.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00014463
Seriennummer 014463
Nome oggetto Bioscience Konelab 20i
Stato Archived Product

Gruppo prodotti: Chimica Clinica

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

 

Firma:            Thermo Scientific

Modell:           Konelab 20

 

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 


Technische Daten:

Testdurchsatz

Auslastungsabhängig; typischer Normalbetrieb bis zu 200 Tests/ Stunde. Zeit bis zum ersten Ergebnis typischerweise 3 bis 12 Minuten.

 

Proben

Ständiger Zugriff auf die Proben ohne Unterbrechung des Analysenbetriebs möglich.

Max. Ladekapazität:

84 Routine- und 5 Notfallproben in 6 Segmenten à 14 Positionen pro Segment. Mit Barcode-Leser und Gefäßtyperkennung.

Probencups à 0,5 und 2,0 ml, Röhrchen à 5 und 7 ml, Röhrchen à 10 ml mit passenden Segmenten.

Probenarten: Serum, Plasma, Urin, Liquor.

Probenvolumina: Zulässig 1-120 µl ; typisch 2-15 µl und 50 µl für Na+, K+ und CI--ISE-Tests.

 

Reagenzien

Ständiger Zugriff auf die Reagenzien ohne Unterbrechung des Analysen­betriebs möglich. Erkennung durch externen Barcode-Leser. Reagenzsta­tus wird in Echtzeit deutlich angezeigt. Bis zu vier Pipettierschritte pro Test möglich.

Lagerung im System:

35 Positionen im gekühlten Reagenzteller.

Reagenzgefäße: 10, 20 und 60 ml

Reagenzvolumina: 2-250 µl; typi­scherweise 120-200 µl.

 

Küvetten

Diskrete Einweg-Multizellküvette mit 12 Zellen. Ständiger Zugriff auf die Küvetten ohne Unterbrechung des Analysenbetriebs möglich.

Ladekapazität:

600 Messzellen in 50 Multizellküvet­ten à 12 Reaktionszellen; typische Walk-away-Zeit bis zu 3 Stunden.

 

Kalibration

Linear, nichtlinear oder Leerwert­kalibration. Je nach Testverfahren entweder Einsatz eines Einzelkali­brators oder automatische Verdün­nungsreihe eines Primärstandards. Automatische Wiederholung für Leerwertkorrektur möglich.

 

Qualitätskontrolle

Echtzeit-Qualitätskontrolle nach verschiedenen benutzerdefinier­baren Westgard-Regeln. Program­mierbare Kontrollintervalle. Grafische Aufbereitung und Aus­druck von QK-Daten, Tages- und kumulative Berichte.

 

Pipettieren von Proben und Reagenzien

Einzel-Nadel-Prinzip mit Durch­flussspülung, äußerlicher Reinigung und Flüssigkeitssensoren. Pipettierung mit Präzisionsspritzen, Antrieb durch Mikroschrittmotor.

Endvolumina:                             100-250 µl.

Reproduzierbarkeit                    VK unter 2 % bei

Probenvolumen                         >2 µl und Reagenzvolumen >5 µl

 

Photometrische Messung

Ein-Kanal-Filterphotometer mit Strahlsplitterreferenz. -11 feste Filter, weitere auf Anfrage erhältich.

Spektralbereich:            340-800 nm.

Messtemperatur:           37 °C.

Messprinzipien:             Kolorimetrie, Turbidimetrie.

Messarten:                    kinetisch, Endpunkt.

kinetische Messungen: 30 sek-60 min, max. 12 Punkte.

Lichtquelle:                   Halogenlampe mit linearem Absorptionsbereich von 0-2,5 A, Auflösung von 0,001 A und Reproduzierbarkeit von                SD<0,005 E bei 2 E.

 