BioRad Spot Cutter
| Objektnummer | B00010245 |
|---|---|
| Seriennummer | 010245 |
| Nome oggetto | BioRad Spot Cutter |
| Stato | Archived Product |
Gruppo prodotti: Life Science / Biotecnologie
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Fig. 2. The ProteomeWorks Spot Cutter.
General Description
The ProteomeWorks Spot Cutter System is a precision instrument for the accurate location, excision and loading into microtiter plates (MTP) of protein spots after separation on 2-D electrophoresis gels or PVDF membranes. The system has been designed to be both robust in construction and simple to operate.
System Description
The Spot Cutter
Bench footprint of 50 x 50 cm with a curving camera support arm holding a camera over the platform of the work surface. Under platform lights used for gel imaging, an x,y arm supporting the cutting head mechanism, the gel or PVDF cutting area, a microtiter plate holding area, wash well area containing 4 wash tubes.
The Camera
Cooled CCD camera, 1392x1040 imaging pixels, 12 bit ADC
Working Surface
The working surface is shown in Appendix B and consists of two main areas, the cutting surface and the microtiter plate holder / wash wells area. In addition there is also a bubble level which is used to ensure the cutting surface is level.
Cutting Surface
The cutting platform dimensions are 25 x 25 cm. The cutting tip can access an area of 22 cm x 20.5 cm within this 25 x 25 cm area. The cutting tip range will cover the protein resolving area of any commercially available gel type. The extra platform area was designed to accommodate the entire gel without the need for cutting the gel to fit the cutting platform. The diagram below shown the orientation of the cutting area within the platform. Gels should be positioned against the right wall of the cutting platform, next to the microtiter plate holder, and centered vertically in the platform.
Cutting Mats
Two cutting mats are provided with the system. The cutting mats provide for a flexible surface beneath the gel to allow for complete excision of the gel spots. The mats may become scored by the cutting tip, stained by the gel stains, or become cracked with repeated use over time.
Gel Cutting Sheets
Gel Cutting Sheets are thin plastic sheets that are positioned between the cutting mat and the gel in the cutting area. This prevents scoring by the cutting tip and extends the life of the cutting mat. The Gel Cutting Sheets can also be used to Lift gels out of storage trays to minimize damage to gels from excessive handling.
Gel-holding bars
Two custom designed stainless steel Gel-holding Bars are included in the accessory box with the Spot cutter. These gel holding bars are used to immobilize the Coomassie stained PVDF membrane during the X, Y calibration procedure, as well as for general gel excision processing. While the cutting tip does not impart any orthogonal forte to the gel, correct placement of these Gel-holding bars on the gel prevents any gel movement during the gel excision process.
Position the bars resting on the outer edge of the gel or membrane, It is best to position them to the left side and bottom of the gel so they are out of the cutting tip travel path.