Soldé

BioRad Gene Pulser II

Seriennummer: 008873
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
BioRad sistema Gene Pulser II Electoporation Con Gene Pulser Controller.Baujahr: 1998. Prezzo originale: 4.663, - € ..
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00008873
Seriennummer 008873
Nome oggetto BioRad Gene Pulser II
Stato Archived Product

Gruppo prodotti: Life Science / Biotecnologie

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              BioRad

Modell:            Gene Pulser II

Kommentar:   Dokumente engl.

Gene Pulser II System Description

The new Gene Pulser II system is a completely redesigned electroporation system, which offers improved performance, flexibility, sample protection, and safety. The Gene Pulser II system uses the Pulse Trac waveform delivery system to generate the most accurate exponential decay pulses possible for optimal cell transformation within an electroporation cuvette. The Pulse Trac delivery system accurately calculates the time constant of each pulse based on what is actually delivered to the sample.

The revolutionary Pulse Trac waveform delivery system provides:

• Sample conductivity measurement integrated wich pulse output for true waveform delivery regardless of sample

• Internal calibration and circuit monitoring program for accurate pulse delivery throughout the lifetime of the unit

• Improved time constant accuracy

Other features of the new Gene Pulser II system include:

• Error free assembly, since each module uses unique cable connectors, keyed to fit only in the proper orientation and location

• Automatic display of time constant after every pulse, to make it easier to record this essen­tial pulse parameter

• Easier optimization of novel prokaryotic applications wich a wider range of high voltage capacitors (1.0, 3.0, 10, 25, and 50 µF) in the Gene Pulser II unit

• Pinpointing of optimal field strengths, with voltage selection in 2 V increments for mam­malian cell electroporation (low voltage/high capacitance) and operation at a higher maximum voltage (up to 500 V). In addition, voltage selection in 10 V increments for bacterial (high volt­age/low capacitance) electroporation

• Increased control of high voltage pulses used for bacteria and yeast electro-transformation wich the five new resistors in the Pulse Controller PLUS module

• Expanded range of precision capacitors for reproducible mammalian cell electroporation; 25 µF-3,275 µF with the Capacitance Extender PLUS module or 25 µF-1,075 µF with the Capacitance Extender II module. This permits greater time constant reproducibility and flexibility with electronically calibrated capacitors in 25 µF increments. At any time, the Pulse Trac circuitry can verify and calibrate these capacitors within ±10% variation for the ulti­mate in pulse reproducibility and precision.

• Designed and certified to meet IEC 1010 safety standards

• Entire system is completely protected from sample arcs, regardless of module or sample used

• Expanded safety, with charges automatically diverted safely to ground whenever the circuit is interrupted during pulse delivery.

The Gene Pulser II unit may be used with either of two new types of accessory modules. For electroporation of bacteria and yeast, use the Pulse Controller II or Pulse Controller PLUS mod­ule. For electroporation of mammalian cells and embryonic tissue, use the Capacitance Extender II or Capacitance Extender PLUS module.

Specifications

Gene Pulser II System

Input voltage

100/120 V RMS, 50/60 Hz

220/240 V RMS, 50/60 Hz

Input current

15 amp RMS

Maximum output voltage and current

2,500 V at 125 amp peak (normal load); limited to 1,500 A during arc.

Output waveform

Pulse Trac exponential decay with RC time constant dependent on sample and capacitor selected

Output voltage adjustment

50-2,500 V range (depending on the capacitor) with 10 V adjustment precision for the high voltage range and 2 V for the low-voltage range (50-500 V).

Ambient operating environment

Temperature 0-35°C

Humidity 0-95% without condensation

Regulatory

Passes requirements of IEC 1010. In addition, the system passes requirements for FCC, Class A.

Dimensions

34 x 31 x 19 cm

Weight

10.41 kg

Part of labexchange logo