BioMerieux Vitek 2
Objektnummer | B00018817 |
---|---|
Seriennummer | 018817 |
Nome oggetto | BioMerieux Vitek 2 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: BioMerieux
model: Vitek2
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Specifications
Dimension VITEK® 2 VITEK® 2 XL
---------------------------------------------------------------------------------
Height 67 cm (26.3 in.) 67 cm (26.3 in.)
Width 100 cm (39.4 in.) 140 cm (55.1 in.)
Depth 71 cm (27.7 in.) 71 cm (27.7 in.)
Mass
Mass Approximately Approximately
110 kg (240 lb.) 145 kg (320 lb.)
Environment
Note: The specifications below apply to both the VITEK® 2 and the VITEK® 2 XL.
Indoorusage
Do not install in direct sunlight
Benchtopshould be level within 2°
Minimum of 5 cm (2 in) clearance on all sides for adequate ventilation; 50 cm (20 in) above
Minimum installation altitude: Â100m
Maximum installation altitude: 2000m
Ambient room temperature: 20 °C to 30 °C
Shipment and storage temperature: Â20 °C to +50 °C
Relative humidity: 20% to 80% non-condensing
Pollution degree 2 in accordance with IEC 664
OvervoltageCategory II per IEC 664
Electrical Characteristics
VITEK® 2 VITEK® 2 XL
---------------------------------------------------------------------------------------------------------------------------
Input voltage 200/240 VAC at 50/60 Hz 200/240 VAC at 50/60 Hz
100/120 VAC at 50/60 Hz 100/120 VAC at 50/60 Hz
Maximum input current 4 amps @ 120 VAC or 5 amps @ 120VAC or
2 amps @ 240 VAC 2.8 amps @ 240 VAC
Nominal input current 1.5 amps @ 120 VAC or 2.75 amps @ 120 VAC or
0.75 amps @ 240 VAC 1.75 amps @ 240 VAC
Power 150 watts nominal, 200 watts nominal,
471 watts peak 569 watts peak
Heat 512 BTU/HR (nominal) 682 BTU/HR (nominal)
Power cord Detachable 3-wire with Detachable 3-wire with ground,
perIEC 227 or IEC 245 per IEC 227 or IEC 245
Optical Characteristics
Note: The specifications below apply to both the VITEK® 2 and the VITEK® 2 XL.
Transmittance Optics
Emission wavelengths: 660 nm, 568 nm, 428 nm LED
Percent transmission range: 30% to 100% ± 10%
General Characteristics
Note: The specifications below apply to both the VITEK® 2 and the VITEK® 2 XL.
Cassette
Capacity, cassettes: 4 cassettes maximum
Capacity, cards: 15 cards per cassette
Dispenser
Dispensing volume: 2.33 ÂÂ 2.63 mL
Capacity: 1000 mL, user replaceable
Pipettor
Dispensing volume: 60 µL to 300 µL ± 5% or ± 5 µL, whichever is greater
Pipettordrum capacity: 330 pipette tips minimum, user replaceable
Vacuum (Filler)
Minimum level: 0.89 PSIA ± 0.06 PSIA
Sealer
Mechanical: stub length 0.025 mm to 2.5 mm
Incubator
Temperature: 35.5 °C ± 1 °C average
Capacity: 60 cards per Incubator