Bioblock Scientific 8005
| Objektnummer | B00018652 |
|---|---|
| Seriennummer | 018652 |
| Nome oggetto | Bioblock Scientific 8005 |
| Stato | Archived Product |
Gruppo prodotti: Termostati / Criostati
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Bioblock
model : Scientific 8005
annotation : Dokumente engl .
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Description of Circulating
Standard controller refrigerated and heating circulating baths are designed to provide precise temperature control of fluids for closed loop circulation to external equipment or to be used as a stand alone bath. The reservoir may be used for immersing samples while the unit is connected to an external device. All wetted parts are corrosion resistant 300 series stainless steel. Models are equipped with various size reservoirs and refrigeration capacities.
Specification Chart - Circulating Baths
Model Type Temperature Reservoir Amps@ Amps @
Range Capacity 120v 60Hz 240v 50Hz
----------------------------------------------------------------------------------------------------------------------------------------
9005 Refrig /Heat -20°C to 150°C 6L 10a 5a
9105 Refrig /Heat -20°C to 150°C 6L 10a 5a
9505 Refrig /Heat -30°C to 150°C 13L 12a 6a
9605 Refrig /Heat -25°C to 100°C 28L 12a 6a
9705 Refrig /Heat -40°C to 150°C 13L 12a 6a
8005 Heat Ambient+5°C to 150°C 6L 8.8a 4.4a
8105 Heat Ambient+5°C to 150°C 13L 8.8a 4.4a
8205 Heat Ambient+5°C to 150°C 8L 8.8a 4.4a
Specifications for all Models
Temperature Stability ± .05°C Over Temp Protection Yes
Readout Accuracy + .5°C Low Liquid Protection Yes
Heater 1000 Watts Pump Speeds 7 & 15L/Min
Circulating
On circulating baths, the pump inlet and outlet are internally threaded with fernale 1/4 inch NPT to allow use of barbed tubing adapters or hard plumbing. Or, you can slide 1/2 inch (13mm) ID tubing over each pipe and hold it in place with a hose clamp.
Select tubing and fittings that are compatible with bath fluid and temperature range. If the pump inlet and outlet are not used for external circulation, for best results connect the inlet and outlet pipes with a short length of insulated tubing. Or, plug the pipes with male nylon plugs (supplied) or with metal plugs (not supplied) for high temperature use.
The nylon barbed tubing adapter fittings supplied are for applications from -40°C to 93°C. Brass, stainless steel or Teflon® fittings are recommended for applications above 93°C.
Quick connectors are not recommended as they typically restrict flow rate.
Immersion CircuIator
Description of Immersion Circulator
The immersion circulator is not supplied with integral reservoir and is primarily for heating and circulating fluid in a reservoir supplied by the user Although not designed for closed loop circulation, it can be used for this purpose. Operation of the controller is the same as the reservoir units.
Specification Chart - Immersion Circulator
Model Type Temperature Reservoir Amps Amps
Range Capacity 120v 60Hz 240v 50Hz
----------------------------------------------------------------------------------------------------------------------------------------
7305 Immersion/Heat Ambient+5°C to 150°C* Not Built In 9a 4.5a
*See Section 1.4.5 - Attainable Temperatures for Immersion Circulator. Accessory cooling coil must be used for temperatures closer to ambient. Auxiliary refrigeration can be used for temperatures at or below amb ient.
Specifications for all Models
Temperature Stability . +/- 05°C Over Temp Protection Yes
Readout Accuracy +/- 5°C Low Liquid Protection Yes
Heater 1000 Watts Pump Speeds 7 & 15L/Min
Set Up of Immersion Circulator
Clamp the immersion circulator to the side of a tank (user supplied) or to a support rod adjacent to a tank. Be especially careful to maintain an adequate depth to fully immerse the heater and pump outlet nozzle. When using a plastic tank, position the circulator so the heater does not contact the side of the tank. The rotatable pump outlet nozzle should be pointed along one side of a reservoir wall to produce the best fluid agitation.
AttainableTemperatures for Immersion Circulator
An immersion circulator can be used with reservoirs of varying size and shape, as well as with different types of fluid. The following chart indicates the maximum temperature that can be achieved, dependent on the reservoir's size and fluid's surface area:

lmmersion Circulator Fluid Connection to External Apparatus
The immersion circulator does not have inlet and outlet fittings. However, 1/2inch I.D. tubing may be fastened with a hose clamp to the rotatable pump outlet nozzle and connected to the inlet of external apparatus. Tubing from the external apparatus outlet must return the fluid back into the reservoir.
Operation - All Models
Set Up
Location
Locate your circulator on a level surface free from drafts and direct sunlight. Do not place it where there are corrosive fumes, excessive moisture, high room temperatures, or excessively dusty areas. Refrigerated circulators must be four inches minimum away from walls or vertical surfaces so air flow is not restricted. Avoid voltage drops by using properly grounded power outlets wired with 14 gauge or larger diameter wire and if possible, be close to the power distribution panel. The use of extension cords is not recommended, this will avoid low line voltage problems.