Archivio

Bioblock Scientific 45008

Seriennummer: 018636
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00018636
Seriennummer 018636
Nome oggetto Bioblock Scientific 45008
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

manufacturer :       Bioblock

model :                   Scientific 45008

annotation :           Dokumente engl .

 

 

 

BIOBLOCK HYBRIDIZATION OVEN

MODEL: 45008

 

 

Controls Overview

 

Power

The main power ON/OFF switch controls all power to the unit. It must be on before any systems are operational, including control circuitry. A light in the switch is activated when on.

Set Temperature

This control consists of the Up/ Down buttons and the digital display.

Heating When Lit

This light is on continuously when the unit is heating to set point and is blinking when controlling temperature at or near set point.

Rotate

This switch controls the rotisserie. This is a three position switch: ON/OFF/JOG . The pilot light, marked Rotating. When Lit, will be activated when this switch is in the ON or JOG position.

Rotational Speed Control

This controls rotisserie speed from 0 to 15 RPM.

 

 

 

Operation

 

WARNING; Temperatures in excess of 70°C can cause breakage of hybridization bottles. Do not run this chamber at temperatures above 70°C when bottles are in use. If the chamber temperature rises above 70°C and bottles are in the chamber, DO NOT OPEN THE OUTER DOOR. Turn the chamber power switch off and allow the chamber and bottles to cool below 70°C before opening the outer door.

 

Push power switch to the ON position.

 

Set Temperature Control

Enter desired set point temperature. To enter set point mode on the control, press either the Up or Down button one time. The digital display will start to blink, going from bright to dim. While blinking, the digital display is showing the set point. To change the set point, use the Up and Down buttons. lf the buttons are not pressed for five (5) seconds, the display will stop blinking and will read the temperature of the unit. NOTE. This control contains an automatic Overtemperature Safety which is set 1°C above set point.

 

Rotisserie Operations

The rotate switch is a three position switch which controls the rotisserie. The rotisserie is ON when the switch is in the up position; the rotisserie is OFF when the switch is in the center position. The lower position of the switch allows the user to incrementally rotate (JOG) the rotisserie.

 

Rotisserie Speed RPM Control

This control allows the user to change the speed of the rotisserie. Turning the knob clockwise allows the rotisserie to go faster. The range of this control is from 0 to 15 RPM.

 

 

 

 