Biacore S 51
Objektnummer | B00012693 |
---|---|
Seriennummer | 012693 |
Nome oggetto | Biacore S 51 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Manufacturer Biacore
Model S51
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Specifications
Information provided |
Kinetic and affinity data (KD, ka, ka, R50), binding level ranking, association and dissociation level ranking, binding level vs. stability (binding strength), specificity |
Data presentation |
Result tables, result plots and real time monitoring of interactions |
Throughput |
Typically 200 samples/24 hours (Hit Selection) |
Automation |
24 hour unattended operation |
Sample type |
Low or high molecular weight compounds, e.g. in DMSO containing buttere. |
Molecular weight detection |
>100 Da (ligand and analytes dependent) |
Sample concentration |
Sub nM to mM sample concentrations |
Required sample volume per analysis |
30 - 370 µl (application dependent) |
Vial dead volume |
10 µl (for microplates supplied by Biacore) |
Target protein consumption |
Typically 5-20 µg per immobilization |
Compound consumption |
Typically 1 - 5 µg per determination |
Assay flow rate |
10, 30 or 90 µl/min |
Sample/reagent capacity |
One 384 well or one 96 well microplate + 33 reagent vials + 2 reagent bottles |
Analysis temperature |
4 - 45 °C (maximum 20 °C below ambient) |
Sample temperature |
From ambient temperature to 35 °C |
Sample refractive index range |
1.33.- 1.40 |
in-Iine reference subtraction |
Automatic |
Typical working ranges, kinetics: |
Association rate constant (ka) Up to 5 x 106 M-1s-1 (and higher for macromolecular analytes) Dissociation rate constant (kd) 10-4-1 s-1 (dissociation time limited to 1000 s)Affinity (KD from kd/ka) Typically 100 µM - 10 pM (analyte and target dependent) |
Flow cell configuration |
Two flow cells, each with two independent detection spots and an in-line reference |
Baseline noise |
Typically <0.1 RU (RMS) |
Baseline drift |
Typically <0.3 RU/min in ambient temperature range 15.35 °C |
Dimensions (footprint, excluding System Controller) |
600 x 620 x 690 mm (W x D x H) |
weight |
62 kg (137 Ibs) |
Power |