Becton Dickinson LSR II
Objektnummer | B00022094 |
---|---|
Seriennummer | 022094 |
Nome oggetto | Becton Dickinson LSR II |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: Becton Dickinson
model: LSR II
annotation: Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
BD TM LSR II is the first and only air cooled four-laser benchtop flow cytometer with the ability to acquire 10 or more colors. At the heart of the BD LSR II is the new digital acquisition system, sampling signals at 10 million times a second, providing increased detection and channel resolution per pulse, thus yielding more information per cell. BD digital software provides both online and offline compensation running in a Windows®- based environment. Configure your cytometer with fixed-alignment 488-nm, 633-nm, 405-nm, and 355-nm lasers. Each laser has a spatially separated beam spot. Light is transmitted by fiber optics to an innovative Octagon detector array with user-interchangeable reflective dichroics and optically matched bandpass filters that produce increased sensitivity. Multicolor experiments have now gotten easier by running them on the BD LSR II.
Specifications*
Performance
Fluorescence Sensitivity
Estimated detection limit is <200 molecules of equivalent soluble fluorescein (using Spherotech Rainbow RCP 30-5A particles).
Fluorescence Resolution
Coefficient of variation FL2-Area of <3%, full G 0 /G 1 peak for propidium iodide (PI)stained chicken erythrocyte nuclei
Fluorescence Linearity
Doublet/singlet ratio for CENs stained with PI = 1.952.05 detected off the 488-nm or UV laser
Forward and Side Scatter Sensitivity
Sensitivity enables the separation of fixed platelets from noise.
Forward and Side Scatter Resolution
Scatter performance is optimized for resolving lymphocytes, monocytes, and granulocytes.
Sample Acquisition Rate
>20,000 events/sec (2 x 10 7 cells/mL running at 60 µL/min)
Excitation Optics
Optical Platform
Fixed optical assembly
Kinematic beam steering
Lasers
20-mW; Coherent Sapphire 488-nm, air-cooled, argon-ion laser
25-mW; 405-nm Coherent VioFlame
20-mW; 635-nm JDS Uniphase HeNe
355-nm Lightwave Solid-State laser
Beam spot size
15 ±3-µm height and no greater than 75 ±15-µm width
Emission Optics
Optical Coupling
Quartz curvette is coupled to emission lens by refractive index-matching optical gel for optimum collection efficiency.
Fluorescence Detectors and Filters
Four fixed fiber apertures
(125-µm separation)
Ten fluorescence detectors
High-performance, high dynamic range photomultiplier and red‑sensitive photomultipliers with filters
Four wavelengths detected from the 488-nm laser:
515545 nm FITC
562588 nm PE
675715 nm PerCP Cy5.5 or PE-Cy5.5
750810 nm PE-Cy7
Two wavelengths from the 635-nm laser:
650670 nm APC
750810 nm APC-Cy7
Two wavelengths from the 325-nm laser:
395415 nm Indo-1 (Violet)
425475 nm DAPI or Hoechst
Two wavelengths from the 405-nm laser:
420460 nm Cascade Blue
505585 nm Alexa 430
Additional bandpass filters supplied:
663677 nm PE-Cy5
750810 nm PE-Cy7
515545 nm Indo-1 (Green)
Filters and mirrors are user changeable.
Signal Processing
Workstation Resolution
Five decades for peak detection: offset less than 1/10,000 of full scale
Data Acquisition Channels
Twelve acquisition channels with up to four time-displaced laser beams
18-bit data acquisition
262,144 linear channels displayed in a 5-decade logarithmic display
Fluorescence Compensation Networks
Inter- and intra-beam software- programmable resolution of 0.01%
Pulse Processing
Width and Area measurements available for all fluorescence parameters
Ratio measurements for intra-laser parameters (useful for calcium measurements)
Time
Time available correlated to any parameter
Channel Trigger
Triggering on any laser signal
Ability to create logical AND/OR of channel triggers
Ratio
Ratio measurements between any two parameters
Fluidics
General Operation
Front key panel provides three modes: RUN, STNDBY, and PRIME;
automatic standby mode conserves sheath fluid by stopping sheath flow when no sample tube is installed.
Sample Flow Rates
Three selectable flow rates
Regulated pressure difference between sheath and sample
Quartz Curvette
Internal cross-section is rectangular 430 x 180 µm; external surfaces are anti-reflection coated for maximum transmission of laser light.
Data Management System
Workstation
HP X4000 workstation or equivalent
Central Processing Unit (CPU)
Dual Intel Xeon processors
Memory
Data Storage
Nine-and 36-GB internal hard drive, internal drive with 250-MB removable disk storage space capacity, 3.5-inch floppy drive, CD-RW drive, tape drive
Networking
Ethernet
Monitor
Two 18-inch LCD monitors
Printer
Networkable color-inkjet printer
Data File Structure
Flow Cytometry Standard (FSC) 3.0 or 2.0