Beckman UV-24
| Objektnummer | B00007433 |
|---|---|
| Seriennummer | 007433 |
| Nome oggetto | Beckman UV-24 |
| Stato | Archived Product |
Gruppo prodotti: Fotometri / Spettrofotometri
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
These devices are intended for use by operators experienced with the methodology, during those parts of in vitro diagnostic enzymatic or quantitative or qualitative analysis procedures which require measurement of light transmission through reagents at wavelengths in the visible and ultraviolet regions of the electromagnetic spectrum.
The Model 24 is capable of measuring light at wavelengths from 340 to 700 nanometers (190 to 700 nanometers with optional deuterium source).
The Model 24 Spectrophotometer are double-beam, digital-reading or recording instruments which can make absorbance, concentration, percent transmission and differential absorbance measurements. Quantitative and qualitative analysis and reaction-rate studies are easily accomplished. Specialized techniques such as automatic sampling and batch sampling, are possible with addition of easily mounted accessories.
The Model 24 Spectrophotometer is housed in a compact case with front and rear panel controls, and a four-digit display. Major design features of the instrument include: one source (tungsten), monochromator, detector, large sample compartment, fixed slit, solid-state circuitry, a fixed aperture, 340 to 700-nanometer operating range, and readout in absorbance, concentration, and differential absorbance modes.
Specifications
MONOCHROMATOR
Single monochromator, filter-grating, 1200 lines/mm and blazed at 250 nm.
OPTICAL PRINCIPLE
Double-beam and single-beam.
WAVELENGTH RANGE
Model 24 Spectrophotometer: 340 to 700 nm.
WAVELENGTH PRESENTATION
Linear, digital counter.
WAVELENGTH ACCURACY
±0.5 nm.
WAVELENGTH REPEATABILITY
Better than 0.20 nm.
STRAY LIGHT
Model 24 Spectrophotometer: less than 0.1 % at 370 nm.
RESOLUTION
Model 24 Spectrophotometer: 4 nm.
SLITS
Model 24 Spectrophotometer: Fixed, 0.8 mm.
PHOTOMETRIC READOUT
Digital Display
Four-digit digital display, 0 to 2 A, or 0 to 8000 counts in concentration. In addition, 0 to 200%T an the Model 26.
Recorder
100-millivolts per absorbance unit or 100 millivolts per 100%T on the Model 26.
Differential
-0.3 A to +0.7 A with 1 A Pushbutton depressed (on Models 24 and 25).
BCD Connector
0 to 2 A or 0 to 8000 counts in concentration through 36-pin connector.
BCD OUTPUT
16-line BCD
-10 to + 8000 counts.
BCD PRINT OUTPUT
A positive true-open collector pulse, 20 microseconds wide, occurs 6 seconds after completion of sipper fill time.
DATA READY OUTPUT
0.5-millisecond positive pulse indicating data will remain valid for 0.25-second. Occurs approximately one-third of a second after receiving a convert input.
CONVERT INPUT
A ground true pulse of at least 50-microseconds duration. A new update is initiated on trailing edge of pulse.
BCD DISPLAY HOLD INPUT
A false logic level or a ground will inhibit the updating of the output register while data are being taken. This signal should be used only if data are being taken asynchronously.
PHOTOMETRIC ACCURACY
0.5% of reading or 0.001 A, whichever is larger.
PHOTOMETRIC REPEATABILITY
0.25% of reading or 0.001 A, whichever is larger.
RECORDER SCALES
0.1 A, 0.25 A, 0.5 A, 1.0 A, and 2.0 A fullscale; and 10%, 25%, 50%. 100% and 200%T fullscale on Model 26.
SCANNING SPEEDS
100, 50, 20, and 5 nm/min selectable on accessory recorder unit.
CHART SPEEDS
.1, .2, .5, 1, 2, 5, and 10 in/min.
0 A LINE
±0.009 A maximum deviation (including noise) from 200 to 700 nm.
BASELINE STABILITY
Double-beam better than 0.0004 A per hour at zero A.
APPROXIMATE WEIGHT
Normal: 70 pounds net.
Shipping: 85 pounds.
OVERALL DIMENSIONS
24 inches long x 16 inches deep x 14 inches high.
POWER REQUIREMENTS
120/240 volts (±10%), 50/60 Hz. Two amperes at 120 volts and one ampere at 240 volts.