Beckman HPLC
| Objektnummer | B00005633 |
|---|---|
| Seriennummer | 005633 |
| Nome oggetto | Beckman HPLC |
| Stato | Archived Product |
Gruppo prodotti: HPLC Sistemi
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Kommentar: Dokumente für IDNR 9744
System Gold HPLC
bestehend aus:
· Rheodyne Inj.-ventil 9725i
· DynaLoop
· Pumpenmodul 126
· DAD 168
· BioFrac Fraction Collector
· Unichromat 1500
· PC/Workstation V5.00
· Monitor, Drucker
Ø Rheodyne Inj.-ventil 9725i
DESCRIPTION
Models 7725(i), 9725(i), 3725(i)-038, 3725(i), and 9125 are six-port sample injection valves in which the sample is loaded through a built-in needle port in the front of the valve. Models 7725(i) and 3725(i)-038 are the stainless steel versions, and Models 9725(i), 3725(i), and 9125 are the PEEK versions.
The 'i" version of each model includes a built-in position sensing switch.
LOADING BY SUCTION
The two preceding methods expose the sample to the metal needle of the loading syringe. Metal can be completely avoided by using a syringe to suck sample into the loop.
The steps are as follows:
a) In LOAD, dip the tube attached to Port 6 into the sample.
b) Insert an empty syringe into the needle port and suck up sample into the loop. Alternatively, use the Suction Needle Adapter (P/N 9125-076, not supplied).
c) Leave the syringe in position and turn to INJECT.
The metal needle of the syringe will contact the sample if an excess of sample is drawn into the syringe, but this excess sample is external to the sample loop and will not be injected. The syringe can be used many times before it needs to be emptied.
To load the loop with all of the available sample, the loop should be at least four times the volume of sample loaded. The loop is first filled with mobile phase via the dip tube, then the whole sample is drawn into the dip tube and loop, followed by more mobile phase. The sample is now sandwiched between two zones of mobile phase in the loop.

Loading by suction using the Suction Needle Adapter.
Ø DynaLoop
DynaLoop Sample Loop Description
The DynaLoop Sample Loop is a large-volume sample injection loop for use with the BioLogic System. Available in 25 ml and 90 ml sample capacities, the DynaLoop can be used with either the manual V7-3 or automated AV7-3 injection valve.
Operation
The DynaLoop consists of five major components (Figure 1):
Sample end assembly
Buffer end assembly
Glass tube graduated in 1 ml increments
Sliding seal assembly
Protective plastic jacket

DynaLoop 25 and DynaLoop 90 Sample Loops
Ø Pumpenmodul 126
Das Pumpenmodul 126 für Gradientenbetrieb fördert 0,001 bis 10 ml/min.
Das Einkolben Design mit elektronischer Echtzeit Kompressibilität-Kompensation gewährleistet konstanten und pulsfreien Fluß, unabhängig von Laufmittel und Druck. Die Hinterkolbenspülung verhindert das Auskristallisieren von Salz.
Im Modul 126 integriert befindet sich der doppelstufige dynamische Mischer für hochdruckseitige Gradientenformung.
Programmierbare Eluentenselektoren ermöglichen die automatische Lösungsmittelauswahl aus 4 Vorlagen pro Pumpe.
Ø DAD 168
Der Diodenarray-Detektor Modell 168 bietet folgende Spezifikationen:
- 512 Dioden
- Analytische Standard-Flußzelle:
11 ul Zellvolumen, 10 mm Weglänge
- Auf Wunsch semi-präparative Flußzelle:
2 mm Weglänge
- Wellenlängenbereich: 190 - 600 nm
- Wellenlängengenauigkeit: ± 1 nm
- Bandbreite: Variabel von 4 nm bis zum gesamten Wellenlängenbereich
- 2 Datenkanäle + 1 Referenzkanal
- Basislinienrauschen: kleiner 1 x 10 (-4) AU
- Drift: kleiner 2 x 10 (-3) AU/h
- Meßbereich: 0.001 bis 1.5 AUFS
- Variable Rise-Time: 0 - 5 sec
- Datenrate: 1, 2, 4, 8 oder 16 Hz
- Autozero
- Peakerkennung für die Scan-Funktion bzw. zur Steuerung eines Fraktionssammlers
- Scan-Arten: in frei wählbaren Intervallen, am Peakmaximum, zur Reinheitskontrolle,bei Detektion einer Verunreinigung
- Scanrate: 0.5 bis 16 Hz
- Spektrale Bandbreite: kleiner 4 nm
- Real-Time Scan während der Datenaufnahme
- Software zur Real-Time Peakreinheitsbe-. stimmung: ein graphisches Symbol unter dem Chromatogramm zeigt die Anzahl der Verunreinigungen an
- Pro PC kann nur 1 Diode-Array Detektor 168 betrieben werden
- bestehend aus:
Diode-Array Detektor 168
Scan-Graphik Software
Ø BioFrac Fraction Collector
Physical Description



|
Rack ID |
Rack Description |
Rack Capacity |
Format Columns x Rows |
Tubes Per Rack (Total) |
|
F1 |
Holds 12-13 mm diameter tubes up to 150 mm in height |
2 racks |
6 x 15 |
90 (180) |
|
Ice bath/ microplate rack |
Ice bath for 13 mm diameter tubes. This rack also serves as a holder for 12-, 24-, 48-, and 96-well microplates and microtiter tubes that adhere to the SBS standard format. |
1 rack |
10 x 12 |
120 |
Ø Unichromat 1500
Das Gerät dient ausschließlich zur Lagerung von Lebensmittelprodukten. Die Produkte sind unter Beachtung der aufgeführten Ladekapazität und unter Gewährleistung der einwandfreien Luftzirkulation im Geräteinnern zu lagern.
Ladekapazität in mm L:530 H: 1200 P: 650
Öffnungsmaße eines Gerät-Kühlfachs: L: 600 H: 1500