Beckman GenS
Objektnummer | B00012599 |
---|---|
Seriennummer | 012599 |
Nome oggetto | Beckman GenS |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Beckman
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.
INTENDED USE
The COULTER® GEN STM System, Figure 1.1, is a quantitative, automated hematology analyzer For In Vitro Diagnostic Use in clinical laboratories. The GENS System provides automated complete blood count, leukocyte differential and Reticulocyte analysis.
The purpose of the GENS System is to separate the normal patient, with all normal system-generated parameters, from the patient who needs additional studies of any of these parameters. These studies might include further measurements of cell size and platelet distribution, biochemical investigations, manual WBC differential or any other definitive test that helps diagnose the patient's condition.
PHYSICAL SPECIFICATIONS
Dimensions
Unit Height* Width* Depth* Weight
Analyzer 35.6 cm 99.1 cm 38.1 cm 49.9 k
(14 in.) (39 in.) (15 in.) (110 Ib)
Diluter 50.8 cm 99.1 cm 55.9 cm 54.4 k
(20 in.) (39 in.) (22 in.) (120 Ib)
Power 63.5 cm 38.1 cm 66.0 cm 56.7 k
Supply
(25 in.)
(15 in.)
(26 in.)
(125 Ib)
* ±5.1 cm (2 in.)
Power
Input
Power Supply: 90 - 264 Vac, 47 - 63 Hz
Workstation: 90-135 Vac, 47-63 Hz or 180-265 Vac, 47-63 Hz
Consumption
1650 W (5500 BTU/h) maximum
Installation Category: per IEC 1010-1, Category II
Temperature
Ambient operating range for patient samples: 15.5 to 32°C (60 to 90°F)
Humidity
0 to 95% without condensation
Sample Stability
CBC/Diff Parameters
Stored at room temperature, up to 24 hours after collection
Stored between 2 and 8°C (35.6 and 46.4°F), up to 48 hours
after collection
Reticulocyte Parameters
Stored at room temperature (23.9°C or 75°F), up to 24 hours
after collection
Stored between 2 and 8°C (35.6 and 46.4°F), up to 72 hours
after collection
Sample Storage
Room temperature (23.9°C, 75°F) up to 24 hours
Sample Type
Anticoagulated human whole blood
Recommended Anticoagulant
K2EDTA or K3EDTA
COULTER ® Gen-S Hematology Analyzer
The Beckman-Coulter GEN-S, a new generation hematology analyzer capable of providing a complete blood count, a five-part differential leukocyte count, and a reticulocyte count.
The Gen-S provides automated reticulocyte counts from closed vial sample aspiration to result transmission, and permits you to enjoy significant productivity gains. Compared to manual methods, each automated count saves up to 10 minutes of valuable operator time.
In addition, automated counts give you the assurance of greater accuracy.
The Gen-S represents a new generation fully automated hematology analyzer that can provide the laboratory with up to 34 blood count parameters: a complete blood count (CBC), a five-part differential leukocyte count (DLC), a complete reticulocyte count, and an automated CD4/CD8 count. Moreover, when abnormal leukocytes are present, the system generates different flags.
System Description
The Gen-S analyzer uses the Coulter Volume, Conductivity, Scatter (VCS) technology to probe hydrodynamically focused cells. Volume measurement is performed using the Coulter principle of electrical impedance. The high frequency conductivity provides information about cell size, internal structure, and density. A helium-neon laser and a multiple-angle light scatter provide information about a cell's internal structure, granularity, and surface morphology. VCS technology has proven effective on the Coulter STKS and MAXM analyzers. The GEN-S refines this technology through the use of the IntelliKinetic (Beckman trademark technology) application. This hardware and software system intelligently manages variations in the ambient laboratory temperature through automatic adjustments of reagent reaction temperature, exposure time, and delivery volumes.
Enhancement in instrument electronics works with the IntelliKinetic application to provide better data signals for the system algorithm to analyze. Collected data are analyzed by Coulter AccuGate software (version EASE 2, (Beckman trademark technology)), which contains adaptive statistical tools that assist in delineating overlapping populations including new suspect flags
(e.g., Ly blast for Lymphoblast suspect) and additional "research use only" parameters. DLC data can be presented in a multidimensional format.
· A limited grouping of just four reagent packs that handle all your routine hematology testing needs
· Three independent counts for WBC, RBC and Plt
· Extended counting for cytopenic samples
· Pulse editing technology for accurate cell volumes
· High resolution histograms using 256 channels
· Log-fitting platelet algorithm eliminates RBC interference
· Sweep flow technology prevents recirculating red cells and improves platelet accuracy
· Radio frequency (RF) energy penetrates the cell, information is gathered about the cell size and internal structure
Slidemaker GENS SM TM
The COULTER GEN S SM TM SlideMaker is intended for use as an optional peripheral to the COULTER GEN S TM System. The Slide maker creates a blood smear on a clean microscope slide using a segment of the blood sample aspirated by the GEN S System.
Physical Specifications
(See the GEN S System specifications for general specifictions that apply to both the GEN S System and the SlideMaker.)
Specification that apply only to the SlideMaker are listed here:
Dimensions:
Height: 45,7 cm (18in)
Width: 61,0 cm (27in)
Depth: 61,0 cm (24in)
Weight: 45,8 kg (100lb)
Power:
Input: 90-264 Vac
48-62 Hz
Consumption: 350 W (Btu) maximum
Recommended Reagents
The GEN S SM SlideMaker uses the diluent and cleaning agent from the GEN S System:
▪ ISOTON®III diluent
▪ COULTER CLENZ® celaning agent
Sample Volume
Aspirated Volume: 250 µL maximum
Dispensed Volume: 4µL ±0,5 L
Slidestainer GenS ST TM
Working in conjunction with the GENS and GENS SMTM SlideMaker, the GENS STTM SlideStainer is a programmable laboratory device that is capable of delivering a variety of fixatives, stains, buffers and rinse solutions to whole blood films prepared on glass microscope slides. The flexibility of the GENS SlideStainer allows for the adaptation of a large range of currently popular stain methodologies depending upon the preferences of the user.
The GENS SlideStainer contains five baths with automatic reagent refill capabilities and a sixth warm air bath for the drying of the stained film following the staining process. Blood films produced by the GENS SlideMaker and contained in metal carriers are automatically transferred to the GENS SlideStainer by a robotic arm to the fixative, staining, buffer, rinse and drying positions at programmable intervals. Following the drying sequence the slide filled carriers are removed to a location on the stainer to await removal by the laboratorian
The stained whole blood film produced by the GENS SlideStainer, when inspected microscopically, can be used to help determine the hematological status of a patient. A stained blood film, in addition to allowing for the differentiation of white cells, facilitates the characterization of red cells and platelets as well as the identification of blood component anomalies.
Dimensions:
Height: 48.26 cm (19in.)
Width: 58.42 cm (23in.)
Depth: 71.2 cm (28in.)