Beckman-Coulter LH500
Objektnummer | B00018153 |
---|---|
Seriennummer | 018153 |
Nome oggetto | Beckman-Coulter LH500 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Beckman-Coulter
model : LH500
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
High-Volume Performance in a Compact Design The COULTER® LH 500 Hematology Analyzer helps increase productivity, enhances linearity, improves diff flagging and reduces false positive flaggingall in a compact design that fits your needs and your limited lab space. Plus, it offers advanced VCS technology, providing the greatest sensitivity, specificity and efficiency in white cell differential analysis. |
Features
Increased Efficiencies Help You Manage Your Workload
Reduce repeat testing and save time with expanded linearity for WBC and Platelt counts
Improved flagging reduces review rate
Standardize lab processes across all shifts with user-defined decision rules
Save time with continuous automated sample loading for complete walkaway operation
Integrated Solutions Expand Your Labs Capabilities
Simplify supply ordering with reagents interchangeable between all LH series models
Eliminate additional technologist training with a common user interface
Common LH series core technologies provide closest correlation of results between instruments.
LH series data management capabilities include full decision support
Easy-to-use Windows-based software
Save valuable lab space with a compact design that complements existing instruments
Run STAT samples with minimal interruption of routine workflow
· |
Method and Technologies
CBC Analysis & Hgb
· Coulter Principle: counting and sizing
· Triplicate counting
· Coincidence correction
· Pulse editing
· Sweep flow
· Extended platelet counting
· Hemoglobin method equal in accuracy to reference method
· LH Series Diluent and
COULTER ® LYSE S ® III diff reagent system
5-Part Differential Analysis
· VCS Technology
· LH Series reagent system
·
Retic Analysis
· VCSTM Technology
· COULTER ® ReticPrepTM reagent system (New Methylene Blue)
·
26 Parameters
WBC RBC PLT RETIC #
NE# HGB MPV RETIC %
NE% HCT PCT* IRF
LY# MCV PDW* MRV
LY% MCH
MO MCHC
MO% RDW
EO#
EO%
BA#
BA%
* For Research Use Only. Not for use in diagnostic procedures.
Sample Size
· 185 μ L whole blood, closed vial sampling
· 125 μ L whole blood, open vial sampling
· 50 μL whole blood, predilute mode
·
Barcode Symbology
Positive Barcode ID
· Codabar
· NW 7
· Code 39 ®
· Code 128
· Interleaved 2-of-5
·
LH 500 Workstation/Data Management
· Windows 2000 operating system
· Database capacity: 20,000 sets of results, graphics and listmode files
· User-defined flagging
· Archive and transmit patient and QC to host computer
· Decision rules criteria
Quality Control Management
· Unlimited control files with unlimited runs on each file
· Control and user-defined flagging
· Upload and download information from a diskette
·
Improved Linearity/Operating Ranges
Parameter
WBC 0.0 200.00 x 10 3 cells/ μ L 0.00 300.0 x 10 3 cells/ μ L
RBC 0.0 7.00 x 10 6 cells/ μ L 0.0 9.99 x 10 6 cells/ μ L
HGB 0.0 25.0 g/d L 0.0 99.9 g/dL
PLT 0.0 2,000.0 x 10 3 cells/ μ L 0.0 3500 x 10 3 cells/ μ L
Parameter Reportable Ranges Operating Range
MCV 50.0 150.0 fL 0.0 999.9 fL
Diff% 0 100% 0 100%
Diff# 0.00 200.00 x 10 3 cells/ μ L 0.00 300.00 x 10 3 cells/ μ L
RET% 0.00 30% 0.00 100.0%
RET# 0.00 0.7900 x 10 6 cells/ μ L 0.0000 999.9 x 10 6 cells/ μ L
Precision
Parameter @ Approximate Level Limit
WBC 4.0 15.0 x 10 3 cells/ μ L ≤2.5% CV
RBC 3.00 6.0 x 10 6 cells/ μ L ≤2.0% CV
HGB 12.0 18 g/dL ≤1.5% CV
MCV 80 100 fL ≤2.0% CV
RDW 12 15% ≤2.5% CV
PLT 200 500 x 10 3 cells/ μ L ≤5.0% CV
MPV 7 12 fL ≤3.0% CV
NE% 50 60% 2SD ≤3.0
LY% 25 35% 2SD ≤3.0
MO% 5 10% 2SD ≤2.0
EO% 2 5% 2SD ≤1.0
BA% 0.5 1.5% 2SD ≤1.0
RET % <1.00% 1 SD ≤0.23 or 23.0% CV
RET % 1.00 4.00% 1 SD ≤0.23 or 17.0% CV
RET % 4.01 15.00% 1 SD ≤0.68 or 15.0% CV
Accuracy Mean Difference % using
Parameter Mean Difference LH 750 Hematology Analyzer
WBC 0.00 100.0 ±0.2 3.5%
100.1 200.0 N/A 12.0%
RBC ±0.05 2.0%
HGB ±0.2 3.0%
MCV N/A 2.0%
PLT ±10 7.0%
MPV N/A 5.0%
Lymphocyte ±1.5
Monocyte ±1.5
Neutrophil ±2.0
Eosinophil ±0.5
Basophil ±0.5
RET
Both requirements must be met.
Dimensions/Weight
Height Width Depth Weight
Anal yzer 84.84 cm 61.5 cm 69.85 cm 94.5 kg
(33.4 in) (25.1 in) (27.5 in) (210 lb)
Computers 43.18 cm 19.7 cm 47.6 cm 9.7 kg
(17.0 in) (7.75 in) (18.75 in) (21.5 lb)
LCD Display 41.9 cm 40.4 cm 19.6 cm 7.34 kg
(16.5 in) (15.9 in) (7.7 in) (16.3 lb)
Temperature, Ambient Operating
18° 29°C (65 85°F)
Humidity
0 95% non-condensing
Throughput
Up to 75 samples/hour in Automatic mode