Beckman 160
| Objektnummer | B00015319 |
|---|---|
| Seriennummer | 015319 |
| Nome oggetto | Beckman 160 |
| Stato | Archived Product |
Gruppo prodotti: HPLC-Detectors
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
model: 160
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
SPECIFICATIONS
Optical System
Type Double-beam with interference filter.
Light source Mercury lamp, standard; zinc or cadmium lamp, optional.
Wavelengths 254 nm, standard; 10 other wavelengths from 214 nm through 546 nm available as options (see Table 2-1).
Flow Cell
Volume 18.5 µL (illum. vo!.with H20),
10-mm-path sample cell;
referencecell operated dry.
Liquid pressure 500 psimax.
Absorbance
Range
(preset) 001, .002, .005, .01, .02, .05, 0.1,
0.2, 0.5, 1 and 2 AU full scale (10 mV recorder).
Time Constants
(preset) 0, 0.1, 0.5, and 1 sec.
Linearity 1 5% up to 1 AU and 3% to 1.5
AU at 254 nm.
Noise 2 X 10-5AU peak to peak at 254 nm with a time constant of 0.5 sec or greater and flow rate of 1 mL/min of methanol.
Drift 1 X 10-4AU per hour max., at constant temperature, with flow rate of 1 mL/min of methanol.
Recorder
Output 10 mV full scale range, 0.65 V max.
Auto Zero Automatic baseline zero correction up to 1.8 AU,
implementedby single-key entry or external contactclosure input.
Event Marker Negative spike anrecorder trace, implemented by singlekey entry or externai contactcIosure input.
Control
Outputs Contact-closure outputs for peak detector, baseline detector, detector status, and mark.
Memory
Protection 45-minute battery backup.
Recharge time 8 hours.
Input Power Requirernents
Voltage 90-130 VAC or 198-264 VAC,
50/60 Hz, single phase
Power 90 W (nominal)
Size
Detector unit 12 in.W, 71/8 in.H, 15 in.D
30.5 cm W, 18.1 cm H,
38.1 cm D
Minicontroller 71/2 in.W, 21/2 in.H,4in. D.
19.0 cm W, 6.3 cm H, 10.2 cm D.
Weight
Detector unit 27 lb.
12.25 kg.
Minicontroller 1 lb.
. 45 kg.